Validity and reliability of a novel device for bilateral upper extremity functional measurements

Chueh Ho Lin, Li Wei Chou, Shun Hwa Wei, Fu Kong Lieu, Shang Lin Chiang, Wen Hsu Sung

研究成果: 雜誌貢獻文章

4 引文 (Scopus)

摘要

Background and objective: This study was designed to establish the validity and reliability of a new device that measures bilateral shoulder and elbow range of motion (ROM) and grip force performance in vivo. A further aim was to investigate the control of inter-limb grip force coordination during isometric force-maintenance tasks. Validity of the ROM and grip force measurements was examined using a validated clinical goniometer and standard weights. Subjects: Twenty-one healthy adults (six female, 15 male mean. ±. standard deviation age. = 23.05. ± 3.51) were recruited for this study. Design: All subjects were asked to perform tests to evaluate the validity and reliability of ROM, grip force maximum voluntary contraction (MVC) and coordination control measurements. Results: The ROM and grip force measurements were linearly correlated with criterion standards. For reliability testing, all of the intraclass correlation coefficient values were >0.99. The inter-limb grip force coordination control task showed that the force modulation timing during dominant-to-non-dominant hand transition was longer than the non-dominant-to-dominant hand transition (p<0.05). Conclusions: These results demonstrate that this device is valid and reliable when used to measure shoulder and elbow ROM and grip force of both hands. Isometric force-maintenance tasks also indicated changes in inter-limb grip force control.

原文英語
頁(從 - 到)315-323
頁數9
期刊Computer Methods and Programs in Biomedicine
114
發行號3
DOIs
出版狀態已發佈 - 2014
對外發佈Yes

指紋

Hand Strength
Reproducibility of Results
Upper Extremity
Force measurement
Articular Range of Motion
Equipment and Supplies
Goniometers
Advisory Committees
Force control
Extremities
Hand
Elbow
Modulation
Maintenance
Testing
Weights and Measures

ASJC Scopus subject areas

  • Computer Science Applications
  • Software
  • Health Informatics
  • Medicine(all)

引用此文

Validity and reliability of a novel device for bilateral upper extremity functional measurements. / Lin, Chueh Ho; Chou, Li Wei; Wei, Shun Hwa; Lieu, Fu Kong; Chiang, Shang Lin; Sung, Wen Hsu.

於: Computer Methods and Programs in Biomedicine, 卷 114, 編號 3, 2014, p. 315-323.

研究成果: 雜誌貢獻文章

Lin, Chueh Ho ; Chou, Li Wei ; Wei, Shun Hwa ; Lieu, Fu Kong ; Chiang, Shang Lin ; Sung, Wen Hsu. / Validity and reliability of a novel device for bilateral upper extremity functional measurements. 於: Computer Methods and Programs in Biomedicine. 2014 ; 卷 114, 編號 3. 頁 315-323.
@article{883bbe02c43749c7b11ed5a93a039295,
title = "Validity and reliability of a novel device for bilateral upper extremity functional measurements",
abstract = "Background and objective: This study was designed to establish the validity and reliability of a new device that measures bilateral shoulder and elbow range of motion (ROM) and grip force performance in vivo. A further aim was to investigate the control of inter-limb grip force coordination during isometric force-maintenance tasks. Validity of the ROM and grip force measurements was examined using a validated clinical goniometer and standard weights. Subjects: Twenty-one healthy adults (six female, 15 male mean. ±. standard deviation age. = 23.05. ± 3.51) were recruited for this study. Design: All subjects were asked to perform tests to evaluate the validity and reliability of ROM, grip force maximum voluntary contraction (MVC) and coordination control measurements. Results: The ROM and grip force measurements were linearly correlated with criterion standards. For reliability testing, all of the intraclass correlation coefficient values were >0.99. The inter-limb grip force coordination control task showed that the force modulation timing during dominant-to-non-dominant hand transition was longer than the non-dominant-to-dominant hand transition (p<0.05). Conclusions: These results demonstrate that this device is valid and reliable when used to measure shoulder and elbow ROM and grip force of both hands. Isometric force-maintenance tasks also indicated changes in inter-limb grip force control.",
keywords = "Grip force, Motor control, Range of motion, Upper extremity",
author = "Lin, {Chueh Ho} and Chou, {Li Wei} and Wei, {Shun Hwa} and Lieu, {Fu Kong} and Chiang, {Shang Lin} and Sung, {Wen Hsu}",
year = "2014",
doi = "10.1016/j.cmpb.2014.02.012",
language = "English",
volume = "114",
pages = "315--323",
journal = "Computer Methods and Programs in Biomedicine",
issn = "0169-2607",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Validity and reliability of a novel device for bilateral upper extremity functional measurements

AU - Lin, Chueh Ho

AU - Chou, Li Wei

AU - Wei, Shun Hwa

AU - Lieu, Fu Kong

AU - Chiang, Shang Lin

AU - Sung, Wen Hsu

PY - 2014

Y1 - 2014

N2 - Background and objective: This study was designed to establish the validity and reliability of a new device that measures bilateral shoulder and elbow range of motion (ROM) and grip force performance in vivo. A further aim was to investigate the control of inter-limb grip force coordination during isometric force-maintenance tasks. Validity of the ROM and grip force measurements was examined using a validated clinical goniometer and standard weights. Subjects: Twenty-one healthy adults (six female, 15 male mean. ±. standard deviation age. = 23.05. ± 3.51) were recruited for this study. Design: All subjects were asked to perform tests to evaluate the validity and reliability of ROM, grip force maximum voluntary contraction (MVC) and coordination control measurements. Results: The ROM and grip force measurements were linearly correlated with criterion standards. For reliability testing, all of the intraclass correlation coefficient values were >0.99. The inter-limb grip force coordination control task showed that the force modulation timing during dominant-to-non-dominant hand transition was longer than the non-dominant-to-dominant hand transition (p<0.05). Conclusions: These results demonstrate that this device is valid and reliable when used to measure shoulder and elbow ROM and grip force of both hands. Isometric force-maintenance tasks also indicated changes in inter-limb grip force control.

AB - Background and objective: This study was designed to establish the validity and reliability of a new device that measures bilateral shoulder and elbow range of motion (ROM) and grip force performance in vivo. A further aim was to investigate the control of inter-limb grip force coordination during isometric force-maintenance tasks. Validity of the ROM and grip force measurements was examined using a validated clinical goniometer and standard weights. Subjects: Twenty-one healthy adults (six female, 15 male mean. ±. standard deviation age. = 23.05. ± 3.51) were recruited for this study. Design: All subjects were asked to perform tests to evaluate the validity and reliability of ROM, grip force maximum voluntary contraction (MVC) and coordination control measurements. Results: The ROM and grip force measurements were linearly correlated with criterion standards. For reliability testing, all of the intraclass correlation coefficient values were >0.99. The inter-limb grip force coordination control task showed that the force modulation timing during dominant-to-non-dominant hand transition was longer than the non-dominant-to-dominant hand transition (p<0.05). Conclusions: These results demonstrate that this device is valid and reliable when used to measure shoulder and elbow ROM and grip force of both hands. Isometric force-maintenance tasks also indicated changes in inter-limb grip force control.

KW - Grip force

KW - Motor control

KW - Range of motion

KW - Upper extremity

UR - http://www.scopus.com/inward/record.url?scp=84899101091&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84899101091&partnerID=8YFLogxK

U2 - 10.1016/j.cmpb.2014.02.012

DO - 10.1016/j.cmpb.2014.02.012

M3 - Article

C2 - 24690377

AN - SCOPUS:84899101091

VL - 114

SP - 315

EP - 323

JO - Computer Methods and Programs in Biomedicine

JF - Computer Methods and Programs in Biomedicine

SN - 0169-2607

IS - 3

ER -