Ultrasound Guided Fine-Needle Aspiration Cytology for Women with Palpable Breast Lesions

貢獻的翻譯標題: 超音波導引下刺針抽吸應用在婦女可觸診到的乳房病灶上

研究成果: 會議貢獻類型海报

摘要

PURPOSE: We evaluated diagnostic accuracy of ultrasound guided fine-needle aspiration cytology (US-FNAC) for
women for women with palpable breast lesions.
MATERIALS AND METHODS: We reviewed 400 patients with palpable breast lesions with cytology specimens. Finally,
126 cases with US-FNAC and surgical specimens were enrolled. Diagnostic criteria for US diagnosis of breast
lesions were categorized as BI-RADS 0 to 5 according to American College of Radiology Breast Imaging Reporting
and Data System. The procedures were performed by two experienced radiologists. All specimens were stained with
Diff-Quik method and were interpreted by cytopathologists.
RESULTS: The diagnostic sensitivity, specificity and accuracy were 96.3%, 100%, 96.8%, respectively.
CONCLUSION: US-FNAC provides effective and accurate diagnosis for women with palpable breast lesions.
原文英語
出版狀態已發佈 - 三月 2012
事件THE 61ST ANNUAL MEETING OF THE RSROC - NTUH International Convention Center, Taipei, 臺灣
持續時間: 三月 24 2014三月 25 2014
https://www.rsroc.org.tw/annual/annualnews_detail.asp?id=42

會議

會議THE 61ST ANNUAL MEETING OF THE RSROC
國家臺灣
城市Taipei
期間3/24/143/25/14
網際網路位址

指紋

Fine Needle Biopsy
Cell Biology
Breast
Radiology
Information Systems
Ultrasonography
Sensitivity and Specificity

引用此文

Ultrasound Guided Fine-Needle Aspiration Cytology for Women with Palpable Breast Lesions. / Yao, Min Szu; Chen, Chia-Yuen; Chan, Wing P.; Liew, Phui-Ly; Chen, Chi-Long.

2012. 海報工作階段呈現於 THE 61ST ANNUAL MEETING OF THE RSROC , Taipei, 臺灣.

研究成果: 會議貢獻類型海报

Yao MS, Chen C-Y, Chan WP, Liew P-L, Chen C-L. Ultrasound Guided Fine-Needle Aspiration Cytology for Women with Palpable Breast Lesions. 2012. 海報工作階段呈現於 THE 61ST ANNUAL MEETING OF THE RSROC , Taipei, 臺灣.
@conference{bdabfc5e5c29469abcb3b3083839a99d,
title = "Ultrasound Guided Fine-Needle Aspiration Cytology for Women with Palpable Breast Lesions",
abstract = "PURPOSE: We evaluated diagnostic accuracy of ultrasound guided fine-needle aspiration cytology (US-FNAC) forwomen for women with palpable breast lesions.MATERIALS AND METHODS: We reviewed 400 patients with palpable breast lesions with cytology specimens. Finally,126 cases with US-FNAC and surgical specimens were enrolled. Diagnostic criteria for US diagnosis of breastlesions were categorized as BI-RADS 0 to 5 according to American College of Radiology Breast Imaging Reportingand Data System. The procedures were performed by two experienced radiologists. All specimens were stained withDiff-Quik method and were interpreted by cytopathologists.RESULTS: The diagnostic sensitivity, specificity and accuracy were 96.3{\%}, 100{\%}, 96.8{\%}, respectively.CONCLUSION: US-FNAC provides effective and accurate diagnosis for women with palpable breast lesions.",
author = "Yao, {Min Szu} and Chia-Yuen Chen and Chan, {Wing P.} and Phui-Ly Liew and Chi-Long Chen",
year = "2012",
month = "3",
language = "English",
note = "THE 61ST ANNUAL MEETING OF THE RSROC ; Conference date: 24-03-2014 Through 25-03-2014",
url = "https://www.rsroc.org.tw/annual/annualnews_detail.asp?id=42",

}

TY - CONF

T1 - Ultrasound Guided Fine-Needle Aspiration Cytology for Women with Palpable Breast Lesions

AU - Yao, Min Szu

AU - Chen, Chia-Yuen

AU - Chan, Wing P.

AU - Liew, Phui-Ly

AU - Chen, Chi-Long

PY - 2012/3

Y1 - 2012/3

N2 - PURPOSE: We evaluated diagnostic accuracy of ultrasound guided fine-needle aspiration cytology (US-FNAC) forwomen for women with palpable breast lesions.MATERIALS AND METHODS: We reviewed 400 patients with palpable breast lesions with cytology specimens. Finally,126 cases with US-FNAC and surgical specimens were enrolled. Diagnostic criteria for US diagnosis of breastlesions were categorized as BI-RADS 0 to 5 according to American College of Radiology Breast Imaging Reportingand Data System. The procedures were performed by two experienced radiologists. All specimens were stained withDiff-Quik method and were interpreted by cytopathologists.RESULTS: The diagnostic sensitivity, specificity and accuracy were 96.3%, 100%, 96.8%, respectively.CONCLUSION: US-FNAC provides effective and accurate diagnosis for women with palpable breast lesions.

AB - PURPOSE: We evaluated diagnostic accuracy of ultrasound guided fine-needle aspiration cytology (US-FNAC) forwomen for women with palpable breast lesions.MATERIALS AND METHODS: We reviewed 400 patients with palpable breast lesions with cytology specimens. Finally,126 cases with US-FNAC and surgical specimens were enrolled. Diagnostic criteria for US diagnosis of breastlesions were categorized as BI-RADS 0 to 5 according to American College of Radiology Breast Imaging Reportingand Data System. The procedures were performed by two experienced radiologists. All specimens were stained withDiff-Quik method and were interpreted by cytopathologists.RESULTS: The diagnostic sensitivity, specificity and accuracy were 96.3%, 100%, 96.8%, respectively.CONCLUSION: US-FNAC provides effective and accurate diagnosis for women with palpable breast lesions.

M3 - Poster

ER -