Simultaneous detection and quantitation of highly water-soluble herbicides in serum using ion-pair liquid chromatography-tandem mass spectrometry

Kuang Chuan Wang, Shih Ming Chen, Jung Fa Hsu, Sheaw Guey Cheng, Ching Kuo Lee

研究成果: 雜誌貢獻文章

53 引文 (Scopus)

摘要

We report the simultaneous screening of highly polar, water-soluble, and less-volatile herbicides, including glyphosate, glufosinate, paraquat, and diquat, in serum using liquid chromatography-mass spectrometry. The herbicides were separated by solid-phase extraction using a Strata-XC cartridge. A heptafluorobutyric acid solution was chosen as the mobile phase for ion-pair liquid chromatography. Mass spectrometry was used for analysis and was optimized for operation in the positive mode for all analytes. The serum specimens were screened for the presence of the herbicides at the following concentrations: 5 ng/mL for glyphosate, 2 ng/mL for glufosinate, 1 ng/mL for diquat, and 5 ng/mL for paraquat. This is the first report on the simultaneous detection of these compounds.

原文英語
頁(從 - 到)211-218
頁數8
期刊Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
876
發行號2
DOIs
出版狀態已發佈 - 十二月 15 2008

指紋

glyphosate
Ion chromatography
Liquid chromatography
Herbicides
Diquat
Tandem Mass Spectrometry
Liquid Chromatography
Mass spectrometry
Paraquat
Ions
Water
Mass Spectrometry
Serum
Solid Phase Extraction
Screening
phosphinothricin

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Cell Biology
  • Clinical Biochemistry

引用此文

@article{d197cb7edffa4699be689cd5db01aba2,
title = "Simultaneous detection and quantitation of highly water-soluble herbicides in serum using ion-pair liquid chromatography-tandem mass spectrometry",
abstract = "We report the simultaneous screening of highly polar, water-soluble, and less-volatile herbicides, including glyphosate, glufosinate, paraquat, and diquat, in serum using liquid chromatography-mass spectrometry. The herbicides were separated by solid-phase extraction using a Strata-XC cartridge. A heptafluorobutyric acid solution was chosen as the mobile phase for ion-pair liquid chromatography. Mass spectrometry was used for analysis and was optimized for operation in the positive mode for all analytes. The serum specimens were screened for the presence of the herbicides at the following concentrations: 5 ng/mL for glyphosate, 2 ng/mL for glufosinate, 1 ng/mL for diquat, and 5 ng/mL for paraquat. This is the first report on the simultaneous detection of these compounds.",
keywords = "Glyphosate, Herbicides, HFBA, Ion-pair, LC-MS, Paraquat",
author = "Wang, {Kuang Chuan} and Chen, {Shih Ming} and Hsu, {Jung Fa} and Cheng, {Sheaw Guey} and Lee, {Ching Kuo}",
year = "2008",
month = "12",
day = "15",
doi = "10.1016/j.jchromb.2008.10.042",
language = "English",
volume = "876",
pages = "211--218",
journal = "Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences",
issn = "1570-0232",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Simultaneous detection and quantitation of highly water-soluble herbicides in serum using ion-pair liquid chromatography-tandem mass spectrometry

AU - Wang, Kuang Chuan

AU - Chen, Shih Ming

AU - Hsu, Jung Fa

AU - Cheng, Sheaw Guey

AU - Lee, Ching Kuo

PY - 2008/12/15

Y1 - 2008/12/15

N2 - We report the simultaneous screening of highly polar, water-soluble, and less-volatile herbicides, including glyphosate, glufosinate, paraquat, and diquat, in serum using liquid chromatography-mass spectrometry. The herbicides were separated by solid-phase extraction using a Strata-XC cartridge. A heptafluorobutyric acid solution was chosen as the mobile phase for ion-pair liquid chromatography. Mass spectrometry was used for analysis and was optimized for operation in the positive mode for all analytes. The serum specimens were screened for the presence of the herbicides at the following concentrations: 5 ng/mL for glyphosate, 2 ng/mL for glufosinate, 1 ng/mL for diquat, and 5 ng/mL for paraquat. This is the first report on the simultaneous detection of these compounds.

AB - We report the simultaneous screening of highly polar, water-soluble, and less-volatile herbicides, including glyphosate, glufosinate, paraquat, and diquat, in serum using liquid chromatography-mass spectrometry. The herbicides were separated by solid-phase extraction using a Strata-XC cartridge. A heptafluorobutyric acid solution was chosen as the mobile phase for ion-pair liquid chromatography. Mass spectrometry was used for analysis and was optimized for operation in the positive mode for all analytes. The serum specimens were screened for the presence of the herbicides at the following concentrations: 5 ng/mL for glyphosate, 2 ng/mL for glufosinate, 1 ng/mL for diquat, and 5 ng/mL for paraquat. This is the first report on the simultaneous detection of these compounds.

KW - Glyphosate

KW - Herbicides

KW - HFBA

KW - Ion-pair

KW - LC-MS

KW - Paraquat

UR - http://www.scopus.com/inward/record.url?scp=56749102635&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56749102635&partnerID=8YFLogxK

U2 - 10.1016/j.jchromb.2008.10.042

DO - 10.1016/j.jchromb.2008.10.042

M3 - Article

C2 - 19022710

AN - SCOPUS:56749102635

VL - 876

SP - 211

EP - 218

JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

SN - 1570-0232

IS - 2

ER -