Simultaneous analysis of dextromethorphan and its three metabolites in human plasma using an improved HPLC method with fluorometric detection

Shyr Yi Lin, Chien Ho Chen, Hsiu O. Ho, Hsueh Hui Chen, Ming Thau Sheu

研究成果: 雜誌貢獻文章

27 引文 (Scopus)

摘要

A simple and improved HPLC method with fluorometric detection for simultaneous determination of dextromethorphan (DM) and its three metabolites (dextrorphan (DX), 3-methoxymorphinan (MM), 3-hydroxymorphinan (HM)) in human plasma was developed and validated. The method involved a simple and efficient extraction protocol using an n-heptane/ethyl acetate (1:1) solvent mixture that achieved recoveries of 70-90% with an insignificant interference from the plasma matrix. The analysis was performed on a phenyl column with isocratic elution, a mobile phase composed of 20% methanol, 30% acetonitrile, and 50% KH2PO4 buffer (10 mM, with adding 0.02% of TEA; adjusted with phosphoric acid to pH 3.5), and a run time of only 15 min. Linear calibration curves were constructed in the concentration range of 1-200 nM for DM and its three metabolites. The lower limit of quantitation (LLOQ) in human plasma was 1 nM for each compound. The coefficient of variation and RSE% of the intraday and interday analyses for DM and its three metabolites all complied with USFDA requirements. This analytical method was preliminarily applied to determine the polymorphic functions of CYP2D6 and CYP3A4 in the metabolic pathway of DM to DX and then to HM.
原文英語
頁(從 - 到)141-146
頁數6
期刊Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
859
發行號1
DOIs
出版狀態已發佈 - 十一月 1 2007

指紋

Dextromethorphan
Plasma (human)
Metabolites
Dextrorphan
High Pressure Liquid Chromatography
Cytochrome P-450 CYP3A
Cytochrome P-450 CYP2D6
United States Food and Drug Administration
Metabolic Networks and Pathways
Calibration
Methanol
Buffers
Plasmas
Recovery
norlevorphanol

ASJC Scopus subject areas

  • Biochemistry

引用此文

@article{827885cf55a24b7a90c57bb41343c7d2,
title = "Simultaneous analysis of dextromethorphan and its three metabolites in human plasma using an improved HPLC method with fluorometric detection",
abstract = "A simple and improved HPLC method with fluorometric detection for simultaneous determination of dextromethorphan (DM) and its three metabolites (dextrorphan (DX), 3-methoxymorphinan (MM), 3-hydroxymorphinan (HM)) in human plasma was developed and validated. The method involved a simple and efficient extraction protocol using an n-heptane/ethyl acetate (1:1) solvent mixture that achieved recoveries of 70-90{\%} with an insignificant interference from the plasma matrix. The analysis was performed on a phenyl column with isocratic elution, a mobile phase composed of 20{\%} methanol, 30{\%} acetonitrile, and 50{\%} KH2PO4 buffer (10 mM, with adding 0.02{\%} of TEA; adjusted with phosphoric acid to pH 3.5), and a run time of only 15 min. Linear calibration curves were constructed in the concentration range of 1-200 nM for DM and its three metabolites. The lower limit of quantitation (LLOQ) in human plasma was 1 nM for each compound. The coefficient of variation and RSE{\%} of the intraday and interday analyses for DM and its three metabolites all complied with USFDA requirements. This analytical method was preliminarily applied to determine the polymorphic functions of CYP2D6 and CYP3A4 in the metabolic pathway of DM to DX and then to HM.",
keywords = "Dextromethorphan, Dextrorphan, Hydroxymorphinan, Methoxymorphinan, Phenyl column",
author = "Lin, {Shyr Yi} and Chen, {Chien Ho} and Ho, {Hsiu O.} and Chen, {Hsueh Hui} and Sheu, {Ming Thau}",
year = "2007",
month = "11",
day = "1",
doi = "10.1016/j.jchromb.2007.09.017",
language = "English",
volume = "859",
pages = "141--146",
journal = "Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences",
issn = "1570-0232",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Simultaneous analysis of dextromethorphan and its three metabolites in human plasma using an improved HPLC method with fluorometric detection

AU - Lin, Shyr Yi

AU - Chen, Chien Ho

AU - Ho, Hsiu O.

AU - Chen, Hsueh Hui

AU - Sheu, Ming Thau

PY - 2007/11/1

Y1 - 2007/11/1

N2 - A simple and improved HPLC method with fluorometric detection for simultaneous determination of dextromethorphan (DM) and its three metabolites (dextrorphan (DX), 3-methoxymorphinan (MM), 3-hydroxymorphinan (HM)) in human plasma was developed and validated. The method involved a simple and efficient extraction protocol using an n-heptane/ethyl acetate (1:1) solvent mixture that achieved recoveries of 70-90% with an insignificant interference from the plasma matrix. The analysis was performed on a phenyl column with isocratic elution, a mobile phase composed of 20% methanol, 30% acetonitrile, and 50% KH2PO4 buffer (10 mM, with adding 0.02% of TEA; adjusted with phosphoric acid to pH 3.5), and a run time of only 15 min. Linear calibration curves were constructed in the concentration range of 1-200 nM for DM and its three metabolites. The lower limit of quantitation (LLOQ) in human plasma was 1 nM for each compound. The coefficient of variation and RSE% of the intraday and interday analyses for DM and its three metabolites all complied with USFDA requirements. This analytical method was preliminarily applied to determine the polymorphic functions of CYP2D6 and CYP3A4 in the metabolic pathway of DM to DX and then to HM.

AB - A simple and improved HPLC method with fluorometric detection for simultaneous determination of dextromethorphan (DM) and its three metabolites (dextrorphan (DX), 3-methoxymorphinan (MM), 3-hydroxymorphinan (HM)) in human plasma was developed and validated. The method involved a simple and efficient extraction protocol using an n-heptane/ethyl acetate (1:1) solvent mixture that achieved recoveries of 70-90% with an insignificant interference from the plasma matrix. The analysis was performed on a phenyl column with isocratic elution, a mobile phase composed of 20% methanol, 30% acetonitrile, and 50% KH2PO4 buffer (10 mM, with adding 0.02% of TEA; adjusted with phosphoric acid to pH 3.5), and a run time of only 15 min. Linear calibration curves were constructed in the concentration range of 1-200 nM for DM and its three metabolites. The lower limit of quantitation (LLOQ) in human plasma was 1 nM for each compound. The coefficient of variation and RSE% of the intraday and interday analyses for DM and its three metabolites all complied with USFDA requirements. This analytical method was preliminarily applied to determine the polymorphic functions of CYP2D6 and CYP3A4 in the metabolic pathway of DM to DX and then to HM.

KW - Dextromethorphan

KW - Dextrorphan

KW - Hydroxymorphinan

KW - Methoxymorphinan

KW - Phenyl column

UR - http://www.scopus.com/inward/record.url?scp=35448953005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=35448953005&partnerID=8YFLogxK

U2 - 10.1016/j.jchromb.2007.09.017

DO - 10.1016/j.jchromb.2007.09.017

M3 - Article

C2 - 17919999

AN - SCOPUS:35448953005

VL - 859

SP - 141

EP - 146

JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

SN - 1570-0232

IS - 1

ER -