Simple daily technique to calculate total and interim changes of daily O2 consumption and CO2 production in premature infants.

T. F. Yeh, M. Admani, S. T. Leu, M. Tan, R. S. Pildes

研究成果: 雜誌貢獻文章

13 引文 (Scopus)

摘要

A simple method to calculate oxygen consumption (VO2) and CO2 production (VCO2) over a 24-h period is described. VO2 and VCO2 were measured using flow-through technique and the total VO2 and VCO2 over a given period of time were determined from the area under the O2 and CO2 concentration-time curve of the mixed expired gas. The system was tested in vitro by burning 100% ethyl alcohol. The average error between measured and theoretical values for VO2 was 4.9% and for VCO2 was 4.7%. With a flow rate greater than 5340 ml/min through the system, the correlation coefficient between theoretical VO2 or VCO2 and measured VO2 or VCO2 was 0.99. The method was tested in vivo in 5 premature infants who were nursed under neutral thermal environment and received routine medical care. The results indicate that this simple method can be used to study the total and interim changes of daily VO2 and VCO2 in infants during their ongoing nursery care.

原文英語
頁(從 - 到)534-538
頁數5
期刊Critical Care Medicine
10
發行號8
DOIs
出版狀態已發佈 - 一月 1 1982

指紋

Premature Infants
Nurseries
Oxygen Consumption
Ethanol
Hot Temperature
Gases

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

引用此文

Simple daily technique to calculate total and interim changes of daily O2 consumption and CO2 production in premature infants. / Yeh, T. F.; Admani, M.; Leu, S. T.; Tan, M.; Pildes, R. S.

於: Critical Care Medicine, 卷 10, 編號 8, 01.01.1982, p. 534-538.

研究成果: 雜誌貢獻文章

@article{6de473e562a9437b936af34fe54ca243,
title = "Simple daily technique to calculate total and interim changes of daily O2 consumption and CO2 production in premature infants.",
abstract = "A simple method to calculate oxygen consumption (VO2) and CO2 production (VCO2) over a 24-h period is described. VO2 and VCO2 were measured using flow-through technique and the total VO2 and VCO2 over a given period of time were determined from the area under the O2 and CO2 concentration-time curve of the mixed expired gas. The system was tested in vitro by burning 100{\%} ethyl alcohol. The average error between measured and theoretical values for VO2 was 4.9{\%} and for VCO2 was 4.7{\%}. With a flow rate greater than 5340 ml/min through the system, the correlation coefficient between theoretical VO2 or VCO2 and measured VO2 or VCO2 was 0.99. The method was tested in vivo in 5 premature infants who were nursed under neutral thermal environment and received routine medical care. The results indicate that this simple method can be used to study the total and interim changes of daily VO2 and VCO2 in infants during their ongoing nursery care.",
author = "Yeh, {T. F.} and M. Admani and Leu, {S. T.} and M. Tan and Pildes, {R. S.}",
year = "1982",
month = "1",
day = "1",
doi = "10.1097/00003246-198208000-00011",
language = "English",
volume = "10",
pages = "534--538",
journal = "Critical Care Medicine",
issn = "0090-3493",
publisher = "Lippincott Williams and Wilkins",
number = "8",

}

TY - JOUR

T1 - Simple daily technique to calculate total and interim changes of daily O2 consumption and CO2 production in premature infants.

AU - Yeh, T. F.

AU - Admani, M.

AU - Leu, S. T.

AU - Tan, M.

AU - Pildes, R. S.

PY - 1982/1/1

Y1 - 1982/1/1

N2 - A simple method to calculate oxygen consumption (VO2) and CO2 production (VCO2) over a 24-h period is described. VO2 and VCO2 were measured using flow-through technique and the total VO2 and VCO2 over a given period of time were determined from the area under the O2 and CO2 concentration-time curve of the mixed expired gas. The system was tested in vitro by burning 100% ethyl alcohol. The average error between measured and theoretical values for VO2 was 4.9% and for VCO2 was 4.7%. With a flow rate greater than 5340 ml/min through the system, the correlation coefficient between theoretical VO2 or VCO2 and measured VO2 or VCO2 was 0.99. The method was tested in vivo in 5 premature infants who were nursed under neutral thermal environment and received routine medical care. The results indicate that this simple method can be used to study the total and interim changes of daily VO2 and VCO2 in infants during their ongoing nursery care.

AB - A simple method to calculate oxygen consumption (VO2) and CO2 production (VCO2) over a 24-h period is described. VO2 and VCO2 were measured using flow-through technique and the total VO2 and VCO2 over a given period of time were determined from the area under the O2 and CO2 concentration-time curve of the mixed expired gas. The system was tested in vitro by burning 100% ethyl alcohol. The average error between measured and theoretical values for VO2 was 4.9% and for VCO2 was 4.7%. With a flow rate greater than 5340 ml/min through the system, the correlation coefficient between theoretical VO2 or VCO2 and measured VO2 or VCO2 was 0.99. The method was tested in vivo in 5 premature infants who were nursed under neutral thermal environment and received routine medical care. The results indicate that this simple method can be used to study the total and interim changes of daily VO2 and VCO2 in infants during their ongoing nursery care.

UR - http://www.scopus.com/inward/record.url?scp=0020169488&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020169488&partnerID=8YFLogxK

U2 - 10.1097/00003246-198208000-00011

DO - 10.1097/00003246-198208000-00011

M3 - Article

C2 - 6807603

AN - SCOPUS:0020169488

VL - 10

SP - 534

EP - 538

JO - Critical Care Medicine

JF - Critical Care Medicine

SN - 0090-3493

IS - 8

ER -