摘要
Lodox/Statscan is a new digital radiograph machine with low-dose radiation exposure. It provides rapid and whole-body scans. In multiple gunshot trauma, the conventional radiograph or computed tomography scan might be time consuming, and the resuscitation might be paused temporarily. We applied the Lodox/Statscan to search bullets within a short period, and the resuscitation was nonstop during imaging study. As a result, it serves as a valuable adjunct in providing rapid identification of metal projectiles in multiple gunshot wounds.
原文 | 英語 |
---|---|
期刊 | American Journal of Emergency Medicine |
卷 | 26 |
發行號 | 8 |
DOIs | |
出版狀態 | 已發佈 - 十月 2008 |
對外發佈 | Yes |
指紋
ASJC Scopus subject areas
- Emergency Medicine
引用此文
Lodox/Statscan provides rapid identification of bullets in multiple gunshot wounds. / Fu, Chih Yuan; Wu, Shih Chi; Chen, Ray Jade.
於: American Journal of Emergency Medicine, 卷 26, 編號 8, 10.2008.研究成果: 雜誌貢獻 › 文章
}
TY - JOUR
T1 - Lodox/Statscan provides rapid identification of bullets in multiple gunshot wounds
AU - Fu, Chih Yuan
AU - Wu, Shih Chi
AU - Chen, Ray Jade
PY - 2008/10
Y1 - 2008/10
N2 - Lodox/Statscan is a new digital radiograph machine with low-dose radiation exposure. It provides rapid and whole-body scans. In multiple gunshot trauma, the conventional radiograph or computed tomography scan might be time consuming, and the resuscitation might be paused temporarily. We applied the Lodox/Statscan to search bullets within a short period, and the resuscitation was nonstop during imaging study. As a result, it serves as a valuable adjunct in providing rapid identification of metal projectiles in multiple gunshot wounds.
AB - Lodox/Statscan is a new digital radiograph machine with low-dose radiation exposure. It provides rapid and whole-body scans. In multiple gunshot trauma, the conventional radiograph or computed tomography scan might be time consuming, and the resuscitation might be paused temporarily. We applied the Lodox/Statscan to search bullets within a short period, and the resuscitation was nonstop during imaging study. As a result, it serves as a valuable adjunct in providing rapid identification of metal projectiles in multiple gunshot wounds.
UR - http://www.scopus.com/inward/record.url?scp=52949085536&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=52949085536&partnerID=8YFLogxK
U2 - 10.1016/j.ajem.2008.01.047
DO - 10.1016/j.ajem.2008.01.047
M3 - Article
C2 - 18926367
AN - SCOPUS:52949085536
VL - 26
JO - American Journal of Emergency Medicine
JF - American Journal of Emergency Medicine
SN - 0735-6757
IS - 8
ER -