Large array elements decoding system for ultrasound images

Jian Chiun Liou, Wen Chieh Lin

研究成果: 書貢獻/報告類型會議貢獻

摘要

This new method eliminates the possibility of false triggering in the traditional signal due to mutual cross between the ultrasonic systems. Such as: The second reflection, ultrasonic probe with the angle of the angle shift and other issues. It is the main principle for the probe geometry position after the dislocation. Each element of the probe received a drive signal does not affect the probe in the adjacent two elements and open the wrong move. While the corresponding odd number of probes generated by the image A, and the corresponding number of probes generated by the image B. The two images overlap and present a complete and high resolution ultrasound image. It can control more than 2000 probe elements.
原文英語
主出版物標題Proceedings of the 2017 IEEE International Conference on Applied System Innovation
主出版物子標題Applied System Innovation for Modern Technology, ICASI 2017
發行者Institute of Electrical and Electronics Engineers Inc.
頁面1898-1899
頁數2
ISBN(電子)9781509048977
DOIs
出版狀態已發佈 - 七月 21 2017
對外發佈Yes
事件2017 IEEE International Conference on Applied System Innovation, ICASI 2017 - Sapporo, 日本
持續時間: 五月 13 2017五月 17 2017

會議

會議2017 IEEE International Conference on Applied System Innovation, ICASI 2017
國家日本
城市Sapporo
期間5/13/175/17/17

指紋

decoding
Ultrasonics
Decoding
probes
Ultrasonic reflection
ultrasonics
Geometry
shift
high resolution
geometry

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Computer Science Applications
  • Hardware and Architecture
  • Safety, Risk, Reliability and Quality
  • Mechanical Engineering
  • Media Technology
  • Health Informatics
  • Instrumentation

引用此文

Liou, J. C., & Lin, W. C. (2017). Large array elements decoding system for ultrasound images. 於 Proceedings of the 2017 IEEE International Conference on Applied System Innovation: Applied System Innovation for Modern Technology, ICASI 2017 (頁 1898-1899). [7988320] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICASI.2017.7988320

Large array elements decoding system for ultrasound images. / Liou, Jian Chiun; Lin, Wen Chieh.

Proceedings of the 2017 IEEE International Conference on Applied System Innovation: Applied System Innovation for Modern Technology, ICASI 2017. Institute of Electrical and Electronics Engineers Inc., 2017. p. 1898-1899 7988320.

研究成果: 書貢獻/報告類型會議貢獻

Liou, JC & Lin, WC 2017, Large array elements decoding system for ultrasound images. 於 Proceedings of the 2017 IEEE International Conference on Applied System Innovation: Applied System Innovation for Modern Technology, ICASI 2017., 7988320, Institute of Electrical and Electronics Engineers Inc., 頁 1898-1899, 2017 IEEE International Conference on Applied System Innovation, ICASI 2017, Sapporo, 日本, 5/13/17. https://doi.org/10.1109/ICASI.2017.7988320
Liou JC, Lin WC. Large array elements decoding system for ultrasound images. 於 Proceedings of the 2017 IEEE International Conference on Applied System Innovation: Applied System Innovation for Modern Technology, ICASI 2017. Institute of Electrical and Electronics Engineers Inc. 2017. p. 1898-1899. 7988320 https://doi.org/10.1109/ICASI.2017.7988320
Liou, Jian Chiun ; Lin, Wen Chieh. / Large array elements decoding system for ultrasound images. Proceedings of the 2017 IEEE International Conference on Applied System Innovation: Applied System Innovation for Modern Technology, ICASI 2017. Institute of Electrical and Electronics Engineers Inc., 2017. 頁 1898-1899
@inproceedings{b042b4ce3a5248e0852af908ec7a6355,
title = "Large array elements decoding system for ultrasound images",
abstract = "This new method eliminates the possibility of false triggering in the traditional signal due to mutual cross between the ultrasonic systems. Such as: The second reflection, ultrasonic probe with the angle of the angle shift and other issues. It is the main principle for the probe geometry position after the dislocation. Each element of the probe received a drive signal does not affect the probe in the adjacent two elements and open the wrong move. While the corresponding odd number of probes generated by the image A, and the corresponding number of probes generated by the image B. The two images overlap and present a complete and high resolution ultrasound image. It can control more than 2000 probe elements.",
keywords = "Noise interference, Probe, Ultrasound image",
author = "Liou, {Jian Chiun} and Lin, {Wen Chieh}",
year = "2017",
month = "7",
day = "21",
doi = "10.1109/ICASI.2017.7988320",
language = "English",
pages = "1898--1899",
booktitle = "Proceedings of the 2017 IEEE International Conference on Applied System Innovation",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Large array elements decoding system for ultrasound images

AU - Liou, Jian Chiun

AU - Lin, Wen Chieh

PY - 2017/7/21

Y1 - 2017/7/21

N2 - This new method eliminates the possibility of false triggering in the traditional signal due to mutual cross between the ultrasonic systems. Such as: The second reflection, ultrasonic probe with the angle of the angle shift and other issues. It is the main principle for the probe geometry position after the dislocation. Each element of the probe received a drive signal does not affect the probe in the adjacent two elements and open the wrong move. While the corresponding odd number of probes generated by the image A, and the corresponding number of probes generated by the image B. The two images overlap and present a complete and high resolution ultrasound image. It can control more than 2000 probe elements.

AB - This new method eliminates the possibility of false triggering in the traditional signal due to mutual cross between the ultrasonic systems. Such as: The second reflection, ultrasonic probe with the angle of the angle shift and other issues. It is the main principle for the probe geometry position after the dislocation. Each element of the probe received a drive signal does not affect the probe in the adjacent two elements and open the wrong move. While the corresponding odd number of probes generated by the image A, and the corresponding number of probes generated by the image B. The two images overlap and present a complete and high resolution ultrasound image. It can control more than 2000 probe elements.

KW - Noise interference

KW - Probe

KW - Ultrasound image

UR - http://www.scopus.com/inward/record.url?scp=85028534698&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028534698&partnerID=8YFLogxK

U2 - 10.1109/ICASI.2017.7988320

DO - 10.1109/ICASI.2017.7988320

M3 - Conference contribution

AN - SCOPUS:85028534698

SP - 1898

EP - 1899

BT - Proceedings of the 2017 IEEE International Conference on Applied System Innovation

PB - Institute of Electrical and Electronics Engineers Inc.

ER -