In vitro and intraoperative laxities after single-bundle and double-bundle anterior cruciate ligament reconstructions

Hemanth R. Gadikota, Jong Keun Seon, Chih Hui Chen, Jia Lin Wu, Thomas J. Gill, Guoan Li

研究成果: 雜誌貢獻文章

20 引文 斯高帕斯(Scopus)

摘要

Purpose: The purpose of this study was to objectively evaluate whether double-bundle anterior cruciate ligament (ACL) reconstruction can better restore the normal translational and rotational laxities than the conventional single-bundle ACL reconstruction among the reported biomechanical studies. Methods: A systematic literature search was conducted to identify in vitro and in vivo (intraoperative) biomechanical studies that compared the laxities (anterior or anteroposterior or rotational) between single- and double-bundle ACL reconstructions. Because of large variability among the loading conditions and testing methods used to determine the rotational laxities among the studies, a meta-analysis of rotational laxities was not feasible. Results: Seven in vitro and three in vivo studies were included in this analysis based on the predefined inclusion criteria. The overall mean differences calculated by the random effects model in anteroposterior laxity between the single-bundle and double-bundle ACL reconstruction techniques at 0°, 30°, 60°, and 90° of flexion were 0.99 mm, 0.38 mm, 0.34 mm, and 0.07 mm, respectively. No statistically significant difference was noted between the 2 treatments at all flexion angles. Among the 9 studies that compared the rotational laxity of single-bundle and double-bundle ACL reconstructions, 4 reported that double-bundle reconstruction can provide better rotational control than single-bundle reconstruction. The other 5 studies could not identify any significant difference between the 2 reconstructions in terms of rotational laxity. Conclusions: Both single- and double-bundle treatment options for ACL injury result in similar anteroposterior knee joint laxity at time 0. No conclusive evidence on the superiority of 1 reconstruction technique over the other in terms of rotation laxity can be obtained because of several variations in the experimental protocol and the kinematics used to measure the rotational laxity among the studies. Level of Evidence: Level III, meta-analysis.

原文英語
頁(從 - 到)849-860
頁數12
期刊Arthroscopy - Journal of Arthroscopic and Related Surgery
27
發行號6
DOIs
出版狀態已發佈 - 六月 2011
對外發佈Yes

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

指紋 深入研究「In vitro and intraoperative laxities after single-bundle and double-bundle anterior cruciate ligament reconstructions」主題。共同形成了獨特的指紋。

  • 引用此