High throughput and parallel flow cytometer with solid immersion microball lens array

Y. J. Fan, Horn Jiunn Sheen, Pei Yu Chiou

研究成果: 書貢獻/報告類型會議貢獻

1 引文 (Scopus)

摘要

We demonstrate a high-throughput fluorescence based microfluidic flow cytometer with 64 microfluidic channels with each channel capable of detecting 1600 droplets/sec. This cytometer is realized by utilizing solid immersed high N.A. microball lens array for high sensitivity, parallel, and low chromatic aberration detection across a 6 mm distance.
原文英語
主出版物標題2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012
頁面1041-1044
頁數4
DOIs
出版狀態已發佈 - 2012
對外發佈Yes
事件2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012 - Paris, 法国
持續時間: 一月 29 2012二月 2 2012

會議

會議2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012
國家法国
城市Paris
期間1/29/122/2/12

指紋

parallel flow
Parallel flow
Microfluidics
submerging
Lenses
lenses
Throughput
Aberrations
aberration
Fluorescence
fluorescence
sensitivity

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Condensed Matter Physics
  • Electronic, Optical and Magnetic Materials

引用此文

Fan, Y. J., Sheen, H. J., & Chiou, P. Y. (2012). High throughput and parallel flow cytometer with solid immersion microball lens array. 於 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012 (頁 1041-1044). [6170249] https://doi.org/10.1109/MEMSYS.2012.6170249

High throughput and parallel flow cytometer with solid immersion microball lens array. / Fan, Y. J.; Sheen, Horn Jiunn; Chiou, Pei Yu.

2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012. 2012. p. 1041-1044 6170249.

研究成果: 書貢獻/報告類型會議貢獻

Fan, YJ, Sheen, HJ & Chiou, PY 2012, High throughput and parallel flow cytometer with solid immersion microball lens array. 於 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012., 6170249, 頁 1041-1044, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012, Paris, 法国, 1/29/12. https://doi.org/10.1109/MEMSYS.2012.6170249
Fan YJ, Sheen HJ, Chiou PY. High throughput and parallel flow cytometer with solid immersion microball lens array. 於 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012. 2012. p. 1041-1044. 6170249 https://doi.org/10.1109/MEMSYS.2012.6170249
Fan, Y. J. ; Sheen, Horn Jiunn ; Chiou, Pei Yu. / High throughput and parallel flow cytometer with solid immersion microball lens array. 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012. 2012. 頁 1041-1044
@inproceedings{fea0d9a84c4e4cd8a8d16cdd006490e9,
title = "High throughput and parallel flow cytometer with solid immersion microball lens array",
abstract = "We demonstrate a high-throughput fluorescence based microfluidic flow cytometer with 64 microfluidic channels with each channel capable of detecting 1600 droplets/sec. This cytometer is realized by utilizing solid immersed high N.A. microball lens array for high sensitivity, parallel, and low chromatic aberration detection across a 6 mm distance.",
author = "Fan, {Y. J.} and Sheen, {Horn Jiunn} and Chiou, {Pei Yu}",
year = "2012",
doi = "10.1109/MEMSYS.2012.6170249",
language = "English",
isbn = "9781467303248",
pages = "1041--1044",
booktitle = "2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012",

}

TY - GEN

T1 - High throughput and parallel flow cytometer with solid immersion microball lens array

AU - Fan, Y. J.

AU - Sheen, Horn Jiunn

AU - Chiou, Pei Yu

PY - 2012

Y1 - 2012

N2 - We demonstrate a high-throughput fluorescence based microfluidic flow cytometer with 64 microfluidic channels with each channel capable of detecting 1600 droplets/sec. This cytometer is realized by utilizing solid immersed high N.A. microball lens array for high sensitivity, parallel, and low chromatic aberration detection across a 6 mm distance.

AB - We demonstrate a high-throughput fluorescence based microfluidic flow cytometer with 64 microfluidic channels with each channel capable of detecting 1600 droplets/sec. This cytometer is realized by utilizing solid immersed high N.A. microball lens array for high sensitivity, parallel, and low chromatic aberration detection across a 6 mm distance.

UR - http://www.scopus.com/inward/record.url?scp=84860491491&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860491491&partnerID=8YFLogxK

U2 - 10.1109/MEMSYS.2012.6170249

DO - 10.1109/MEMSYS.2012.6170249

M3 - Conference contribution

AN - SCOPUS:84860491491

SN - 9781467303248

SP - 1041

EP - 1044

BT - 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems, MEMS 2012

ER -