TY - JOUR
T1 - Hemocompatibility evaluation of plasma-nitrided austenitic stainless steels at low temperature
AU - Lin, Yun Ho
AU - Lan, Wen Chien
AU - Ou, Keng Liang
AU - Liu, Cheng Ming
AU - Peng, Pei Wen
PY - 2012/7/15
Y1 - 2012/7/15
N2 - In this study, plasma-nitrided austenitic stainless steel was prepared using a microwave system as a function of the nitriding duration. The nitride layers were characterized via scanning electron microscopy, transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy, atomic force microscopy and a Vickers micro-hardness tester. The effects of plasma nitriding on the compatibility of blood with the austenitic stainless steel were also investigated. Based on the XRD and TEM observations, it was inferred that only a single γ N phase was detected in the whole process of experiments. The γ N layer, which was formed on austenitic stainless steel, exhibited lower platelet adhesion and activation than the untreated specimens. The clotting time of the PN specimens was prolonged and increased with the treatment time. This work suggested that the blood-compatible manner of plasma nitriding by controlling surface characteristic on austenitic stainless steel improved the anticoagulant properties, and made austenitic stainless steel suitable candidates in the field of surgical and medical instruments.
AB - In this study, plasma-nitrided austenitic stainless steel was prepared using a microwave system as a function of the nitriding duration. The nitride layers were characterized via scanning electron microscopy, transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy, atomic force microscopy and a Vickers micro-hardness tester. The effects of plasma nitriding on the compatibility of blood with the austenitic stainless steel were also investigated. Based on the XRD and TEM observations, it was inferred that only a single γ N phase was detected in the whole process of experiments. The γ N layer, which was formed on austenitic stainless steel, exhibited lower platelet adhesion and activation than the untreated specimens. The clotting time of the PN specimens was prolonged and increased with the treatment time. This work suggested that the blood-compatible manner of plasma nitriding by controlling surface characteristic on austenitic stainless steel improved the anticoagulant properties, and made austenitic stainless steel suitable candidates in the field of surgical and medical instruments.
KW - γ phase
KW - 303 austenitic stainless steel
KW - Plasma nitriding
UR - http://www.scopus.com/inward/record.url?scp=84863779355&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863779355&partnerID=8YFLogxK
U2 - 10.1016/j.surfcoat.2012.03.089
DO - 10.1016/j.surfcoat.2012.03.089
M3 - Article
AN - SCOPUS:84863779355
SN - 0257-8972
VL - 206
SP - 4785
EP - 4790
JO - Surface and Coatings Technology
JF - Surface and Coatings Technology
IS - 23
ER -