Gait analysis by using tri-axial accelerometer of smart phones

Guan Sheng Huang, Chao Cheng Wu, Jiannher Lin

研究成果: 書貢獻/報告類型會議貢獻

1 引文 (Scopus)

摘要

Gait has been one of important indicators for healthcare. Traditional methods were often confined in the laboratory and record actions of experimenters by using sophisticated instruments [1]. In 2005, the personal digital assistants (PDAs) is used to measurement and analysis by Mantyjarvi, J. et al.[2]. This manuscript further extends this idea by turning smart phones into gait measurement devices and took advantage of the embedded tri-axial accelerometer as measurement instrument. Three popular signal techniques included the Fourier Transform (FT), Short Time Fourier Transform (STFT), and Hilbert-Huang Transform (HHT) would be deployed to analyze the collected data. The experimental study indicated that HHT provide significant results for gait analysis and further demonstrated the utilities of the proposed methods, which made use of low end smart phone as the gait measurement tool.
原文英語
主出版物標題ICCH 2012 Proceedings - International Conference on Computerized Healthcare
發行者IEEE Computer Society
頁面29-34
頁數6
ISBN(列印)9781467351294
DOIs
出版狀態已發佈 - 一月 1 2012
事件2012 International Conference on Computerized Healthcare, ICCH 2012 - Hong Kong, 中国
持續時間: 十二月 17 2012十二月 18 2012

會議

會議2012 International Conference on Computerized Healthcare, ICCH 2012
國家中国
城市Hong Kong
期間12/17/1212/18/12

指紋

Gait
Fourier Analysis
Handheld Computers
Delivery of Health Care
Equipment and Supplies
Smartphone

ASJC Scopus subject areas

  • Health Informatics

引用此文

Huang, G. S., Wu, C. C., & Lin, J. (2012). Gait analysis by using tri-axial accelerometer of smart phones. 於 ICCH 2012 Proceedings - International Conference on Computerized Healthcare (頁 29-34). [6724466] IEEE Computer Society. https://doi.org/10.1109/ICCH.2012.6724466

Gait analysis by using tri-axial accelerometer of smart phones. / Huang, Guan Sheng; Wu, Chao Cheng; Lin, Jiannher.

ICCH 2012 Proceedings - International Conference on Computerized Healthcare. IEEE Computer Society, 2012. p. 29-34 6724466.

研究成果: 書貢獻/報告類型會議貢獻

Huang, GS, Wu, CC & Lin, J 2012, Gait analysis by using tri-axial accelerometer of smart phones. 於 ICCH 2012 Proceedings - International Conference on Computerized Healthcare., 6724466, IEEE Computer Society, 頁 29-34, 2012 International Conference on Computerized Healthcare, ICCH 2012, Hong Kong, 中国, 12/17/12. https://doi.org/10.1109/ICCH.2012.6724466
Huang GS, Wu CC, Lin J. Gait analysis by using tri-axial accelerometer of smart phones. 於 ICCH 2012 Proceedings - International Conference on Computerized Healthcare. IEEE Computer Society. 2012. p. 29-34. 6724466 https://doi.org/10.1109/ICCH.2012.6724466
Huang, Guan Sheng ; Wu, Chao Cheng ; Lin, Jiannher. / Gait analysis by using tri-axial accelerometer of smart phones. ICCH 2012 Proceedings - International Conference on Computerized Healthcare. IEEE Computer Society, 2012. 頁 29-34
@inproceedings{4031ccd2383848d181275738b413dc33,
title = "Gait analysis by using tri-axial accelerometer of smart phones",
abstract = "Gait has been one of important indicators for healthcare. Traditional methods were often confined in the laboratory and record actions of experimenters by using sophisticated instruments [1]. In 2005, the personal digital assistants (PDAs) is used to measurement and analysis by Mantyjarvi, J. et al.[2]. This manuscript further extends this idea by turning smart phones into gait measurement devices and took advantage of the embedded tri-axial accelerometer as measurement instrument. Three popular signal techniques included the Fourier Transform (FT), Short Time Fourier Transform (STFT), and Hilbert-Huang Transform (HHT) would be deployed to analyze the collected data. The experimental study indicated that HHT provide significant results for gait analysis and further demonstrated the utilities of the proposed methods, which made use of low end smart phone as the gait measurement tool.",
keywords = "Fourier transform (FT), Gait analysis, Hilbert-Hunag Transform (HHT), Short time Fourier Transform (STFT), smart phone, Tri-axial accelerometer",
author = "Huang, {Guan Sheng} and Wu, {Chao Cheng} and Jiannher Lin",
year = "2012",
month = "1",
day = "1",
doi = "10.1109/ICCH.2012.6724466",
language = "English",
isbn = "9781467351294",
pages = "29--34",
booktitle = "ICCH 2012 Proceedings - International Conference on Computerized Healthcare",
publisher = "IEEE Computer Society",
address = "United States",

}

TY - GEN

T1 - Gait analysis by using tri-axial accelerometer of smart phones

AU - Huang, Guan Sheng

AU - Wu, Chao Cheng

AU - Lin, Jiannher

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Gait has been one of important indicators for healthcare. Traditional methods were often confined in the laboratory and record actions of experimenters by using sophisticated instruments [1]. In 2005, the personal digital assistants (PDAs) is used to measurement and analysis by Mantyjarvi, J. et al.[2]. This manuscript further extends this idea by turning smart phones into gait measurement devices and took advantage of the embedded tri-axial accelerometer as measurement instrument. Three popular signal techniques included the Fourier Transform (FT), Short Time Fourier Transform (STFT), and Hilbert-Huang Transform (HHT) would be deployed to analyze the collected data. The experimental study indicated that HHT provide significant results for gait analysis and further demonstrated the utilities of the proposed methods, which made use of low end smart phone as the gait measurement tool.

AB - Gait has been one of important indicators for healthcare. Traditional methods were often confined in the laboratory and record actions of experimenters by using sophisticated instruments [1]. In 2005, the personal digital assistants (PDAs) is used to measurement and analysis by Mantyjarvi, J. et al.[2]. This manuscript further extends this idea by turning smart phones into gait measurement devices and took advantage of the embedded tri-axial accelerometer as measurement instrument. Three popular signal techniques included the Fourier Transform (FT), Short Time Fourier Transform (STFT), and Hilbert-Huang Transform (HHT) would be deployed to analyze the collected data. The experimental study indicated that HHT provide significant results for gait analysis and further demonstrated the utilities of the proposed methods, which made use of low end smart phone as the gait measurement tool.

KW - Fourier transform (FT)

KW - Gait analysis

KW - Hilbert-Hunag Transform (HHT)

KW - Short time Fourier Transform (STFT)

KW - smart phone

KW - Tri-axial accelerometer

UR - http://www.scopus.com/inward/record.url?scp=84894192320&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84894192320&partnerID=8YFLogxK

U2 - 10.1109/ICCH.2012.6724466

DO - 10.1109/ICCH.2012.6724466

M3 - Conference contribution

SN - 9781467351294

SP - 29

EP - 34

BT - ICCH 2012 Proceedings - International Conference on Computerized Healthcare

PB - IEEE Computer Society

ER -