Estimation of the effective lens position using a rotating Scheimpflug camera

Jau Der Ho, Shiow Wen Liou, Jui-Fang Tsai, Ching Yao Tsai

研究成果: 雜誌貢獻文章

11 引文 (Scopus)

摘要

Purpose: To describe a no-history method of estimating the effective lens position (ELP) for double-K intraocular lens (IOL) power calculation in eyes that had previous refractive surgery. Setting: Departments of Ophthalmology, Taipei Medical University Hospital and Taipei City Hospital, Taipei, Taiwan. Methods: The corneal height (H m) and anterior chamber diameter (AG m) in 106 unoperated eyes were measured using a rotating Scheimpflug camera. The theoretical anterior corneal radius (R rt) was then derived from H m and AG m by regression and rearrangement of the Fyodorov equation. The ELP estimate was then calculated from R rt. The performance of this ELP estimation method in double-K IOL power calculation and the performance of other methods were compared retrospectively in 11 eyes having cataract surgery that had previous refractive surgery. The refractive results 9 to 12 weeks after cataract surgery were selected for data analysis. Results: The new ELP estimation method, combined with the BESSt formula or the Savini et al. method for estimating post refractive-surgery corneal power (K post) in the double-K SRK/T formula, provided the best IOL power prediction results. The mean arithmetic and absolute IOL prediction errors were -0.05 ± 0.62 diopters (D) and 0.49 ± 0.34 D, respectively, when combined with the BESSt formula and 0.03 ± 0.73 D and 0.60 ± 0.36 D, respectively, when combined with the Savini et al. method. With either combination, all 11 eyes were within ±1.00 D of the refractive prediction error. Conclusion: This ELP estimation method may be helpful for IOL power calculation in post refractive-surgery eyes when historical data are unavailable.
原文英語
頁(從 - 到)2119-2127
頁數9
期刊Journal of Cataract and Refractive Surgery
34
發行號12
DOIs
出版狀態已發佈 - 十二月 2008

指紋

Lenses
Intraocular Lenses
Refractive Surgical Procedures
Cataract
Refractive Errors
Urban Hospitals
Anterior Chamber
Ophthalmology
Taiwan
History

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Surgery

引用此文

Estimation of the effective lens position using a rotating Scheimpflug camera. / Ho, Jau Der; Liou, Shiow Wen; Tsai, Jui-Fang; Tsai, Ching Yao.

於: Journal of Cataract and Refractive Surgery, 卷 34, 編號 12, 12.2008, p. 2119-2127.

研究成果: 雜誌貢獻文章

Ho, Jau Der ; Liou, Shiow Wen ; Tsai, Jui-Fang ; Tsai, Ching Yao. / Estimation of the effective lens position using a rotating Scheimpflug camera. 於: Journal of Cataract and Refractive Surgery. 2008 ; 卷 34, 編號 12. 頁 2119-2127.
@article{b6b1c385bff14bc2bf525ef432923973,
title = "Estimation of the effective lens position using a rotating Scheimpflug camera",
abstract = "Purpose: To describe a no-history method of estimating the effective lens position (ELP) for double-K intraocular lens (IOL) power calculation in eyes that had previous refractive surgery. Setting: Departments of Ophthalmology, Taipei Medical University Hospital and Taipei City Hospital, Taipei, Taiwan. Methods: The corneal height (H m) and anterior chamber diameter (AG m) in 106 unoperated eyes were measured using a rotating Scheimpflug camera. The theoretical anterior corneal radius (R rt) was then derived from H m and AG m by regression and rearrangement of the Fyodorov equation. The ELP estimate was then calculated from R rt. The performance of this ELP estimation method in double-K IOL power calculation and the performance of other methods were compared retrospectively in 11 eyes having cataract surgery that had previous refractive surgery. The refractive results 9 to 12 weeks after cataract surgery were selected for data analysis. Results: The new ELP estimation method, combined with the BESSt formula or the Savini et al. method for estimating post refractive-surgery corneal power (K post) in the double-K SRK/T formula, provided the best IOL power prediction results. The mean arithmetic and absolute IOL prediction errors were -0.05 ± 0.62 diopters (D) and 0.49 ± 0.34 D, respectively, when combined with the BESSt formula and 0.03 ± 0.73 D and 0.60 ± 0.36 D, respectively, when combined with the Savini et al. method. With either combination, all 11 eyes were within ±1.00 D of the refractive prediction error. Conclusion: This ELP estimation method may be helpful for IOL power calculation in post refractive-surgery eyes when historical data are unavailable.",
author = "Ho, {Jau Der} and Liou, {Shiow Wen} and Jui-Fang Tsai and Tsai, {Ching Yao}",
year = "2008",
month = "12",
doi = "10.1016/j.jcrs.2008.08.030",
language = "English",
volume = "34",
pages = "2119--2127",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "12",

}

TY - JOUR

T1 - Estimation of the effective lens position using a rotating Scheimpflug camera

AU - Ho, Jau Der

AU - Liou, Shiow Wen

AU - Tsai, Jui-Fang

AU - Tsai, Ching Yao

PY - 2008/12

Y1 - 2008/12

N2 - Purpose: To describe a no-history method of estimating the effective lens position (ELP) for double-K intraocular lens (IOL) power calculation in eyes that had previous refractive surgery. Setting: Departments of Ophthalmology, Taipei Medical University Hospital and Taipei City Hospital, Taipei, Taiwan. Methods: The corneal height (H m) and anterior chamber diameter (AG m) in 106 unoperated eyes were measured using a rotating Scheimpflug camera. The theoretical anterior corneal radius (R rt) was then derived from H m and AG m by regression and rearrangement of the Fyodorov equation. The ELP estimate was then calculated from R rt. The performance of this ELP estimation method in double-K IOL power calculation and the performance of other methods were compared retrospectively in 11 eyes having cataract surgery that had previous refractive surgery. The refractive results 9 to 12 weeks after cataract surgery were selected for data analysis. Results: The new ELP estimation method, combined with the BESSt formula or the Savini et al. method for estimating post refractive-surgery corneal power (K post) in the double-K SRK/T formula, provided the best IOL power prediction results. The mean arithmetic and absolute IOL prediction errors were -0.05 ± 0.62 diopters (D) and 0.49 ± 0.34 D, respectively, when combined with the BESSt formula and 0.03 ± 0.73 D and 0.60 ± 0.36 D, respectively, when combined with the Savini et al. method. With either combination, all 11 eyes were within ±1.00 D of the refractive prediction error. Conclusion: This ELP estimation method may be helpful for IOL power calculation in post refractive-surgery eyes when historical data are unavailable.

AB - Purpose: To describe a no-history method of estimating the effective lens position (ELP) for double-K intraocular lens (IOL) power calculation in eyes that had previous refractive surgery. Setting: Departments of Ophthalmology, Taipei Medical University Hospital and Taipei City Hospital, Taipei, Taiwan. Methods: The corneal height (H m) and anterior chamber diameter (AG m) in 106 unoperated eyes were measured using a rotating Scheimpflug camera. The theoretical anterior corneal radius (R rt) was then derived from H m and AG m by regression and rearrangement of the Fyodorov equation. The ELP estimate was then calculated from R rt. The performance of this ELP estimation method in double-K IOL power calculation and the performance of other methods were compared retrospectively in 11 eyes having cataract surgery that had previous refractive surgery. The refractive results 9 to 12 weeks after cataract surgery were selected for data analysis. Results: The new ELP estimation method, combined with the BESSt formula or the Savini et al. method for estimating post refractive-surgery corneal power (K post) in the double-K SRK/T formula, provided the best IOL power prediction results. The mean arithmetic and absolute IOL prediction errors were -0.05 ± 0.62 diopters (D) and 0.49 ± 0.34 D, respectively, when combined with the BESSt formula and 0.03 ± 0.73 D and 0.60 ± 0.36 D, respectively, when combined with the Savini et al. method. With either combination, all 11 eyes were within ±1.00 D of the refractive prediction error. Conclusion: This ELP estimation method may be helpful for IOL power calculation in post refractive-surgery eyes when historical data are unavailable.

UR - http://www.scopus.com/inward/record.url?scp=56549111981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56549111981&partnerID=8YFLogxK

U2 - 10.1016/j.jcrs.2008.08.030

DO - 10.1016/j.jcrs.2008.08.030

M3 - Article

C2 - 19027570

AN - SCOPUS:56549111981

VL - 34

SP - 2119

EP - 2127

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 12

ER -