Development of a high-performance liquid chromatographic method for bioanalytical applications with sulpiride

M. C. Huang, H. O. Ho, G. C. Yeh, W. T. Ke, L. C. Lin, T. M. Bruce Hsu, C. C. Kao, M. T. Sheu

研究成果: 雜誌貢獻文章同行評審

34 引文 斯高帕斯(Scopus)

摘要

An improved HPLC method using a silica gel column with fluorescence detection (excitation at 300 nm and emission at 365 nm) was developed for the determination of sulpiride concentrations in plasma. Analysis of sulpiride in plasma samples was simplified by a one-step liquid-liquid extraction after alkaline treatment of only 1 ml of plasma. The low limit of quantitation was 20 ng/ml with a coefficient of variation of less than 20%. A linear range was found from 20 to 1500 ng/ml. This HPLC method was validated with the precision for inter-day and intra-day runs being 0.36-8.01% and 0.29-5.25%, respectively, and the accuracy (standard deviation of mean, SD) for inter-day and intra-day runs being -1.58 to 5.02% and -2.14 to 5.21%, respectively. Bioequivalence of the two products was evaluated in 12 normal healthy male volunteers in a single-dose, two-period, two-sequence, two-treatment cross-over study. Sulpiride plasma concentrations were analyzed with this validated HPLC method. Results demonstrated that the two tablet formulations of sulpiride appear to be bioequivalent.

原文英語
頁(從 - 到)157-163
頁數7
期刊Journal of Chromatography B: Biomedical Sciences and Applications
763
發行號1-2
DOIs
出版狀態已發佈 - 十一月 5 2001

ASJC Scopus subject areas

  • Chemistry(all)

指紋 深入研究「Development of a high-performance liquid chromatographic method for bioanalytical applications with sulpiride」主題。共同形成了獨特的指紋。

引用此