Deformability of mice erythrocytes measured by oscillatory optical tweezers

Yu Shan Huang, Chia Lun Yeh, Guan Bo Liao, Yi Fan Chen, Ting Fen Tsai, Arthur Chiou

研究成果: 書貢獻/報告類型會議貢獻

1 引文 (Scopus)

摘要

We used one-dimensional oscillatory optical tweezers in a discrete scanning (or jumping) mode to trap and stretch individual mice erythrocytes and measured their deformation as a function of the jumping distance of the oscillatory trapping beam. In general, we observed that the length of the long axis of red blood cells (RBCs) decreased slightly at small jumping distance and then increased after the jumping distance exceeded a threshold value on the order of a few microns, which is consistent with a recent theoretical prediction. The deformability of three types of mice RBCs, namely the wide-type mice (serving as the control group), old mice, and gene knockout mice were measured and compared. Statistical analysis of their deformability reveals that the RBCs of old mice can be distinguished from those of knockout mice even though these two types of mice exhibit many similar aging-like features.
原文英語
主出版物標題Proceedings of SPIE - The International Society for Optical Engineering
7038
DOIs
出版狀態已發佈 - 2008
對外發佈Yes
事件Optical Trapping and Optical Micromanipulation V - San Diego, CA, 美国
持續時間: 八月 10 2008八月 13 2008

其他

其他Optical Trapping and Optical Micromanipulation V
國家美国
城市San Diego, CA
期間8/10/088/13/08

指紋

Optical tweezers
Optical Tweezers
Erythrocyte
erythrocytes
Formability
mice
Mouse
Blood
knockout mice
Cells
Red Blood Cells
Statistical methods
Genes
Aging of materials
Scanning
genes
statistical analysis
Stretch
Threshold Value
Trapping

ASJC Scopus subject areas

  • Applied Mathematics
  • Computer Science Applications
  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics

引用此文

Huang, Y. S., Yeh, C. L., Liao, G. B., Chen, Y. F., Tsai, T. F., & Chiou, A. (2008). Deformability of mice erythrocytes measured by oscillatory optical tweezers. 於 Proceedings of SPIE - The International Society for Optical Engineering (卷 7038). [703809] https://doi.org/10.1117/12.794690

Deformability of mice erythrocytes measured by oscillatory optical tweezers. / Huang, Yu Shan; Yeh, Chia Lun; Liao, Guan Bo; Chen, Yi Fan; Tsai, Ting Fen; Chiou, Arthur.

Proceedings of SPIE - The International Society for Optical Engineering. 卷 7038 2008. 703809.

研究成果: 書貢獻/報告類型會議貢獻

Huang, YS, Yeh, CL, Liao, GB, Chen, YF, Tsai, TF & Chiou, A 2008, Deformability of mice erythrocytes measured by oscillatory optical tweezers. 於 Proceedings of SPIE - The International Society for Optical Engineering. 卷 7038, 703809, Optical Trapping and Optical Micromanipulation V, San Diego, CA, 美国, 8/10/08. https://doi.org/10.1117/12.794690
Huang YS, Yeh CL, Liao GB, Chen YF, Tsai TF, Chiou A. Deformability of mice erythrocytes measured by oscillatory optical tweezers. 於 Proceedings of SPIE - The International Society for Optical Engineering. 卷 7038. 2008. 703809 https://doi.org/10.1117/12.794690
Huang, Yu Shan ; Yeh, Chia Lun ; Liao, Guan Bo ; Chen, Yi Fan ; Tsai, Ting Fen ; Chiou, Arthur. / Deformability of mice erythrocytes measured by oscillatory optical tweezers. Proceedings of SPIE - The International Society for Optical Engineering. 卷 7038 2008.
@inproceedings{863689915c684b09bad195d49ba12f74,
title = "Deformability of mice erythrocytes measured by oscillatory optical tweezers",
abstract = "We used one-dimensional oscillatory optical tweezers in a discrete scanning (or jumping) mode to trap and stretch individual mice erythrocytes and measured their deformation as a function of the jumping distance of the oscillatory trapping beam. In general, we observed that the length of the long axis of red blood cells (RBCs) decreased slightly at small jumping distance and then increased after the jumping distance exceeded a threshold value on the order of a few microns, which is consistent with a recent theoretical prediction. The deformability of three types of mice RBCs, namely the wide-type mice (serving as the control group), old mice, and gene knockout mice were measured and compared. Statistical analysis of their deformability reveals that the RBCs of old mice can be distinguished from those of knockout mice even though these two types of mice exhibit many similar aging-like features.",
keywords = "Erythrocyte, Gene knockout, Oscillatory optical tweezers",
author = "Huang, {Yu Shan} and Yeh, {Chia Lun} and Liao, {Guan Bo} and Chen, {Yi Fan} and Tsai, {Ting Fen} and Arthur Chiou",
year = "2008",
doi = "10.1117/12.794690",
language = "English",
isbn = "9780819472588",
volume = "7038",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",

}

TY - GEN

T1 - Deformability of mice erythrocytes measured by oscillatory optical tweezers

AU - Huang, Yu Shan

AU - Yeh, Chia Lun

AU - Liao, Guan Bo

AU - Chen, Yi Fan

AU - Tsai, Ting Fen

AU - Chiou, Arthur

PY - 2008

Y1 - 2008

N2 - We used one-dimensional oscillatory optical tweezers in a discrete scanning (or jumping) mode to trap and stretch individual mice erythrocytes and measured their deformation as a function of the jumping distance of the oscillatory trapping beam. In general, we observed that the length of the long axis of red blood cells (RBCs) decreased slightly at small jumping distance and then increased after the jumping distance exceeded a threshold value on the order of a few microns, which is consistent with a recent theoretical prediction. The deformability of three types of mice RBCs, namely the wide-type mice (serving as the control group), old mice, and gene knockout mice were measured and compared. Statistical analysis of their deformability reveals that the RBCs of old mice can be distinguished from those of knockout mice even though these two types of mice exhibit many similar aging-like features.

AB - We used one-dimensional oscillatory optical tweezers in a discrete scanning (or jumping) mode to trap and stretch individual mice erythrocytes and measured their deformation as a function of the jumping distance of the oscillatory trapping beam. In general, we observed that the length of the long axis of red blood cells (RBCs) decreased slightly at small jumping distance and then increased after the jumping distance exceeded a threshold value on the order of a few microns, which is consistent with a recent theoretical prediction. The deformability of three types of mice RBCs, namely the wide-type mice (serving as the control group), old mice, and gene knockout mice were measured and compared. Statistical analysis of their deformability reveals that the RBCs of old mice can be distinguished from those of knockout mice even though these two types of mice exhibit many similar aging-like features.

KW - Erythrocyte

KW - Gene knockout

KW - Oscillatory optical tweezers

UR - http://www.scopus.com/inward/record.url?scp=56249085274&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56249085274&partnerID=8YFLogxK

U2 - 10.1117/12.794690

DO - 10.1117/12.794690

M3 - Conference contribution

AN - SCOPUS:56249085274

SN - 9780819472588

VL - 7038

BT - Proceedings of SPIE - The International Society for Optical Engineering

ER -