Corrigendum

Advances of techniques in deep regional blocks (BioMed Research International (2017) 2017 (4) DOI: 10.1155/2017/7268308)

Jui An Lin, Rafael Blanco, Yasuyuki Shibata, Tatsuo Nakamoto, Ko Huan Lin

研究成果: 雜誌貢獻評論/辯論

摘要

In the article titled "Advances of Techniques in Deep Regional Blocks" [1], Table 1 was missing. Accordingly, the table is shown below, and its in-text citation is added as follows: Our preliminary qualitative analysis demonstrated that, by using the pressure management system of Injectomat Agilia® pump (Fresenius Vial, Brezins, France) as an inline manometer between the needle (the tip inserted 3 cm into the pork model) and the low-dead space extension tube, pushing pressure generated by the act of half-the-air was below 15 psi during injection (experiment was run in triplicate, and occlusion alarm did not occur after the flow had commenced in response to half-the-air pressure exerted in the 20mL local anesthetic syringe with the syringe pump set to an infusion rate of 0.1ml/h and a pressure limit of 750mmHg) (Table 1). Table presented.
原文英語
文章編號5151645
期刊BioMed Research International
2018
DOIs
出版狀態已發佈 - 一月 1 2018

指紋

Syringes
Pressure
Research
Air Pressure
Pumps
Manometers
Local Anesthetics
France
Needles
Air
Injections
4-iodo-2,5-dimethoxyphenylisopropylamine
corrigendum
Experiments
Red Meat

ASJC Scopus subject areas

  • Biochemistry, Genetics and Molecular Biology(all)
  • Immunology and Microbiology(all)

引用此文

Corrigendum : Advances of techniques in deep regional blocks (BioMed Research International (2017) 2017 (4) DOI: 10.1155/2017/7268308). / Lin, Jui An; Blanco, Rafael; Shibata, Yasuyuki; Nakamoto, Tatsuo; Lin, Ko Huan.

於: BioMed Research International, 卷 2018, 5151645, 01.01.2018.

研究成果: 雜誌貢獻評論/辯論

@article{e6a371856df940c5bc58cfecd9f85116,
title = "Corrigendum: Advances of techniques in deep regional blocks (BioMed Research International (2017) 2017 (4) DOI: 10.1155/2017/7268308)",
abstract = "In the article titled {"}Advances of Techniques in Deep Regional Blocks{"} [1], Table 1 was missing. Accordingly, the table is shown below, and its in-text citation is added as follows: Our preliminary qualitative analysis demonstrated that, by using the pressure management system of Injectomat Agilia{\circledR} pump (Fresenius Vial, Brezins, France) as an inline manometer between the needle (the tip inserted 3 cm into the pork model) and the low-dead space extension tube, pushing pressure generated by the act of half-the-air was below 15 psi during injection (experiment was run in triplicate, and occlusion alarm did not occur after the flow had commenced in response to half-the-air pressure exerted in the 20mL local anesthetic syringe with the syringe pump set to an infusion rate of 0.1ml/h and a pressure limit of 750mmHg) (Table 1). Table presented.",
author = "Lin, {Jui An} and Rafael Blanco and Yasuyuki Shibata and Tatsuo Nakamoto and Lin, {Ko Huan}",
year = "2018",
month = "1",
day = "1",
doi = "10.1155/2018/5151645",
language = "English",
volume = "2018",
journal = "BioMed Research International",
issn = "2314-6133",
publisher = "Hindawi Publishing Corporation",

}

TY - JOUR

T1 - Corrigendum

T2 - Advances of techniques in deep regional blocks (BioMed Research International (2017) 2017 (4) DOI: 10.1155/2017/7268308)

AU - Lin, Jui An

AU - Blanco, Rafael

AU - Shibata, Yasuyuki

AU - Nakamoto, Tatsuo

AU - Lin, Ko Huan

PY - 2018/1/1

Y1 - 2018/1/1

N2 - In the article titled "Advances of Techniques in Deep Regional Blocks" [1], Table 1 was missing. Accordingly, the table is shown below, and its in-text citation is added as follows: Our preliminary qualitative analysis demonstrated that, by using the pressure management system of Injectomat Agilia® pump (Fresenius Vial, Brezins, France) as an inline manometer between the needle (the tip inserted 3 cm into the pork model) and the low-dead space extension tube, pushing pressure generated by the act of half-the-air was below 15 psi during injection (experiment was run in triplicate, and occlusion alarm did not occur after the flow had commenced in response to half-the-air pressure exerted in the 20mL local anesthetic syringe with the syringe pump set to an infusion rate of 0.1ml/h and a pressure limit of 750mmHg) (Table 1). Table presented.

AB - In the article titled "Advances of Techniques in Deep Regional Blocks" [1], Table 1 was missing. Accordingly, the table is shown below, and its in-text citation is added as follows: Our preliminary qualitative analysis demonstrated that, by using the pressure management system of Injectomat Agilia® pump (Fresenius Vial, Brezins, France) as an inline manometer between the needle (the tip inserted 3 cm into the pork model) and the low-dead space extension tube, pushing pressure generated by the act of half-the-air was below 15 psi during injection (experiment was run in triplicate, and occlusion alarm did not occur after the flow had commenced in response to half-the-air pressure exerted in the 20mL local anesthetic syringe with the syringe pump set to an infusion rate of 0.1ml/h and a pressure limit of 750mmHg) (Table 1). Table presented.

UR - http://www.scopus.com/inward/record.url?scp=85050243255&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85050243255&partnerID=8YFLogxK

U2 - 10.1155/2018/5151645

DO - 10.1155/2018/5151645

M3 - Comment/debate

VL - 2018

JO - BioMed Research International

JF - BioMed Research International

SN - 2314-6133

M1 - 5151645

ER -