Cervical carcinoma: MR imaging with integrated endorectal/phased-array coils: A pilot study

L. J. Wang, Y. C. Wong, C. J. Chen, K. G. Huang, S. Hsueh

研究成果: 雜誌貢獻文章

5 引文 (Scopus)

摘要

The purpose of this study was to investigate the value of using MRI with integrated endorectal/phased-array coils for the staging and determination of the extent of cervical carcinoma. Twenty-two consecutive patients with biopsy-proven cervical carcinoma underwent MRI with integrated endorectal/phased-array coils before treatment. Magnetic resonance imaging was compared with clinical staging using surgical and pathological results as the gold standard. Eighteen of 22 patients underwent surgery. Seventeen of the 18 patients were correctly staged using an integrated endorectal/phased-array MRI with an overall staging accuracy of 94%. Fourteen of the 18 patients had a correct clinical staging with an overall staging accuracy of 78%. The overall accuracy of pelvic lymph node metastasis detection was 89% on MRI. These data showed that MRI using integrated endorectal/phased-array coils was more accurate than the clinical approach for the staging of cervical carcinoma. Magnetic resonance imaging using integrated endorectal/phased-array coils is a highly promising modality for detecting and staging cervical carcinomas.

原文英語
頁(從 - 到)1822-1827
頁數6
期刊European Radiology
11
發行號9
DOIs
出版狀態已發佈 - 2001
對外發佈Yes

指紋

Carcinoma
Magnetic Resonance Imaging
Lymph Nodes
Neoplasm Metastasis
Biopsy
Therapeutics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

引用此文

Cervical carcinoma : MR imaging with integrated endorectal/phased-array coils: A pilot study. / Wang, L. J.; Wong, Y. C.; Chen, C. J.; Huang, K. G.; Hsueh, S.

於: European Radiology, 卷 11, 編號 9, 2001, p. 1822-1827.

研究成果: 雜誌貢獻文章

Wang, L. J. ; Wong, Y. C. ; Chen, C. J. ; Huang, K. G. ; Hsueh, S. / Cervical carcinoma : MR imaging with integrated endorectal/phased-array coils: A pilot study. 於: European Radiology. 2001 ; 卷 11, 編號 9. 頁 1822-1827.
@article{f350f88148a448cb956a62c0eeda0ab4,
title = "Cervical carcinoma: MR imaging with integrated endorectal/phased-array coils: A pilot study",
abstract = "The purpose of this study was to investigate the value of using MRI with integrated endorectal/phased-array coils for the staging and determination of the extent of cervical carcinoma. Twenty-two consecutive patients with biopsy-proven cervical carcinoma underwent MRI with integrated endorectal/phased-array coils before treatment. Magnetic resonance imaging was compared with clinical staging using surgical and pathological results as the gold standard. Eighteen of 22 patients underwent surgery. Seventeen of the 18 patients were correctly staged using an integrated endorectal/phased-array MRI with an overall staging accuracy of 94{\%}. Fourteen of the 18 patients had a correct clinical staging with an overall staging accuracy of 78{\%}. The overall accuracy of pelvic lymph node metastasis detection was 89{\%} on MRI. These data showed that MRI using integrated endorectal/phased-array coils was more accurate than the clinical approach for the staging of cervical carcinoma. Magnetic resonance imaging using integrated endorectal/phased-array coils is a highly promising modality for detecting and staging cervical carcinomas.",
keywords = "Clinical FIGO staging, Integrated endorectal/phased-array coils, MR imaging, Uterine cervical carcinoma",
author = "Wang, {L. J.} and Wong, {Y. C.} and Chen, {C. J.} and Huang, {K. G.} and S. Hsueh",
year = "2001",
doi = "10.1007/s003300000794",
language = "English",
volume = "11",
pages = "1822--1827",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer Verlag",
number = "9",

}

TY - JOUR

T1 - Cervical carcinoma

T2 - MR imaging with integrated endorectal/phased-array coils: A pilot study

AU - Wang, L. J.

AU - Wong, Y. C.

AU - Chen, C. J.

AU - Huang, K. G.

AU - Hsueh, S.

PY - 2001

Y1 - 2001

N2 - The purpose of this study was to investigate the value of using MRI with integrated endorectal/phased-array coils for the staging and determination of the extent of cervical carcinoma. Twenty-two consecutive patients with biopsy-proven cervical carcinoma underwent MRI with integrated endorectal/phased-array coils before treatment. Magnetic resonance imaging was compared with clinical staging using surgical and pathological results as the gold standard. Eighteen of 22 patients underwent surgery. Seventeen of the 18 patients were correctly staged using an integrated endorectal/phased-array MRI with an overall staging accuracy of 94%. Fourteen of the 18 patients had a correct clinical staging with an overall staging accuracy of 78%. The overall accuracy of pelvic lymph node metastasis detection was 89% on MRI. These data showed that MRI using integrated endorectal/phased-array coils was more accurate than the clinical approach for the staging of cervical carcinoma. Magnetic resonance imaging using integrated endorectal/phased-array coils is a highly promising modality for detecting and staging cervical carcinomas.

AB - The purpose of this study was to investigate the value of using MRI with integrated endorectal/phased-array coils for the staging and determination of the extent of cervical carcinoma. Twenty-two consecutive patients with biopsy-proven cervical carcinoma underwent MRI with integrated endorectal/phased-array coils before treatment. Magnetic resonance imaging was compared with clinical staging using surgical and pathological results as the gold standard. Eighteen of 22 patients underwent surgery. Seventeen of the 18 patients were correctly staged using an integrated endorectal/phased-array MRI with an overall staging accuracy of 94%. Fourteen of the 18 patients had a correct clinical staging with an overall staging accuracy of 78%. The overall accuracy of pelvic lymph node metastasis detection was 89% on MRI. These data showed that MRI using integrated endorectal/phased-array coils was more accurate than the clinical approach for the staging of cervical carcinoma. Magnetic resonance imaging using integrated endorectal/phased-array coils is a highly promising modality for detecting and staging cervical carcinomas.

KW - Clinical FIGO staging

KW - Integrated endorectal/phased-array coils

KW - MR imaging

KW - Uterine cervical carcinoma

UR - http://www.scopus.com/inward/record.url?scp=0034850857&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034850857&partnerID=8YFLogxK

U2 - 10.1007/s003300000794

DO - 10.1007/s003300000794

M3 - Article

C2 - 11511908

AN - SCOPUS:0034850857

VL - 11

SP - 1822

EP - 1827

JO - European Radiology

JF - European Radiology

SN - 0938-7994

IS - 9

ER -