Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests

Chian Her Lee, Ching Chi Hsu, Po Yuang Huang

研究成果: 雜誌貢獻文章

9 引文 (Scopus)

摘要

The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries.

原文英語
頁(從 - 到)250-257
頁數8
期刊Computers in Biology and Medicine
87
DOIs
出版狀態已發佈 - 八月 1 2017

指紋

Sacroiliac Joint
Finite Element Analysis
Biomechanics
Pelvis
Bone
Musculoskeletal system
Ligaments
Wounds and Injuries
Muscle
Mechanics
Compaction
Finite element method
Engineers
Therapeutics
Biomechanical Phenomena
Femur
Spine
Musculoskeletal System
Fracture Fixation
Bone Fractures

ASJC Scopus subject areas

  • Computer Science Applications
  • Health Informatics

引用此文

@article{22cf62ad87e6464584d34afc42775712,
title = "Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests",
abstract = "The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries.",
keywords = "Biomechanical tests, Finite element analyses, Fixation stability, Implant failure, Sacroiliac joint injury",
author = "Lee, {Chian Her} and Hsu, {Ching Chi} and Huang, {Po Yuang}",
year = "2017",
month = "8",
day = "1",
doi = "10.1016/j.compbiomed.2017.06.007",
language = "English",
volume = "87",
pages = "250--257",
journal = "Computers in Biology and Medicine",
issn = "0010-4825",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests

AU - Lee, Chian Her

AU - Hsu, Ching Chi

AU - Huang, Po Yuang

PY - 2017/8/1

Y1 - 2017/8/1

N2 - The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries.

AB - The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries.

KW - Biomechanical tests

KW - Finite element analyses

KW - Fixation stability

KW - Implant failure

KW - Sacroiliac joint injury

UR - http://www.scopus.com/inward/record.url?scp=85020378813&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85020378813&partnerID=8YFLogxK

U2 - 10.1016/j.compbiomed.2017.06.007

DO - 10.1016/j.compbiomed.2017.06.007

M3 - Article

AN - SCOPUS:85020378813

VL - 87

SP - 250

EP - 257

JO - Computers in Biology and Medicine

JF - Computers in Biology and Medicine

SN - 0010-4825

ER -