Background and Aims: Radiologists can learn from referring clinicians’ feedback to improve quality
and accuracy of radiology reports. The present report aims to understand revised radiology reports of
a medical center in Taiwan, and compare the results in 2011-2012 (Period-1) vs. 2013-2014 (Period-2).
Methods: A total of 318 revised reports in Period-1 (vs. 235, Period-2) were analyzed and divided into
five types: initial misdiagnosis, transcription errors, requested by clinicians, obtained additional
information, and defective films. All initial radiology reports were included and trainees reports were
excluded in this audit.
Results: The rate of revised reports was 0.05% in Period-1 (vs. 0.03%, Period-2). Of these, plain Xrays had 64 films (vs. 34, Period-2), CT had 105 films (vs. 100, Period-2), MRI had 98 films (vs. 70,
Period-2), and other special procedure examinations had 51 films (vs. 31, Period-2). The most frequent
reason for revision of plain X-rays reports was initial misdiagnosis 48.4% (vs. 50%, Period-2). Initial
misdiagnosis was the main reason for revision of CT reports in Period-1 (35.2%) and requested by
clinicians was the main reason for revision of CT reports in Period-2 (42%). Requested by clinicians was
the main reason for revision of MRI reports 31.6% (vs. 30%, Period-2). Requested by clinicians was the
main reason for revision of special procedure examinations in Period-1 (25.5%) and transcription errors
was the main reason in Period-2 (32.3%).
Conclusion: The rates of revised reports were slightly decreased in two audited periods. The diagnostic
discrepancies were various among different imaging modalities. This audit has allowed and stimulated
the medical team for fully awareness of the interpretation and reporting process, thereby improving the
quality of our work.
原文英語
出版狀態已發佈 - 十一月 2015
事件Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 - Taipei, 臺灣
持續時間: 十一月 14 2014十一月 15 2014
http://www.nrst.tw/news/news_info.asp?id=553

會議

會議Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015
縮寫名稱APQS 2015
國家臺灣
城市Taipei
期間11/14/1411/15/14
網際網路位址

指紋

Taiwan
Radiology
Diagnostic Errors
X-Rays

引用此文

Chang, P-Y., Chen, C-Y., Yao, M. S., Huang, C-J., & Chan, W. P. (2015). An audit of revised radiology reports of a medical center in Taiwan. 論文發表於 Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 , Taipei, 臺灣.

An audit of revised radiology reports of a medical center in Taiwan. / Chang, Po-Yen; Chen, Chia-Yuen; Yao, Min Szu; Huang, Chien-Ju; Chan, Wing P.

2015. 論文發表於 Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 , Taipei, 臺灣.

研究成果: 會議貢獻類型論文

Chang, P-Y, Chen, C-Y, Yao, MS, Huang, C-J & Chan, WP 2015, 'An audit of revised radiology reports of a medical center in Taiwan' 論文發表於 Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 , Taipei, 臺灣, 11/14/14 - 11/15/14, .
Chang P-Y, Chen C-Y, Yao MS, Huang C-J, Chan WP. An audit of revised radiology reports of a medical center in Taiwan. 2015. 論文發表於 Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 , Taipei, 臺灣.
Chang, Po-Yen ; Chen, Chia-Yuen ; Yao, Min Szu ; Huang, Chien-Ju ; Chan, Wing P. / An audit of revised radiology reports of a medical center in Taiwan. 論文發表於 Asia-Pacific Forum on Quality and Safety of Medical Imaging 2015 , Taipei, 臺灣.
@conference{75d300c6375042bca497dafeba63287d,
title = "An audit of revised radiology reports of a medical center in Taiwan",
abstract = "Background and Aims: Radiologists can learn from referring clinicians’ feedback to improve qualityand accuracy of radiology reports. The present report aims to understand revised radiology reports ofa medical center in Taiwan, and compare the results in 2011-2012 (Period-1) vs. 2013-2014 (Period-2).Methods: A total of 318 revised reports in Period-1 (vs. 235, Period-2) were analyzed and divided intofive types: initial misdiagnosis, transcription errors, requested by clinicians, obtained additionalinformation, and defective films. All initial radiology reports were included and trainees reports wereexcluded in this audit.Results: The rate of revised reports was 0.05{\%} in Period-1 (vs. 0.03{\%}, Period-2). Of these, plain Xrays had 64 films (vs. 34, Period-2), CT had 105 films (vs. 100, Period-2), MRI had 98 films (vs. 70,Period-2), and other special procedure examinations had 51 films (vs. 31, Period-2). The most frequentreason for revision of plain X-rays reports was initial misdiagnosis 48.4{\%} (vs. 50{\%}, Period-2). Initialmisdiagnosis was the main reason for revision of CT reports in Period-1 (35.2{\%}) and requested byclinicians was the main reason for revision of CT reports in Period-2 (42{\%}). Requested by clinicians wasthe main reason for revision of MRI reports 31.6{\%} (vs. 30{\%}, Period-2). Requested by clinicians was themain reason for revision of special procedure examinations in Period-1 (25.5{\%}) and transcription errorswas the main reason in Period-2 (32.3{\%}).Conclusion: The rates of revised reports were slightly decreased in two audited periods. The diagnosticdiscrepancies were various among different imaging modalities. This audit has allowed and stimulatedthe medical team for fully awareness of the interpretation and reporting process, thereby improving thequality of our work.",
author = "Po-Yen Chang and Chia-Yuen Chen and Yao, {Min Szu} and Chien-Ju Huang and Chan, {Wing P.}",
year = "2015",
month = "11",
language = "English",
note = "null ; Conference date: 14-11-2014 Through 15-11-2014",
url = "http://www.nrst.tw/news/news_info.asp?id=553",

}

TY - CONF

T1 - An audit of revised radiology reports of a medical center in Taiwan

AU - Chang, Po-Yen

AU - Chen, Chia-Yuen

AU - Yao, Min Szu

AU - Huang, Chien-Ju

AU - Chan, Wing P.

PY - 2015/11

Y1 - 2015/11

N2 - Background and Aims: Radiologists can learn from referring clinicians’ feedback to improve qualityand accuracy of radiology reports. The present report aims to understand revised radiology reports ofa medical center in Taiwan, and compare the results in 2011-2012 (Period-1) vs. 2013-2014 (Period-2).Methods: A total of 318 revised reports in Period-1 (vs. 235, Period-2) were analyzed and divided intofive types: initial misdiagnosis, transcription errors, requested by clinicians, obtained additionalinformation, and defective films. All initial radiology reports were included and trainees reports wereexcluded in this audit.Results: The rate of revised reports was 0.05% in Period-1 (vs. 0.03%, Period-2). Of these, plain Xrays had 64 films (vs. 34, Period-2), CT had 105 films (vs. 100, Period-2), MRI had 98 films (vs. 70,Period-2), and other special procedure examinations had 51 films (vs. 31, Period-2). The most frequentreason for revision of plain X-rays reports was initial misdiagnosis 48.4% (vs. 50%, Period-2). Initialmisdiagnosis was the main reason for revision of CT reports in Period-1 (35.2%) and requested byclinicians was the main reason for revision of CT reports in Period-2 (42%). Requested by clinicians wasthe main reason for revision of MRI reports 31.6% (vs. 30%, Period-2). Requested by clinicians was themain reason for revision of special procedure examinations in Period-1 (25.5%) and transcription errorswas the main reason in Period-2 (32.3%).Conclusion: The rates of revised reports were slightly decreased in two audited periods. The diagnosticdiscrepancies were various among different imaging modalities. This audit has allowed and stimulatedthe medical team for fully awareness of the interpretation and reporting process, thereby improving thequality of our work.

AB - Background and Aims: Radiologists can learn from referring clinicians’ feedback to improve qualityand accuracy of radiology reports. The present report aims to understand revised radiology reports ofa medical center in Taiwan, and compare the results in 2011-2012 (Period-1) vs. 2013-2014 (Period-2).Methods: A total of 318 revised reports in Period-1 (vs. 235, Period-2) were analyzed and divided intofive types: initial misdiagnosis, transcription errors, requested by clinicians, obtained additionalinformation, and defective films. All initial radiology reports were included and trainees reports wereexcluded in this audit.Results: The rate of revised reports was 0.05% in Period-1 (vs. 0.03%, Period-2). Of these, plain Xrays had 64 films (vs. 34, Period-2), CT had 105 films (vs. 100, Period-2), MRI had 98 films (vs. 70,Period-2), and other special procedure examinations had 51 films (vs. 31, Period-2). The most frequentreason for revision of plain X-rays reports was initial misdiagnosis 48.4% (vs. 50%, Period-2). Initialmisdiagnosis was the main reason for revision of CT reports in Period-1 (35.2%) and requested byclinicians was the main reason for revision of CT reports in Period-2 (42%). Requested by clinicians wasthe main reason for revision of MRI reports 31.6% (vs. 30%, Period-2). Requested by clinicians was themain reason for revision of special procedure examinations in Period-1 (25.5%) and transcription errorswas the main reason in Period-2 (32.3%).Conclusion: The rates of revised reports were slightly decreased in two audited periods. The diagnosticdiscrepancies were various among different imaging modalities. This audit has allowed and stimulatedthe medical team for fully awareness of the interpretation and reporting process, thereby improving thequality of our work.

M3 - Paper

ER -