An ASIC chip for DNA droplets arrangement and detection system

Wei Jie Wen, Jian Chiun Liou

研究成果: 書貢獻/報告類型會議貢獻

1 引文 (Scopus)

摘要

An ASIC chip of inkjet printer heads system and multi-channel printhead jets using novel encoding algorithm system. Addressing N bits jets elements switch circuit system is using in inkjet chip. Logic functions integrated, enabling TIJ-based products has become increasingly high-end market. Inkjet printers can put small number of DNA droplets (usually only a few picoliters, 10-12 liters) accurately sprayed on to DNA glasses media. Integrated circuit of the TIJ described transducer array to provide the 1024 ejection jets, includes a data interface, an DNA ink-jet treatment, short-pulse generation and bidirectional method operation. The chip system also has an output function to manage of multi-chip electronic components into larger arrays. TIJ spray hole array chip design architecture that allows less than 10 input lines op addressing 1024 nozzles.
原文英語
主出版物標題2016 5th International Symposium on Next-Generation Electronics, ISNE 2016
發行者Institute of Electrical and Electronics Engineers Inc.
ISBN(電子)9781509024391
DOIs
出版狀態已發佈 - 八月 12 2016
對外發佈Yes
事件5th International Symposium on Next-Generation Electronics, ISNE 2016 - Hsinchu, 臺灣
持續時間: 五月 4 2016五月 6 2016

會議

會議5th International Symposium on Next-Generation Electronics, ISNE 2016
國家臺灣
城市Hsinchu
期間5/4/165/6/16

指紋

Application specific integrated circuits
DNA
Ink
Integrated circuits
Transducers
Nozzles
Switches
Glass
Networks (circuits)

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials

引用此文

Wen, W. J., & Liou, J. C. (2016). An ASIC chip for DNA droplets arrangement and detection system. 於 2016 5th International Symposium on Next-Generation Electronics, ISNE 2016 [7543356] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ISNE.2016.7543356

An ASIC chip for DNA droplets arrangement and detection system. / Wen, Wei Jie; Liou, Jian Chiun.

2016 5th International Symposium on Next-Generation Electronics, ISNE 2016. Institute of Electrical and Electronics Engineers Inc., 2016. 7543356.

研究成果: 書貢獻/報告類型會議貢獻

Wen, WJ & Liou, JC 2016, An ASIC chip for DNA droplets arrangement and detection system. 於 2016 5th International Symposium on Next-Generation Electronics, ISNE 2016., 7543356, Institute of Electrical and Electronics Engineers Inc., 5th International Symposium on Next-Generation Electronics, ISNE 2016, Hsinchu, 臺灣, 5/4/16. https://doi.org/10.1109/ISNE.2016.7543356
Wen WJ, Liou JC. An ASIC chip for DNA droplets arrangement and detection system. 於 2016 5th International Symposium on Next-Generation Electronics, ISNE 2016. Institute of Electrical and Electronics Engineers Inc. 2016. 7543356 https://doi.org/10.1109/ISNE.2016.7543356
Wen, Wei Jie ; Liou, Jian Chiun. / An ASIC chip for DNA droplets arrangement and detection system. 2016 5th International Symposium on Next-Generation Electronics, ISNE 2016. Institute of Electrical and Electronics Engineers Inc., 2016.
@inproceedings{e5c4f2d2df0f4a5893645c0d179b8806,
title = "An ASIC chip for DNA droplets arrangement and detection system",
abstract = "An ASIC chip of inkjet printer heads system and multi-channel printhead jets using novel encoding algorithm system. Addressing N bits jets elements switch circuit system is using in inkjet chip. Logic functions integrated, enabling TIJ-based products has become increasingly high-end market. Inkjet printers can put small number of DNA droplets (usually only a few picoliters, 10-12 liters) accurately sprayed on to DNA glasses media. Integrated circuit of the TIJ described transducer array to provide the 1024 ejection jets, includes a data interface, an DNA ink-jet treatment, short-pulse generation and bidirectional method operation. The chip system also has an output function to manage of multi-chip electronic components into larger arrays. TIJ spray hole array chip design architecture that allows less than 10 input lines op addressing 1024 nozzles.",
keywords = "ASIC, DNA, Multiplexer",
author = "Wen, {Wei Jie} and Liou, {Jian Chiun}",
year = "2016",
month = "8",
day = "12",
doi = "10.1109/ISNE.2016.7543356",
language = "English",
booktitle = "2016 5th International Symposium on Next-Generation Electronics, ISNE 2016",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - An ASIC chip for DNA droplets arrangement and detection system

AU - Wen, Wei Jie

AU - Liou, Jian Chiun

PY - 2016/8/12

Y1 - 2016/8/12

N2 - An ASIC chip of inkjet printer heads system and multi-channel printhead jets using novel encoding algorithm system. Addressing N bits jets elements switch circuit system is using in inkjet chip. Logic functions integrated, enabling TIJ-based products has become increasingly high-end market. Inkjet printers can put small number of DNA droplets (usually only a few picoliters, 10-12 liters) accurately sprayed on to DNA glasses media. Integrated circuit of the TIJ described transducer array to provide the 1024 ejection jets, includes a data interface, an DNA ink-jet treatment, short-pulse generation and bidirectional method operation. The chip system also has an output function to manage of multi-chip electronic components into larger arrays. TIJ spray hole array chip design architecture that allows less than 10 input lines op addressing 1024 nozzles.

AB - An ASIC chip of inkjet printer heads system and multi-channel printhead jets using novel encoding algorithm system. Addressing N bits jets elements switch circuit system is using in inkjet chip. Logic functions integrated, enabling TIJ-based products has become increasingly high-end market. Inkjet printers can put small number of DNA droplets (usually only a few picoliters, 10-12 liters) accurately sprayed on to DNA glasses media. Integrated circuit of the TIJ described transducer array to provide the 1024 ejection jets, includes a data interface, an DNA ink-jet treatment, short-pulse generation and bidirectional method operation. The chip system also has an output function to manage of multi-chip electronic components into larger arrays. TIJ spray hole array chip design architecture that allows less than 10 input lines op addressing 1024 nozzles.

KW - ASIC

KW - DNA

KW - Multiplexer

UR - http://www.scopus.com/inward/record.url?scp=84985910580&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84985910580&partnerID=8YFLogxK

U2 - 10.1109/ISNE.2016.7543356

DO - 10.1109/ISNE.2016.7543356

M3 - Conference contribution

AN - SCOPUS:84985910580

BT - 2016 5th International Symposium on Next-Generation Electronics, ISNE 2016

PB - Institute of Electrical and Electronics Engineers Inc.

ER -