A pelvic motion driven electrical stimulator for drop-foot treatment

Shih Wei Chen, Shih Ching Chen, Chiun Fan Chen, Jin Shin Lai, Te Son Kuo

研究成果: 書貢獻/報告類型會議貢獻

5 引文 (Scopus)

摘要

Foot switches operating with force sensitive resistors placed in the shoe sole were considered as an effective way for driving FES assisted walking systems in gait restoration. However, the reliability and durability of the foot switches run down after a certain number of steps. As an alternative for foot switches, a simple, portable, and easy to handle motion driven electrical stimulator (ES) is provided for drop foot treatment. The device is equipped with a single tri-axis accelerometer worn on the pelvis, a commercial dual channel electrical stimulator, and a controller unit. By monitoring the pelvic rotation and acceleration during a walking cycle, the events including heel strike and toe off of each step is thereby predicted by a post-processing neural network model.

原文英語
主出版物標題Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
頁面666-669
頁數4
DOIs
出版狀態已發佈 - 2009
事件31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009 - Minneapolis, MN, 美国
持續時間: 九月 2 2009九月 6 2009

其他

其他31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
國家美国
城市Minneapolis, MN
期間9/2/099/6/09

指紋

Foot
Switches
Walking
Accelerometers
Resistors
Restoration
Neural Networks (Computer)
Shoes
Heel
Toes
Durability
Pelvis
Gait
Neural networks
Controllers
Monitoring
Processing
Equipment and Supplies

ASJC Scopus subject areas

  • Cell Biology
  • Developmental Biology
  • Biomedical Engineering
  • Medicine(all)

引用此文

Chen, S. W., Chen, S. C., Chen, C. F., Lai, J. S., & Kuo, T. S. (2009). A pelvic motion driven electrical stimulator for drop-foot treatment. 於 Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009 (頁 666-669). [5333671] https://doi.org/10.1109/IEMBS.2009.5333671

A pelvic motion driven electrical stimulator for drop-foot treatment. / Chen, Shih Wei; Chen, Shih Ching; Chen, Chiun Fan; Lai, Jin Shin; Kuo, Te Son.

Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009. 2009. p. 666-669 5333671.

研究成果: 書貢獻/報告類型會議貢獻

Chen, SW, Chen, SC, Chen, CF, Lai, JS & Kuo, TS 2009, A pelvic motion driven electrical stimulator for drop-foot treatment. 於 Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009., 5333671, 頁 666-669, 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009, Minneapolis, MN, 美国, 9/2/09. https://doi.org/10.1109/IEMBS.2009.5333671
Chen SW, Chen SC, Chen CF, Lai JS, Kuo TS. A pelvic motion driven electrical stimulator for drop-foot treatment. 於 Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009. 2009. p. 666-669. 5333671 https://doi.org/10.1109/IEMBS.2009.5333671
Chen, Shih Wei ; Chen, Shih Ching ; Chen, Chiun Fan ; Lai, Jin Shin ; Kuo, Te Son. / A pelvic motion driven electrical stimulator for drop-foot treatment. Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009. 2009. 頁 666-669
@inproceedings{4267a4094d814362977afb70a3d079d6,
title = "A pelvic motion driven electrical stimulator for drop-foot treatment",
abstract = "Foot switches operating with force sensitive resistors placed in the shoe sole were considered as an effective way for driving FES assisted walking systems in gait restoration. However, the reliability and durability of the foot switches run down after a certain number of steps. As an alternative for foot switches, a simple, portable, and easy to handle motion driven electrical stimulator (ES) is provided for drop foot treatment. The device is equipped with a single tri-axis accelerometer worn on the pelvis, a commercial dual channel electrical stimulator, and a controller unit. By monitoring the pelvic rotation and acceleration during a walking cycle, the events including heel strike and toe off of each step is thereby predicted by a post-processing neural network model.",
author = "Chen, {Shih Wei} and Chen, {Shih Ching} and Chen, {Chiun Fan} and Lai, {Jin Shin} and Kuo, {Te Son}",
year = "2009",
doi = "10.1109/IEMBS.2009.5333671",
language = "English",
isbn = "9781424432967",
pages = "666--669",
booktitle = "Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009",

}

TY - GEN

T1 - A pelvic motion driven electrical stimulator for drop-foot treatment

AU - Chen, Shih Wei

AU - Chen, Shih Ching

AU - Chen, Chiun Fan

AU - Lai, Jin Shin

AU - Kuo, Te Son

PY - 2009

Y1 - 2009

N2 - Foot switches operating with force sensitive resistors placed in the shoe sole were considered as an effective way for driving FES assisted walking systems in gait restoration. However, the reliability and durability of the foot switches run down after a certain number of steps. As an alternative for foot switches, a simple, portable, and easy to handle motion driven electrical stimulator (ES) is provided for drop foot treatment. The device is equipped with a single tri-axis accelerometer worn on the pelvis, a commercial dual channel electrical stimulator, and a controller unit. By monitoring the pelvic rotation and acceleration during a walking cycle, the events including heel strike and toe off of each step is thereby predicted by a post-processing neural network model.

AB - Foot switches operating with force sensitive resistors placed in the shoe sole were considered as an effective way for driving FES assisted walking systems in gait restoration. However, the reliability and durability of the foot switches run down after a certain number of steps. As an alternative for foot switches, a simple, portable, and easy to handle motion driven electrical stimulator (ES) is provided for drop foot treatment. The device is equipped with a single tri-axis accelerometer worn on the pelvis, a commercial dual channel electrical stimulator, and a controller unit. By monitoring the pelvic rotation and acceleration during a walking cycle, the events including heel strike and toe off of each step is thereby predicted by a post-processing neural network model.

UR - http://www.scopus.com/inward/record.url?scp=77951001651&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951001651&partnerID=8YFLogxK

U2 - 10.1109/IEMBS.2009.5333671

DO - 10.1109/IEMBS.2009.5333671

M3 - Conference contribution

SN - 9781424432967

SP - 666

EP - 669

BT - Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009

ER -