A novel bubble-mixture method to improve dynamic images in carbon dioxide angiography

Te I. Chang, Chih Yang Chan, Shing Kuan Su, Shoei Shen Wang, I. Hui Wu

研究成果: 雜誌貢獻文章

5 引文 (Scopus)

摘要

Purpose: To present a novel method of preparing carbon dioxide (CO2) for contrast enhancement.Technique: CO2 angiography can often produce poor image enhancement, especially in dependent vessels due to buoyancy of the gas. A new technique for premixing the CO2 gas with the patient's blood and dispersing it into the bubble mixture before injection was developed. Comparative dynamic images showed bubble-mixed CO2 angiography had less fragmentation, more even distribution, and more sustainability than the same volume of pure CO2. Conclusion: The alteration of CO2 gas toward a semiliquid form demonstrates an easy and reproducible concept to improve the dynamic image quality of traditional CO2 angiography.

原文英語
頁(從 - 到)564-567
頁數4
期刊Journal of Endovascular Therapy
22
發行號4
DOIs
出版狀態已發佈 - 八月 1 2015

指紋

Carbon Dioxide
Angiography
Gases
Image Enhancement
Injections

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

引用此文

A novel bubble-mixture method to improve dynamic images in carbon dioxide angiography. / Chang, Te I.; Chan, Chih Yang; Su, Shing Kuan; Wang, Shoei Shen; Wu, I. Hui.

於: Journal of Endovascular Therapy, 卷 22, 編號 4, 01.08.2015, p. 564-567.

研究成果: 雜誌貢獻文章

Chang, Te I. ; Chan, Chih Yang ; Su, Shing Kuan ; Wang, Shoei Shen ; Wu, I. Hui. / A novel bubble-mixture method to improve dynamic images in carbon dioxide angiography. 於: Journal of Endovascular Therapy. 2015 ; 卷 22, 編號 4. 頁 564-567.
@article{426b117a777841a6af5b7794b4fddd80,
title = "A novel bubble-mixture method to improve dynamic images in carbon dioxide angiography",
abstract = "Purpose: To present a novel method of preparing carbon dioxide (CO2) for contrast enhancement.Technique: CO2 angiography can often produce poor image enhancement, especially in dependent vessels due to buoyancy of the gas. A new technique for premixing the CO2 gas with the patient's blood and dispersing it into the bubble mixture before injection was developed. Comparative dynamic images showed bubble-mixed CO2 angiography had less fragmentation, more even distribution, and more sustainability than the same volume of pure CO2. Conclusion: The alteration of CO2 gas toward a semiliquid form demonstrates an easy and reproducible concept to improve the dynamic image quality of traditional CO2 angiography.",
keywords = "Carbon dioxide, Catheterization, Digital subtraction angiography, Endovascular techniques, Peripheral angiography, Renal insufficiency",
author = "Chang, {Te I.} and Chan, {Chih Yang} and Su, {Shing Kuan} and Wang, {Shoei Shen} and Wu, {I. Hui}",
year = "2015",
month = "8",
day = "1",
doi = "10.1177/1526602815590350",
language = "English",
volume = "22",
pages = "564--567",
journal = "Journal of Endovascular Therapy",
issn = "1526-6028",
publisher = "International Society of Endovascular Specialists",
number = "4",

}

TY - JOUR

T1 - A novel bubble-mixture method to improve dynamic images in carbon dioxide angiography

AU - Chang, Te I.

AU - Chan, Chih Yang

AU - Su, Shing Kuan

AU - Wang, Shoei Shen

AU - Wu, I. Hui

PY - 2015/8/1

Y1 - 2015/8/1

N2 - Purpose: To present a novel method of preparing carbon dioxide (CO2) for contrast enhancement.Technique: CO2 angiography can often produce poor image enhancement, especially in dependent vessels due to buoyancy of the gas. A new technique for premixing the CO2 gas with the patient's blood and dispersing it into the bubble mixture before injection was developed. Comparative dynamic images showed bubble-mixed CO2 angiography had less fragmentation, more even distribution, and more sustainability than the same volume of pure CO2. Conclusion: The alteration of CO2 gas toward a semiliquid form demonstrates an easy and reproducible concept to improve the dynamic image quality of traditional CO2 angiography.

AB - Purpose: To present a novel method of preparing carbon dioxide (CO2) for contrast enhancement.Technique: CO2 angiography can often produce poor image enhancement, especially in dependent vessels due to buoyancy of the gas. A new technique for premixing the CO2 gas with the patient's blood and dispersing it into the bubble mixture before injection was developed. Comparative dynamic images showed bubble-mixed CO2 angiography had less fragmentation, more even distribution, and more sustainability than the same volume of pure CO2. Conclusion: The alteration of CO2 gas toward a semiliquid form demonstrates an easy and reproducible concept to improve the dynamic image quality of traditional CO2 angiography.

KW - Carbon dioxide

KW - Catheterization

KW - Digital subtraction angiography

KW - Endovascular techniques

KW - Peripheral angiography

KW - Renal insufficiency

UR - http://www.scopus.com/inward/record.url?scp=84940205607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940205607&partnerID=8YFLogxK

U2 - 10.1177/1526602815590350

DO - 10.1177/1526602815590350

M3 - Article

VL - 22

SP - 564

EP - 567

JO - Journal of Endovascular Therapy

JF - Journal of Endovascular Therapy

SN - 1526-6028

IS - 4