A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design

Hsuan Shen, Yi Hsiang Yang, Chi Chang Wu, Shung Ting Sune, Yaw Chern Lee, Sung Shine Lee, Wen Chih Zhang, Yi Shen Shih, Sheng Chieh Huang, Yu Chieh Huang, Lei Chun Chou

研究成果: 書貢獻/報告類型會議貢獻

1 引文 (Scopus)

摘要

Microcirculatory dysfunction plays a key role in the patho-physiology of various disease states. The microcirculation in the skin is in a rather complicated. With technical advances, microcirculatory monitoring nowadays becomes more and more available for application in clinical practice. The proposed cosmetic chip platform based on the photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the micro-vascular bed of tissue.

原文英語
主出版物標題ICS 2010 - International Computer Symposium
頁面942-947
頁數6
DOIs
出版狀態已發佈 - 2010
對外發佈Yes
事件2010 International Computer Symposium, ICS 2010 - Tainan, 臺灣
持續時間: 十二月 16 2010十二月 18 2010

其他

其他2010 International Computer Symposium, ICS 2010
國家臺灣
城市Tainan
期間12/16/1012/18/10

指紋

Photoplethysmography
Microcirculation
Cosmetics
Physiology
Skin
Blood
Tissue
Monitoring
Costs

ASJC Scopus subject areas

  • Computer Science(all)

引用此文

Shen, H., Yang, Y. H., Wu, C. C., Sune, S. T., Lee, Y. C., Lee, S. S., ... Chou, L. C. (2010). A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design. 於 ICS 2010 - International Computer Symposium (頁 942-947). [5685374] https://doi.org/10.1109/COMPSYM.2010.5685374

A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design. / Shen, Hsuan; Yang, Yi Hsiang; Wu, Chi Chang; Sune, Shung Ting; Lee, Yaw Chern; Lee, Sung Shine; Zhang, Wen Chih; Shih, Yi Shen; Huang, Sheng Chieh; Huang, Yu Chieh; Chou, Lei Chun.

ICS 2010 - International Computer Symposium. 2010. p. 942-947 5685374.

研究成果: 書貢獻/報告類型會議貢獻

Shen, H, Yang, YH, Wu, CC, Sune, ST, Lee, YC, Lee, SS, Zhang, WC, Shih, YS, Huang, SC, Huang, YC & Chou, LC 2010, A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design. 於 ICS 2010 - International Computer Symposium., 5685374, 頁 942-947, 2010 International Computer Symposium, ICS 2010, Tainan, 臺灣, 12/16/10. https://doi.org/10.1109/COMPSYM.2010.5685374
Shen H, Yang YH, Wu CC, Sune ST, Lee YC, Lee SS 等. A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design. 於 ICS 2010 - International Computer Symposium. 2010. p. 942-947. 5685374 https://doi.org/10.1109/COMPSYM.2010.5685374
Shen, Hsuan ; Yang, Yi Hsiang ; Wu, Chi Chang ; Sune, Shung Ting ; Lee, Yaw Chern ; Lee, Sung Shine ; Zhang, Wen Chih ; Shih, Yi Shen ; Huang, Sheng Chieh ; Huang, Yu Chieh ; Chou, Lei Chun. / A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design. ICS 2010 - International Computer Symposium. 2010. 頁 942-947
@inproceedings{1d92c05c33f3466fbc3704f4a447d4cb,
title = "A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design",
abstract = "Microcirculatory dysfunction plays a key role in the patho-physiology of various disease states. The microcirculation in the skin is in a rather complicated. With technical advances, microcirculatory monitoring nowadays becomes more and more available for application in clinical practice. The proposed cosmetic chip platform based on the photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the micro-vascular bed of tissue.",
keywords = "Component, Cosmetic chip, Microcirculation, PPG",
author = "Hsuan Shen and Yang, {Yi Hsiang} and Wu, {Chi Chang} and Sune, {Shung Ting} and Lee, {Yaw Chern} and Lee, {Sung Shine} and Zhang, {Wen Chih} and Shih, {Yi Shen} and Huang, {Sheng Chieh} and Huang, {Yu Chieh} and Chou, {Lei Chun}",
year = "2010",
doi = "10.1109/COMPSYM.2010.5685374",
language = "English",
isbn = "9781424476404",
pages = "942--947",
booktitle = "ICS 2010 - International Computer Symposium",

}

TY - GEN

T1 - A novel 500 samples/sec 4 by 4 photoplethysmography (PPG) array based cosmetic chip design

AU - Shen, Hsuan

AU - Yang, Yi Hsiang

AU - Wu, Chi Chang

AU - Sune, Shung Ting

AU - Lee, Yaw Chern

AU - Lee, Sung Shine

AU - Zhang, Wen Chih

AU - Shih, Yi Shen

AU - Huang, Sheng Chieh

AU - Huang, Yu Chieh

AU - Chou, Lei Chun

PY - 2010

Y1 - 2010

N2 - Microcirculatory dysfunction plays a key role in the patho-physiology of various disease states. The microcirculation in the skin is in a rather complicated. With technical advances, microcirculatory monitoring nowadays becomes more and more available for application in clinical practice. The proposed cosmetic chip platform based on the photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the micro-vascular bed of tissue.

AB - Microcirculatory dysfunction plays a key role in the patho-physiology of various disease states. The microcirculation in the skin is in a rather complicated. With technical advances, microcirculatory monitoring nowadays becomes more and more available for application in clinical practice. The proposed cosmetic chip platform based on the photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the micro-vascular bed of tissue.

KW - Component

KW - Cosmetic chip

KW - Microcirculation

KW - PPG

UR - http://www.scopus.com/inward/record.url?scp=79851502871&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79851502871&partnerID=8YFLogxK

U2 - 10.1109/COMPSYM.2010.5685374

DO - 10.1109/COMPSYM.2010.5685374

M3 - Conference contribution

AN - SCOPUS:79851502871

SN - 9781424476404

SP - 942

EP - 947

BT - ICS 2010 - International Computer Symposium

ER -