Vascular space occupancy-dependent functional MRI by tissue suppression

Changwei W. Wu, Kai Hsiang Chuang, Yau Yau Wai, Yung Liang Wan, Jyh Horng Chen, Ho Ling Liu

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Purpose: To measure the cerebral blood volume (CBV) dynamics during neural activation, a novel technique named vascular space occupancy (VASO)-based functional MRI (fMRI) was recently introduced for noninvasive CBV detection. However, its application is limited because of its low contrast-to-noise ratio (CNR) due to small signal change from the inverted blood. Materials and Methods: In this study a new approach-VASO with tissue suppression (VAST) - is proposed to enhance CNR. This technique is compared with VASO and blood oxygenation level-dependent (BOLD) fMRI in block-design and event-related visual experiments. Results: Based on acquired T1 maps, 75.3% of the activated pixels detected by VAST are located in the cortical gray matter. Temporal characteristics of functional responses obtained by VAST were consistent with that of VASO. Although the baseline signal was decreased by the tissue suppression, the CNR of VAST was about 43% higher than VASO. Conclusion: With the improved sensitivity, VAST fMRI provides a useful alternative for mapping the spatial/temporal features of regional CBV changes during brain activation. However, the technical imperfectness of VAST, such as the nonideal inversion efficiency and physiological contaminations, limits its application to precise CBV quantification.

Original languageEnglish
Pages (from-to)219-226
Number of pages8
JournalJournal of Magnetic Resonance Imaging
Volume28
Issue number1
DOIs
Publication statusPublished - Jul 1 2008
Externally publishedYes

Fingerprint

Blood Vessels
Magnetic Resonance Imaging
Noise
Cerebral Blood Volume
Brain

Keywords

  • BOLD
  • Cerebral blood volume
  • Functional MRI
  • Tissue suppression
  • VASO

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Vascular space occupancy-dependent functional MRI by tissue suppression. / Wu, Changwei W.; Chuang, Kai Hsiang; Wai, Yau Yau; Wan, Yung Liang; Chen, Jyh Horng; Liu, Ho Ling.

In: Journal of Magnetic Resonance Imaging, Vol. 28, No. 1, 01.07.2008, p. 219-226.

Research output: Contribution to journalArticle

Wu, Changwei W. ; Chuang, Kai Hsiang ; Wai, Yau Yau ; Wan, Yung Liang ; Chen, Jyh Horng ; Liu, Ho Ling. / Vascular space occupancy-dependent functional MRI by tissue suppression. In: Journal of Magnetic Resonance Imaging. 2008 ; Vol. 28, No. 1. pp. 219-226.
@article{ce20d70dad5f4cc69284d3d782efe879,
title = "Vascular space occupancy-dependent functional MRI by tissue suppression",
abstract = "Purpose: To measure the cerebral blood volume (CBV) dynamics during neural activation, a novel technique named vascular space occupancy (VASO)-based functional MRI (fMRI) was recently introduced for noninvasive CBV detection. However, its application is limited because of its low contrast-to-noise ratio (CNR) due to small signal change from the inverted blood. Materials and Methods: In this study a new approach-VASO with tissue suppression (VAST) - is proposed to enhance CNR. This technique is compared with VASO and blood oxygenation level-dependent (BOLD) fMRI in block-design and event-related visual experiments. Results: Based on acquired T1 maps, 75.3{\%} of the activated pixels detected by VAST are located in the cortical gray matter. Temporal characteristics of functional responses obtained by VAST were consistent with that of VASO. Although the baseline signal was decreased by the tissue suppression, the CNR of VAST was about 43{\%} higher than VASO. Conclusion: With the improved sensitivity, VAST fMRI provides a useful alternative for mapping the spatial/temporal features of regional CBV changes during brain activation. However, the technical imperfectness of VAST, such as the nonideal inversion efficiency and physiological contaminations, limits its application to precise CBV quantification.",
keywords = "BOLD, Cerebral blood volume, Functional MRI, Tissue suppression, VASO",
author = "Wu, {Changwei W.} and Chuang, {Kai Hsiang} and Wai, {Yau Yau} and Wan, {Yung Liang} and Chen, {Jyh Horng} and Liu, {Ho Ling}",
year = "2008",
month = "7",
day = "1",
doi = "10.1002/jmri.21410",
language = "English",
volume = "28",
pages = "219--226",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Vascular space occupancy-dependent functional MRI by tissue suppression

AU - Wu, Changwei W.

AU - Chuang, Kai Hsiang

AU - Wai, Yau Yau

AU - Wan, Yung Liang

AU - Chen, Jyh Horng

AU - Liu, Ho Ling

PY - 2008/7/1

Y1 - 2008/7/1

N2 - Purpose: To measure the cerebral blood volume (CBV) dynamics during neural activation, a novel technique named vascular space occupancy (VASO)-based functional MRI (fMRI) was recently introduced for noninvasive CBV detection. However, its application is limited because of its low contrast-to-noise ratio (CNR) due to small signal change from the inverted blood. Materials and Methods: In this study a new approach-VASO with tissue suppression (VAST) - is proposed to enhance CNR. This technique is compared with VASO and blood oxygenation level-dependent (BOLD) fMRI in block-design and event-related visual experiments. Results: Based on acquired T1 maps, 75.3% of the activated pixels detected by VAST are located in the cortical gray matter. Temporal characteristics of functional responses obtained by VAST were consistent with that of VASO. Although the baseline signal was decreased by the tissue suppression, the CNR of VAST was about 43% higher than VASO. Conclusion: With the improved sensitivity, VAST fMRI provides a useful alternative for mapping the spatial/temporal features of regional CBV changes during brain activation. However, the technical imperfectness of VAST, such as the nonideal inversion efficiency and physiological contaminations, limits its application to precise CBV quantification.

AB - Purpose: To measure the cerebral blood volume (CBV) dynamics during neural activation, a novel technique named vascular space occupancy (VASO)-based functional MRI (fMRI) was recently introduced for noninvasive CBV detection. However, its application is limited because of its low contrast-to-noise ratio (CNR) due to small signal change from the inverted blood. Materials and Methods: In this study a new approach-VASO with tissue suppression (VAST) - is proposed to enhance CNR. This technique is compared with VASO and blood oxygenation level-dependent (BOLD) fMRI in block-design and event-related visual experiments. Results: Based on acquired T1 maps, 75.3% of the activated pixels detected by VAST are located in the cortical gray matter. Temporal characteristics of functional responses obtained by VAST were consistent with that of VASO. Although the baseline signal was decreased by the tissue suppression, the CNR of VAST was about 43% higher than VASO. Conclusion: With the improved sensitivity, VAST fMRI provides a useful alternative for mapping the spatial/temporal features of regional CBV changes during brain activation. However, the technical imperfectness of VAST, such as the nonideal inversion efficiency and physiological contaminations, limits its application to precise CBV quantification.

KW - BOLD

KW - Cerebral blood volume

KW - Functional MRI

KW - Tissue suppression

KW - VASO

UR - http://www.scopus.com/inward/record.url?scp=46849084108&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=46849084108&partnerID=8YFLogxK

U2 - 10.1002/jmri.21410

DO - 10.1002/jmri.21410

M3 - Article

C2 - 18581345

AN - SCOPUS:46849084108

VL - 28

SP - 219

EP - 226

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 1

ER -