VALIDATION DES PROPRIETES RHEOLOGIQUES D'UNE COLLE DE FIBRINE

LE BIOCOL®-THROMBINE HUMAINE

Translated title of the contribution: Validation of the rheological properties of a fibrin glue: Biocol®-Thrombine Humaine

P. Duval, B. Flan, T. Burnouf, J. J. Huart

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Rheological properties of one of the main fibrin glues, 'Biocol-Thrombine Humaine', prepared by the Regional Blood Transfusion Center of Lille (France) were measured with a CSL controlled stress rheometer using cone-plates and parallel plates. The parameters followed were the dynamic viscosity of the fibrinogen concentrate, the gelification time, the breaking point in a destructive test and the development of elasticity of the fibrin clots according to time or frequency. The results showed that the fibrinogen concentrate of 'Biocol-Thrombine Humaine' has a flow curve near that of Newtonian flow, and that its dynamic viscosity at 20 °C is about 100 mPa.s. The gelification time of the fibrinogen-thrombin mixture is very short (under 10 seconds). The breaking point is high, showing a great strength of the fibrin clots. The development of elasticity after mixing is very quick. It is also independent of the frequency shearing. The validation of these rheological tests provides data supporting their use in the assessment of the physical properties of fibrin glue in place of the currently used test based on the gluing of mouse skin.

Original languageFrench
Pages (from-to)43-52
Number of pages10
JournalAnnales Pharmaceutiques Francaises
Volume52
Issue number1
Publication statusPublished - 1994
Externally publishedYes

Fingerprint

Fibrin Tissue Adhesive
Fibrinogen
Elasticity
Fibrin
Viscosity
Thrombin Time
Blood Transfusion
France
Skin

ASJC Scopus subject areas

  • Pharmaceutical Science

Cite this

VALIDATION DES PROPRIETES RHEOLOGIQUES D'UNE COLLE DE FIBRINE : LE BIOCOL®-THROMBINE HUMAINE. / Duval, P.; Flan, B.; Burnouf, T.; Huart, J. J.

In: Annales Pharmaceutiques Francaises, Vol. 52, No. 1, 1994, p. 43-52.

Research output: Contribution to journalArticle

@article{3f62ea62563b47c3a0d25979361c65c4,
title = "VALIDATION DES PROPRIETES RHEOLOGIQUES D'UNE COLLE DE FIBRINE: LE BIOCOL{\circledR}-THROMBINE HUMAINE",
abstract = "Rheological properties of one of the main fibrin glues, 'Biocol-Thrombine Humaine', prepared by the Regional Blood Transfusion Center of Lille (France) were measured with a CSL controlled stress rheometer using cone-plates and parallel plates. The parameters followed were the dynamic viscosity of the fibrinogen concentrate, the gelification time, the breaking point in a destructive test and the development of elasticity of the fibrin clots according to time or frequency. The results showed that the fibrinogen concentrate of 'Biocol-Thrombine Humaine' has a flow curve near that of Newtonian flow, and that its dynamic viscosity at 20 °C is about 100 mPa.s. The gelification time of the fibrinogen-thrombin mixture is very short (under 10 seconds). The breaking point is high, showing a great strength of the fibrin clots. The development of elasticity after mixing is very quick. It is also independent of the frequency shearing. The validation of these rheological tests provides data supporting their use in the assessment of the physical properties of fibrin glue in place of the currently used test based on the gluing of mouse skin.",
author = "P. Duval and B. Flan and T. Burnouf and Huart, {J. J.}",
year = "1994",
language = "法语",
volume = "52",
pages = "43--52",
journal = "Annales Pharmaceutiques Francaises",
issn = "0003-4509",
publisher = "Elsevier Masson",
number = "1",

}

TY - JOUR

T1 - VALIDATION DES PROPRIETES RHEOLOGIQUES D'UNE COLLE DE FIBRINE

T2 - LE BIOCOL®-THROMBINE HUMAINE

AU - Duval, P.

AU - Flan, B.

AU - Burnouf, T.

AU - Huart, J. J.

PY - 1994

Y1 - 1994

N2 - Rheological properties of one of the main fibrin glues, 'Biocol-Thrombine Humaine', prepared by the Regional Blood Transfusion Center of Lille (France) were measured with a CSL controlled stress rheometer using cone-plates and parallel plates. The parameters followed were the dynamic viscosity of the fibrinogen concentrate, the gelification time, the breaking point in a destructive test and the development of elasticity of the fibrin clots according to time or frequency. The results showed that the fibrinogen concentrate of 'Biocol-Thrombine Humaine' has a flow curve near that of Newtonian flow, and that its dynamic viscosity at 20 °C is about 100 mPa.s. The gelification time of the fibrinogen-thrombin mixture is very short (under 10 seconds). The breaking point is high, showing a great strength of the fibrin clots. The development of elasticity after mixing is very quick. It is also independent of the frequency shearing. The validation of these rheological tests provides data supporting their use in the assessment of the physical properties of fibrin glue in place of the currently used test based on the gluing of mouse skin.

AB - Rheological properties of one of the main fibrin glues, 'Biocol-Thrombine Humaine', prepared by the Regional Blood Transfusion Center of Lille (France) were measured with a CSL controlled stress rheometer using cone-plates and parallel plates. The parameters followed were the dynamic viscosity of the fibrinogen concentrate, the gelification time, the breaking point in a destructive test and the development of elasticity of the fibrin clots according to time or frequency. The results showed that the fibrinogen concentrate of 'Biocol-Thrombine Humaine' has a flow curve near that of Newtonian flow, and that its dynamic viscosity at 20 °C is about 100 mPa.s. The gelification time of the fibrinogen-thrombin mixture is very short (under 10 seconds). The breaking point is high, showing a great strength of the fibrin clots. The development of elasticity after mixing is very quick. It is also independent of the frequency shearing. The validation of these rheological tests provides data supporting their use in the assessment of the physical properties of fibrin glue in place of the currently used test based on the gluing of mouse skin.

UR - http://www.scopus.com/inward/record.url?scp=0028188739&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028188739&partnerID=8YFLogxK

M3 - 文章

VL - 52

SP - 43

EP - 52

JO - Annales Pharmaceutiques Francaises

JF - Annales Pharmaceutiques Francaises

SN - 0003-4509

IS - 1