Using the Matrix-Induced Ion Suppression Method for Concentration Normalization in Cellular Metabolomics Studies

Guan Yuan Chen, Hsiao Wei Liao, I. Lin Tsai, Yufeng Jane Tseng, Ching Hua Kuo

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Studies of the cell metabolome greatly improve our understanding of cell biology. Currently, most cellular metabolomics studies control only cell numbers or protein content without adjusting the total metabolite concentration, mainly because of the lack of an effective concentration normalization method for cell metabolites. This study proposed a matrix-induced ion suppression (MIIS) method to measure the total amount of cellular metabolites by utilizing flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS).We used series dilutions of HL-60 cell extracts to establish the relationship between cellular metabolite concentration and the degree of ion suppression of the ion suppression indicator, and a good correlation was obtained between 2- and 12-fold dilutions of cell extracts (R2 = 0.999). Two lung cancer cells, CL1-0 and CL1-5, were selected as the model cell lines to evaluate the efficacy of the MIIS method and the importance of metabolite concentration normalization. Through MIIS analysis, CL1-0 cells were found to contain metabolites at a concentration 2.1 times higher than in CL1-5, and the metastatic properties of CL1-5 could only be observed after 2.1-fold dilution of CL1-0 before metabolomic analysis. Our results demonstrated that the MIIS method is an effective approach for metabolite concentration normalization and that controlling metabolite concentrations can improve data integrity in cellular metabolomics studies.

Original languageEnglish
Pages (from-to)9731-9739
Number of pages9
JournalAnalytical Chemistry
Volume87
Issue number19
DOIs
Publication statusPublished - Oct 6 2015
Externally publishedYes

Fingerprint

Metabolites
Ions
Dilution
Cells
Cytology
Electrospray ionization
Metabolomics
Mass spectrometry

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Using the Matrix-Induced Ion Suppression Method for Concentration Normalization in Cellular Metabolomics Studies. / Chen, Guan Yuan; Liao, Hsiao Wei; Tsai, I. Lin; Tseng, Yufeng Jane; Kuo, Ching Hua.

In: Analytical Chemistry, Vol. 87, No. 19, 06.10.2015, p. 9731-9739.

Research output: Contribution to journalArticle

Chen, Guan Yuan ; Liao, Hsiao Wei ; Tsai, I. Lin ; Tseng, Yufeng Jane ; Kuo, Ching Hua. / Using the Matrix-Induced Ion Suppression Method for Concentration Normalization in Cellular Metabolomics Studies. In: Analytical Chemistry. 2015 ; Vol. 87, No. 19. pp. 9731-9739.
@article{d30217686ff04ed1bc8f399ef866486f,
title = "Using the Matrix-Induced Ion Suppression Method for Concentration Normalization in Cellular Metabolomics Studies",
abstract = "Studies of the cell metabolome greatly improve our understanding of cell biology. Currently, most cellular metabolomics studies control only cell numbers or protein content without adjusting the total metabolite concentration, mainly because of the lack of an effective concentration normalization method for cell metabolites. This study proposed a matrix-induced ion suppression (MIIS) method to measure the total amount of cellular metabolites by utilizing flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS).We used series dilutions of HL-60 cell extracts to establish the relationship between cellular metabolite concentration and the degree of ion suppression of the ion suppression indicator, and a good correlation was obtained between 2- and 12-fold dilutions of cell extracts (R2 = 0.999). Two lung cancer cells, CL1-0 and CL1-5, were selected as the model cell lines to evaluate the efficacy of the MIIS method and the importance of metabolite concentration normalization. Through MIIS analysis, CL1-0 cells were found to contain metabolites at a concentration 2.1 times higher than in CL1-5, and the metastatic properties of CL1-5 could only be observed after 2.1-fold dilution of CL1-0 before metabolomic analysis. Our results demonstrated that the MIIS method is an effective approach for metabolite concentration normalization and that controlling metabolite concentrations can improve data integrity in cellular metabolomics studies.",
author = "Chen, {Guan Yuan} and Liao, {Hsiao Wei} and Tsai, {I. Lin} and Tseng, {Yufeng Jane} and Kuo, {Ching Hua}",
year = "2015",
month = "10",
day = "6",
doi = "10.1021/acs.analchem.5b01869",
language = "English",
volume = "87",
pages = "9731--9739",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "19",

}

TY - JOUR

T1 - Using the Matrix-Induced Ion Suppression Method for Concentration Normalization in Cellular Metabolomics Studies

AU - Chen, Guan Yuan

AU - Liao, Hsiao Wei

AU - Tsai, I. Lin

AU - Tseng, Yufeng Jane

AU - Kuo, Ching Hua

PY - 2015/10/6

Y1 - 2015/10/6

N2 - Studies of the cell metabolome greatly improve our understanding of cell biology. Currently, most cellular metabolomics studies control only cell numbers or protein content without adjusting the total metabolite concentration, mainly because of the lack of an effective concentration normalization method for cell metabolites. This study proposed a matrix-induced ion suppression (MIIS) method to measure the total amount of cellular metabolites by utilizing flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS).We used series dilutions of HL-60 cell extracts to establish the relationship between cellular metabolite concentration and the degree of ion suppression of the ion suppression indicator, and a good correlation was obtained between 2- and 12-fold dilutions of cell extracts (R2 = 0.999). Two lung cancer cells, CL1-0 and CL1-5, were selected as the model cell lines to evaluate the efficacy of the MIIS method and the importance of metabolite concentration normalization. Through MIIS analysis, CL1-0 cells were found to contain metabolites at a concentration 2.1 times higher than in CL1-5, and the metastatic properties of CL1-5 could only be observed after 2.1-fold dilution of CL1-0 before metabolomic analysis. Our results demonstrated that the MIIS method is an effective approach for metabolite concentration normalization and that controlling metabolite concentrations can improve data integrity in cellular metabolomics studies.

AB - Studies of the cell metabolome greatly improve our understanding of cell biology. Currently, most cellular metabolomics studies control only cell numbers or protein content without adjusting the total metabolite concentration, mainly because of the lack of an effective concentration normalization method for cell metabolites. This study proposed a matrix-induced ion suppression (MIIS) method to measure the total amount of cellular metabolites by utilizing flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS).We used series dilutions of HL-60 cell extracts to establish the relationship between cellular metabolite concentration and the degree of ion suppression of the ion suppression indicator, and a good correlation was obtained between 2- and 12-fold dilutions of cell extracts (R2 = 0.999). Two lung cancer cells, CL1-0 and CL1-5, were selected as the model cell lines to evaluate the efficacy of the MIIS method and the importance of metabolite concentration normalization. Through MIIS analysis, CL1-0 cells were found to contain metabolites at a concentration 2.1 times higher than in CL1-5, and the metastatic properties of CL1-5 could only be observed after 2.1-fold dilution of CL1-0 before metabolomic analysis. Our results demonstrated that the MIIS method is an effective approach for metabolite concentration normalization and that controlling metabolite concentrations can improve data integrity in cellular metabolomics studies.

UR - http://www.scopus.com/inward/record.url?scp=84943166895&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84943166895&partnerID=8YFLogxK

U2 - 10.1021/acs.analchem.5b01869

DO - 10.1021/acs.analchem.5b01869

M3 - Article

C2 - 26359637

AN - SCOPUS:84943166895

VL - 87

SP - 9731

EP - 9739

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 19

ER -