Using porous polyethylene implant for maxillofacial bony reconstruction - A general introduction and case report of a complication

Thomas Mon Hsian Hsieh, Chao Hsiang Lee, Yueh Bih Tang, I. Jen Chiang, Jau Min Wong

Research output: Contribution to journalArticle

Abstract

Reconstruction of facial defect is always a challenging task for plastic surgeons. Using either autogenous tissue or alloplastic material has its own merits and demerits and the decision making depends not only on the experience of the surgeon but also on the selection of the patients. Alloplastic implant made of high-density porous polyethylene has been widely used in craniofacial reconstruction in recent years. It shows long-term stability, high tensile strength, and minimal tissue reaction. Its unique porous system facilitates tissue ingrowth, which enhances the implant fixation, therefore, it decreases the chance of migration, extrusion, and capsule formation. Here we presented our experience of using porous polyethylene implant in our hospital, the surgical technique used for implant insertion. Finally, a case of complication was presented to discuss the use of these implants in particular situations, such as previous irradiation. It is concluded that implant made of porous polyethylene is an ideal material for maxillofacial reconstruction; however, careful patient selection is needed. Tissue with history of previous irradiation may have the risk of poor tissue healing. Careful assessment and more scientific and reliable methods are still being sought to solve these problems.

Original languageEnglish
Pages (from-to)239-244
Number of pages6
JournalBiomedical Engineering - Applications, Basis and Communications
Volume21
Issue number4
DOIs
Publication statusPublished - Aug 2009

Fingerprint

Polyethylene
Polyethylenes
Tissue
Patient Selection
Irradiation
Tensile Strength
Capsules
Extrusion
Decision Making
Tensile strength
Decision making
Defects
Surgeons

Keywords

  • Alloplastic implant
  • Maxilla reconstruction
  • Medpor

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering
  • Bioengineering

Cite this

Using porous polyethylene implant for maxillofacial bony reconstruction - A general introduction and case report of a complication. / Hsieh, Thomas Mon Hsian; Lee, Chao Hsiang; Tang, Yueh Bih; Chiang, I. Jen; Wong, Jau Min.

In: Biomedical Engineering - Applications, Basis and Communications, Vol. 21, No. 4, 08.2009, p. 239-244.

Research output: Contribution to journalArticle

Hsieh, Thomas Mon Hsian ; Lee, Chao Hsiang ; Tang, Yueh Bih ; Chiang, I. Jen ; Wong, Jau Min. / Using porous polyethylene implant for maxillofacial bony reconstruction - A general introduction and case report of a complication. In: Biomedical Engineering - Applications, Basis and Communications. 2009 ; Vol. 21, No. 4. pp. 239-244.
@article{97f5852dfd6f4abca70e2b42dc684abf,
title = "Using porous polyethylene implant for maxillofacial bony reconstruction - A general introduction and case report of a complication",
abstract = "Reconstruction of facial defect is always a challenging task for plastic surgeons. Using either autogenous tissue or alloplastic material has its own merits and demerits and the decision making depends not only on the experience of the surgeon but also on the selection of the patients. Alloplastic implant made of high-density porous polyethylene has been widely used in craniofacial reconstruction in recent years. It shows long-term stability, high tensile strength, and minimal tissue reaction. Its unique porous system facilitates tissue ingrowth, which enhances the implant fixation, therefore, it decreases the chance of migration, extrusion, and capsule formation. Here we presented our experience of using porous polyethylene implant in our hospital, the surgical technique used for implant insertion. Finally, a case of complication was presented to discuss the use of these implants in particular situations, such as previous irradiation. It is concluded that implant made of porous polyethylene is an ideal material for maxillofacial reconstruction; however, careful patient selection is needed. Tissue with history of previous irradiation may have the risk of poor tissue healing. Careful assessment and more scientific and reliable methods are still being sought to solve these problems.",
keywords = "Alloplastic implant, Maxilla reconstruction, Medpor",
author = "Hsieh, {Thomas Mon Hsian} and Lee, {Chao Hsiang} and Tang, {Yueh Bih} and Chiang, {I. Jen} and Wong, {Jau Min}",
year = "2009",
month = "8",
doi = "10.4015/S1016237209001349",
language = "English",
volume = "21",
pages = "239--244",
journal = "Journal of Chinese Corrosion Engineering",
issn = "1016-2372",
publisher = "World Scientific Publishing Co. Pte Ltd",
number = "4",

}

TY - JOUR

T1 - Using porous polyethylene implant for maxillofacial bony reconstruction - A general introduction and case report of a complication

AU - Hsieh, Thomas Mon Hsian

AU - Lee, Chao Hsiang

AU - Tang, Yueh Bih

AU - Chiang, I. Jen

AU - Wong, Jau Min

PY - 2009/8

Y1 - 2009/8

N2 - Reconstruction of facial defect is always a challenging task for plastic surgeons. Using either autogenous tissue or alloplastic material has its own merits and demerits and the decision making depends not only on the experience of the surgeon but also on the selection of the patients. Alloplastic implant made of high-density porous polyethylene has been widely used in craniofacial reconstruction in recent years. It shows long-term stability, high tensile strength, and minimal tissue reaction. Its unique porous system facilitates tissue ingrowth, which enhances the implant fixation, therefore, it decreases the chance of migration, extrusion, and capsule formation. Here we presented our experience of using porous polyethylene implant in our hospital, the surgical technique used for implant insertion. Finally, a case of complication was presented to discuss the use of these implants in particular situations, such as previous irradiation. It is concluded that implant made of porous polyethylene is an ideal material for maxillofacial reconstruction; however, careful patient selection is needed. Tissue with history of previous irradiation may have the risk of poor tissue healing. Careful assessment and more scientific and reliable methods are still being sought to solve these problems.

AB - Reconstruction of facial defect is always a challenging task for plastic surgeons. Using either autogenous tissue or alloplastic material has its own merits and demerits and the decision making depends not only on the experience of the surgeon but also on the selection of the patients. Alloplastic implant made of high-density porous polyethylene has been widely used in craniofacial reconstruction in recent years. It shows long-term stability, high tensile strength, and minimal tissue reaction. Its unique porous system facilitates tissue ingrowth, which enhances the implant fixation, therefore, it decreases the chance of migration, extrusion, and capsule formation. Here we presented our experience of using porous polyethylene implant in our hospital, the surgical technique used for implant insertion. Finally, a case of complication was presented to discuss the use of these implants in particular situations, such as previous irradiation. It is concluded that implant made of porous polyethylene is an ideal material for maxillofacial reconstruction; however, careful patient selection is needed. Tissue with history of previous irradiation may have the risk of poor tissue healing. Careful assessment and more scientific and reliable methods are still being sought to solve these problems.

KW - Alloplastic implant

KW - Maxilla reconstruction

KW - Medpor

UR - http://www.scopus.com/inward/record.url?scp=69049095018&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=69049095018&partnerID=8YFLogxK

U2 - 10.4015/S1016237209001349

DO - 10.4015/S1016237209001349

M3 - Article

AN - SCOPUS:69049095018

VL - 21

SP - 239

EP - 244

JO - Journal of Chinese Corrosion Engineering

JF - Journal of Chinese Corrosion Engineering

SN - 1016-2372

IS - 4

ER -