The Use of Wearable Sensors for the Movement Assessment on Muscle Contraction Sequences in Post-Stroke Patients during Sit-to-Stand

Wei Chun Hsu, Chao Chin Chang, Yi Jia Lin, Fu Chi Yang, Li Fong Lin, Kuan Nien Chou

Research output: Contribution to journalArticle

Abstract

Electromyography (EMG) sensors have been used to study the sequence of muscle contractions during sit-to-stand (STS) in post-stroke patients. However, the majority of the studies used wired sensors with a limited number of placements. Using the latest improved wearable technology with 16 sensors, the current study was a thorough investigation to evaluate the contraction sequences of eight key muscles on the trunk and bilateral limbs during STS in post-stroke patients, as it became feasible. Multiple wearable sensors for the detection of muscle contraction sequences showed that the post-stroke patients performed STS with abnormal firing sequences, not only in the primary mover on the sagittal plane during raising, but also in the tibialis anterior, which may affect anticipatory postural adjustment in the gluteus medius, which may affect balance control. The abnormal tibialis anterior contraction until the early ascending phase and the delayed firing of the gluteus muscles highlight the importance of whole-kinetic-chain monitoring of contraction sequences using wearable sensors. The findings can be helpful for the design of therapeutic exercises.

Original languageEnglish
Article number657
JournalSensors (Switzerland)
Volume19
Issue number3
DOIs
Publication statusPublished - Feb 6 2019

Fingerprint

muscular function
Muscle Contraction
strokes
Muscle
Stroke
sensors
contraction
Muscles
muscles
Electromyography
Sensors
electromyography
Extremities
Exercise
Technology
physical exercise
limbs
adjusting
Wearable sensors
Kinetics

Keywords

  • Contraction of the muscles
  • Electromyography signal
  • Sit-to-stand
  • Stroke
  • Wearable sensors
  • Humans
  • Middle Aged
  • Wearable Electronic Devices
  • Stroke/physiopathology
  • Electromyography/instrumentation
  • Male
  • Equipment Design
  • Stroke Rehabilitation/instrumentation
  • Female
  • Aged
  • Muscle Contraction/physiology
  • Muscle, Skeletal/physiology

ASJC Scopus subject areas

  • Analytical Chemistry
  • Instrumentation
  • Atomic and Molecular Physics, and Optics
  • Electrical and Electronic Engineering
  • Biochemistry

Cite this

The Use of Wearable Sensors for the Movement Assessment on Muscle Contraction Sequences in Post-Stroke Patients during Sit-to-Stand. / Hsu, Wei Chun; Chang, Chao Chin; Lin, Yi Jia; Yang, Fu Chi; Lin, Li Fong; Chou, Kuan Nien.

In: Sensors (Switzerland), Vol. 19, No. 3, 657, 06.02.2019.

Research output: Contribution to journalArticle

Hsu, Wei Chun ; Chang, Chao Chin ; Lin, Yi Jia ; Yang, Fu Chi ; Lin, Li Fong ; Chou, Kuan Nien. / The Use of Wearable Sensors for the Movement Assessment on Muscle Contraction Sequences in Post-Stroke Patients during Sit-to-Stand. In: Sensors (Switzerland). 2019 ; Vol. 19, No. 3.
@article{7bca6befbd7b4088a134c9803b18bd19,
title = "The Use of Wearable Sensors for the Movement Assessment on Muscle Contraction Sequences in Post-Stroke Patients during Sit-to-Stand",
abstract = "Electromyography (EMG) sensors have been used to study the sequence of muscle contractions during sit-to-stand (STS) in post-stroke patients. However, the majority of the studies used wired sensors with a limited number of placements. Using the latest improved wearable technology with 16 sensors, the current study was a thorough investigation to evaluate the contraction sequences of eight key muscles on the trunk and bilateral limbs during STS in post-stroke patients, as it became feasible. Multiple wearable sensors for the detection of muscle contraction sequences showed that the post-stroke patients performed STS with abnormal firing sequences, not only in the primary mover on the sagittal plane during raising, but also in the tibialis anterior, which may affect anticipatory postural adjustment in the gluteus medius, which may affect balance control. The abnormal tibialis anterior contraction until the early ascending phase and the delayed firing of the gluteus muscles highlight the importance of whole-kinetic-chain monitoring of contraction sequences using wearable sensors. The findings can be helpful for the design of therapeutic exercises.",
keywords = "Contraction of the muscles, Electromyography signal, Sit-to-stand, Stroke, Wearable sensors, Humans, Middle Aged, Wearable Electronic Devices, Stroke/physiopathology, Electromyography/instrumentation, Male, Equipment Design, Stroke Rehabilitation/instrumentation, Female, Aged, Muscle Contraction/physiology, Muscle, Skeletal/physiology",
author = "Hsu, {Wei Chun} and Chang, {Chao Chin} and Lin, {Yi Jia} and Yang, {Fu Chi} and Lin, {Li Fong} and Chou, {Kuan Nien}",
year = "2019",
month = "2",
day = "6",
doi = "10.3390/s19030657",
language = "English",
volume = "19",
journal = "Sensors",
issn = "1424-3210",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "3",

}

TY - JOUR

T1 - The Use of Wearable Sensors for the Movement Assessment on Muscle Contraction Sequences in Post-Stroke Patients during Sit-to-Stand

AU - Hsu, Wei Chun

AU - Chang, Chao Chin

AU - Lin, Yi Jia

AU - Yang, Fu Chi

AU - Lin, Li Fong

AU - Chou, Kuan Nien

PY - 2019/2/6

Y1 - 2019/2/6

N2 - Electromyography (EMG) sensors have been used to study the sequence of muscle contractions during sit-to-stand (STS) in post-stroke patients. However, the majority of the studies used wired sensors with a limited number of placements. Using the latest improved wearable technology with 16 sensors, the current study was a thorough investigation to evaluate the contraction sequences of eight key muscles on the trunk and bilateral limbs during STS in post-stroke patients, as it became feasible. Multiple wearable sensors for the detection of muscle contraction sequences showed that the post-stroke patients performed STS with abnormal firing sequences, not only in the primary mover on the sagittal plane during raising, but also in the tibialis anterior, which may affect anticipatory postural adjustment in the gluteus medius, which may affect balance control. The abnormal tibialis anterior contraction until the early ascending phase and the delayed firing of the gluteus muscles highlight the importance of whole-kinetic-chain monitoring of contraction sequences using wearable sensors. The findings can be helpful for the design of therapeutic exercises.

AB - Electromyography (EMG) sensors have been used to study the sequence of muscle contractions during sit-to-stand (STS) in post-stroke patients. However, the majority of the studies used wired sensors with a limited number of placements. Using the latest improved wearable technology with 16 sensors, the current study was a thorough investigation to evaluate the contraction sequences of eight key muscles on the trunk and bilateral limbs during STS in post-stroke patients, as it became feasible. Multiple wearable sensors for the detection of muscle contraction sequences showed that the post-stroke patients performed STS with abnormal firing sequences, not only in the primary mover on the sagittal plane during raising, but also in the tibialis anterior, which may affect anticipatory postural adjustment in the gluteus medius, which may affect balance control. The abnormal tibialis anterior contraction until the early ascending phase and the delayed firing of the gluteus muscles highlight the importance of whole-kinetic-chain monitoring of contraction sequences using wearable sensors. The findings can be helpful for the design of therapeutic exercises.

KW - Contraction of the muscles

KW - Electromyography signal

KW - Sit-to-stand

KW - Stroke

KW - Wearable sensors

KW - Humans

KW - Middle Aged

KW - Wearable Electronic Devices

KW - Stroke/physiopathology

KW - Electromyography/instrumentation

KW - Male

KW - Equipment Design

KW - Stroke Rehabilitation/instrumentation

KW - Female

KW - Aged

KW - Muscle Contraction/physiology

KW - Muscle, Skeletal/physiology

UR - http://www.scopus.com/inward/record.url?scp=85061295088&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85061295088&partnerID=8YFLogxK

U2 - 10.3390/s19030657

DO - 10.3390/s19030657

M3 - Article

C2 - 30736269

AN - SCOPUS:85061295088

VL - 19

JO - Sensors

JF - Sensors

SN - 1424-3210

IS - 3

M1 - 657

ER -