The influence of operating parameters on the drug release and anti-bacterial performances of alginate wound dressings prepared by three-dimensional plotting

Chih Wei Peng, Hsin Yi Lin, Hsin Wei Wang, Wei Wen Wu

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Three-dimensional plotting was used to manufacture fibrous alginate hydrogel wound dressings. Samples manufactured using varied operating parameters (increased air pressure, nozzle diameter, and layer increment or decreased calcium concentration, alginate concentration, and speed of the nozzle in the x and y directions) were compared to the control samples. The changes in the fiber size, porosity, tensile properties, degradation, swelling ratio, tetracycline release efficacy, water vapor transmission rate (WVTR), and bacterial inhibition potential due to alterations of the operating parameters were measured. The samples manufactured using altered operating parameters had larger fiber sizes and were less porous than the controls (p <0.05). A significantly higher Young's modulus, a larger ultimate tensile strength, less degradation, and lower swelling ratios were also found among some of the altered samples (p <0.05). The tetracycline release efficacies and bacterial inhibition potentials of the altered samples were not found to be significantly different from those of the controls. The WVTRs of most samples were slightly lower than those of common commercial dressings. When compared to films, the fibrous samples were able to absorb liquid faster and were less stiff, allowing for better conformation to the contours of the wounds. The fibrous samples also provided more sustained tetracycline release.

Original languageEnglish
Pages (from-to)2491-2500
Number of pages10
JournalMaterials Science and Engineering C
Volume32
Issue number8
DOIs
Publication statusPublished - Dec 1 2012

Fingerprint

plotting
Alginate
Tetracycline
drugs
Swelling
Nozzles
tetracyclines
Pharmaceutical Preparations
Degradation
Fibers
Hydrogel
Steam
Tensile properties
Hydrogels
Water vapor
Conformations
Calcium
Tensile strength
Porosity
Elastic moduli

Keywords

  • Alginate hydrogel
  • Antibiotic drug release
  • Bacterial inhibition
  • Porous scaffolds
  • Three dimensional plotting
  • Wound dressing

ASJC Scopus subject areas

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanical Engineering
  • Mechanics of Materials

Cite this

The influence of operating parameters on the drug release and anti-bacterial performances of alginate wound dressings prepared by three-dimensional plotting. / Peng, Chih Wei; Lin, Hsin Yi; Wang, Hsin Wei; Wu, Wei Wen.

In: Materials Science and Engineering C, Vol. 32, No. 8, 01.12.2012, p. 2491-2500.

Research output: Contribution to journalArticle

@article{f624a9247f9247028479a758c6c92d37,
title = "The influence of operating parameters on the drug release and anti-bacterial performances of alginate wound dressings prepared by three-dimensional plotting",
abstract = "Three-dimensional plotting was used to manufacture fibrous alginate hydrogel wound dressings. Samples manufactured using varied operating parameters (increased air pressure, nozzle diameter, and layer increment or decreased calcium concentration, alginate concentration, and speed of the nozzle in the x and y directions) were compared to the control samples. The changes in the fiber size, porosity, tensile properties, degradation, swelling ratio, tetracycline release efficacy, water vapor transmission rate (WVTR), and bacterial inhibition potential due to alterations of the operating parameters were measured. The samples manufactured using altered operating parameters had larger fiber sizes and were less porous than the controls (p <0.05). A significantly higher Young's modulus, a larger ultimate tensile strength, less degradation, and lower swelling ratios were also found among some of the altered samples (p <0.05). The tetracycline release efficacies and bacterial inhibition potentials of the altered samples were not found to be significantly different from those of the controls. The WVTRs of most samples were slightly lower than those of common commercial dressings. When compared to films, the fibrous samples were able to absorb liquid faster and were less stiff, allowing for better conformation to the contours of the wounds. The fibrous samples also provided more sustained tetracycline release.",
keywords = "Alginate hydrogel, Antibiotic drug release, Bacterial inhibition, Porous scaffolds, Three dimensional plotting, Wound dressing",
author = "Peng, {Chih Wei} and Lin, {Hsin Yi} and Wang, {Hsin Wei} and Wu, {Wei Wen}",
year = "2012",
month = "12",
day = "1",
doi = "10.1016/j.msec.2012.07.031",
language = "English",
volume = "32",
pages = "2491--2500",
journal = "Materials Science and Engineering C",
issn = "0928-4931",
publisher = "Elsevier BV",
number = "8",

}

TY - JOUR

T1 - The influence of operating parameters on the drug release and anti-bacterial performances of alginate wound dressings prepared by three-dimensional plotting

AU - Peng, Chih Wei

AU - Lin, Hsin Yi

AU - Wang, Hsin Wei

AU - Wu, Wei Wen

PY - 2012/12/1

Y1 - 2012/12/1

N2 - Three-dimensional plotting was used to manufacture fibrous alginate hydrogel wound dressings. Samples manufactured using varied operating parameters (increased air pressure, nozzle diameter, and layer increment or decreased calcium concentration, alginate concentration, and speed of the nozzle in the x and y directions) were compared to the control samples. The changes in the fiber size, porosity, tensile properties, degradation, swelling ratio, tetracycline release efficacy, water vapor transmission rate (WVTR), and bacterial inhibition potential due to alterations of the operating parameters were measured. The samples manufactured using altered operating parameters had larger fiber sizes and were less porous than the controls (p <0.05). A significantly higher Young's modulus, a larger ultimate tensile strength, less degradation, and lower swelling ratios were also found among some of the altered samples (p <0.05). The tetracycline release efficacies and bacterial inhibition potentials of the altered samples were not found to be significantly different from those of the controls. The WVTRs of most samples were slightly lower than those of common commercial dressings. When compared to films, the fibrous samples were able to absorb liquid faster and were less stiff, allowing for better conformation to the contours of the wounds. The fibrous samples also provided more sustained tetracycline release.

AB - Three-dimensional plotting was used to manufacture fibrous alginate hydrogel wound dressings. Samples manufactured using varied operating parameters (increased air pressure, nozzle diameter, and layer increment or decreased calcium concentration, alginate concentration, and speed of the nozzle in the x and y directions) were compared to the control samples. The changes in the fiber size, porosity, tensile properties, degradation, swelling ratio, tetracycline release efficacy, water vapor transmission rate (WVTR), and bacterial inhibition potential due to alterations of the operating parameters were measured. The samples manufactured using altered operating parameters had larger fiber sizes and were less porous than the controls (p <0.05). A significantly higher Young's modulus, a larger ultimate tensile strength, less degradation, and lower swelling ratios were also found among some of the altered samples (p <0.05). The tetracycline release efficacies and bacterial inhibition potentials of the altered samples were not found to be significantly different from those of the controls. The WVTRs of most samples were slightly lower than those of common commercial dressings. When compared to films, the fibrous samples were able to absorb liquid faster and were less stiff, allowing for better conformation to the contours of the wounds. The fibrous samples also provided more sustained tetracycline release.

KW - Alginate hydrogel

KW - Antibiotic drug release

KW - Bacterial inhibition

KW - Porous scaffolds

KW - Three dimensional plotting

KW - Wound dressing

UR - http://www.scopus.com/inward/record.url?scp=84866040266&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866040266&partnerID=8YFLogxK

U2 - 10.1016/j.msec.2012.07.031

DO - 10.1016/j.msec.2012.07.031

M3 - Article

AN - SCOPUS:84866040266

VL - 32

SP - 2491

EP - 2500

JO - Materials Science and Engineering C

JF - Materials Science and Engineering C

SN - 0928-4931

IS - 8

ER -