Stoppa operation for complex recurrent groin hernia

A ten-year experience

C. S. Huang, J. S. Liu, S. H. Tu

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Repairs for complex recurrent hernia are associated with a high re-recurrence rate. To terminate this vicious cycle, a radical procedure such as Stoppa operation may be indicated, however, the safety and long-term effectiveness of this procedure for complex recurrences have not been demonstrated in Taiwanese patients. Demographic, preoperative, operative and yearly follow-up data were analyzed for 135 patients who were treated from 1988 to 1998 for complex recurrent groin hernias using Stoppa operation with modification. Preperitoneal exploration of the 176 sides of recurrence revealed direct recurrences (64%), indirect (32%) and femoral (3%) recurrences. Thirty percent of them had multiple defects. The average size of mesh used was 23±2 cm × 14.6±1.5 cm for bilateral and 10.2±1.9 cm × 12.2±2.3 cm for unilateral recurrences. A 2 cm reduction from the transverse dimension of mesh prothesis compared with the original Stoppa proctocol was found to be better for Taiwanese patients. Surgical complication rate was 10%, including acute myocardial infarction (1), scrotal hematoma(9), low abdominal discomfort (2) and peritoneal defects over the mesh (1). During follow-up of a mean duration of 5.5 years (range one to 11 years) with a 87% follow-up rate, re-recurrences were identified in two (2%). The results of this study demonstrate that Stoppa operation with our modification in mesh design provides very effective and safe treatment for complex recurrent groin hernias in Taiwanese.

Original languageEnglish
Pages (from-to)178-184
Number of pages7
JournalFormosan Journal of Surgery
Volume34
Issue number4
Publication statusPublished - 2001
Externally publishedYes

Fingerprint

Groin
Hernia
Recurrence
Thigh
Hematoma
Myocardial Infarction
Demography
Safety

Keywords

  • Complex recurrences
  • Groin hernia
  • Recurrent hernia
  • Stoppa operation

ASJC Scopus subject areas

  • Surgery

Cite this

Stoppa operation for complex recurrent groin hernia : A ten-year experience. / Huang, C. S.; Liu, J. S.; Tu, S. H.

In: Formosan Journal of Surgery, Vol. 34, No. 4, 2001, p. 178-184.

Research output: Contribution to journalArticle

@article{fd3ded4d5d5e45f9bd019edb3ec985bf,
title = "Stoppa operation for complex recurrent groin hernia: A ten-year experience",
abstract = "Repairs for complex recurrent hernia are associated with a high re-recurrence rate. To terminate this vicious cycle, a radical procedure such as Stoppa operation may be indicated, however, the safety and long-term effectiveness of this procedure for complex recurrences have not been demonstrated in Taiwanese patients. Demographic, preoperative, operative and yearly follow-up data were analyzed for 135 patients who were treated from 1988 to 1998 for complex recurrent groin hernias using Stoppa operation with modification. Preperitoneal exploration of the 176 sides of recurrence revealed direct recurrences (64{\%}), indirect (32{\%}) and femoral (3{\%}) recurrences. Thirty percent of them had multiple defects. The average size of mesh used was 23±2 cm × 14.6±1.5 cm for bilateral and 10.2±1.9 cm × 12.2±2.3 cm for unilateral recurrences. A 2 cm reduction from the transverse dimension of mesh prothesis compared with the original Stoppa proctocol was found to be better for Taiwanese patients. Surgical complication rate was 10{\%}, including acute myocardial infarction (1), scrotal hematoma(9), low abdominal discomfort (2) and peritoneal defects over the mesh (1). During follow-up of a mean duration of 5.5 years (range one to 11 years) with a 87{\%} follow-up rate, re-recurrences were identified in two (2{\%}). The results of this study demonstrate that Stoppa operation with our modification in mesh design provides very effective and safe treatment for complex recurrent groin hernias in Taiwanese.",
keywords = "Complex recurrences, Groin hernia, Recurrent hernia, Stoppa operation",
author = "Huang, {C. S.} and Liu, {J. S.} and Tu, {S. H.}",
year = "2001",
language = "English",
volume = "34",
pages = "178--184",
journal = "Formosan Journal of Surgery",
issn = "1011-6788",
publisher = "臺灣外科醫學會",
number = "4",

}

TY - JOUR

T1 - Stoppa operation for complex recurrent groin hernia

T2 - A ten-year experience

AU - Huang, C. S.

AU - Liu, J. S.

AU - Tu, S. H.

PY - 2001

Y1 - 2001

N2 - Repairs for complex recurrent hernia are associated with a high re-recurrence rate. To terminate this vicious cycle, a radical procedure such as Stoppa operation may be indicated, however, the safety and long-term effectiveness of this procedure for complex recurrences have not been demonstrated in Taiwanese patients. Demographic, preoperative, operative and yearly follow-up data were analyzed for 135 patients who were treated from 1988 to 1998 for complex recurrent groin hernias using Stoppa operation with modification. Preperitoneal exploration of the 176 sides of recurrence revealed direct recurrences (64%), indirect (32%) and femoral (3%) recurrences. Thirty percent of them had multiple defects. The average size of mesh used was 23±2 cm × 14.6±1.5 cm for bilateral and 10.2±1.9 cm × 12.2±2.3 cm for unilateral recurrences. A 2 cm reduction from the transverse dimension of mesh prothesis compared with the original Stoppa proctocol was found to be better for Taiwanese patients. Surgical complication rate was 10%, including acute myocardial infarction (1), scrotal hematoma(9), low abdominal discomfort (2) and peritoneal defects over the mesh (1). During follow-up of a mean duration of 5.5 years (range one to 11 years) with a 87% follow-up rate, re-recurrences were identified in two (2%). The results of this study demonstrate that Stoppa operation with our modification in mesh design provides very effective and safe treatment for complex recurrent groin hernias in Taiwanese.

AB - Repairs for complex recurrent hernia are associated with a high re-recurrence rate. To terminate this vicious cycle, a radical procedure such as Stoppa operation may be indicated, however, the safety and long-term effectiveness of this procedure for complex recurrences have not been demonstrated in Taiwanese patients. Demographic, preoperative, operative and yearly follow-up data were analyzed for 135 patients who were treated from 1988 to 1998 for complex recurrent groin hernias using Stoppa operation with modification. Preperitoneal exploration of the 176 sides of recurrence revealed direct recurrences (64%), indirect (32%) and femoral (3%) recurrences. Thirty percent of them had multiple defects. The average size of mesh used was 23±2 cm × 14.6±1.5 cm for bilateral and 10.2±1.9 cm × 12.2±2.3 cm for unilateral recurrences. A 2 cm reduction from the transverse dimension of mesh prothesis compared with the original Stoppa proctocol was found to be better for Taiwanese patients. Surgical complication rate was 10%, including acute myocardial infarction (1), scrotal hematoma(9), low abdominal discomfort (2) and peritoneal defects over the mesh (1). During follow-up of a mean duration of 5.5 years (range one to 11 years) with a 87% follow-up rate, re-recurrences were identified in two (2%). The results of this study demonstrate that Stoppa operation with our modification in mesh design provides very effective and safe treatment for complex recurrent groin hernias in Taiwanese.

KW - Complex recurrences

KW - Groin hernia

KW - Recurrent hernia

KW - Stoppa operation

UR - http://www.scopus.com/inward/record.url?scp=0034861102&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034861102&partnerID=8YFLogxK

M3 - Article

VL - 34

SP - 178

EP - 184

JO - Formosan Journal of Surgery

JF - Formosan Journal of Surgery

SN - 1011-6788

IS - 4

ER -