Objective: Stent graft-induced new entry (SINE) has been increasingly observed after thoracic endovascular aortic repair (TEVAR) for aortic dissection. We investigated the mechanism of late distal SINE, prevention strategies, proper size selection of the stent graft, and implantation sequence. Methods: From November 2006 to May 2011, 99 patients with aortic dissection underwent TEVAR with Zenith TX2 stent grafts (Cook, Bloomington, Ind) at our center. Among them, 27 distal SINEs were recognized. Eight of these patients with complicated distal SINE required intervention with new distal endografts, and all were enrolled for further analysis. Results: Eight of the 27 patients with distal SINE underwent a secondary endograft procedure from February 2011 to July 2011. All were successfully treated without any complications or deaths. A high taper ratio (35% ± 11%) and excessive oversizing of the true lumen area at the distal stent level (293% ± 76%) were noted among these patients. Conclusions: The incidence of distal SINE seemed to be high; however, there were also low rates of death and complications after TEVAR for aortic dissection using stainless steel-based stent grafts. Complicated distal SINE can successfully be resolved by distal endograft implantation. Excessive oversizing of the distal stent graft, as measured by the true lumen area, may be a significant factor causing delayed distal SINE. Precise size selection is crucial for the distal end of the stent, especially for high taper ratio dissection pathology in which the implantation sequence of a distal small-sized stent graft first might be considered to prevent future distal SINE.

Original languageEnglish
Pages (from-to)64-71
Number of pages8
JournalJournal of Vascular Surgery
Volume57
Issue number1
DOIs
Publication statusPublished - Jan 1 2013
Externally publishedYes

Fingerprint

Stainless Steel
Stents
Dissection
Transplants
Equipment and Supplies
Thorax
Short Interspersed Nucleotide Elements

ASJC Scopus subject areas

  • Surgery
  • Cardiology and Cardiovascular Medicine

Cite this

Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection. / Weng, Shih Hsien; Weng, Chi Feng; Chen, Wei Yuan; Huang, Chun Yang; Chen, I. Ming; Chen, Chun Ku; Hsu, Chiao Po; Shih, Chun Che.

In: Journal of Vascular Surgery, Vol. 57, No. 1, 01.01.2013, p. 64-71.

Research output: Contribution to journalArticle

Weng, Shih Hsien ; Weng, Chi Feng ; Chen, Wei Yuan ; Huang, Chun Yang ; Chen, I. Ming ; Chen, Chun Ku ; Hsu, Chiao Po ; Shih, Chun Che. / Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection. In: Journal of Vascular Surgery. 2013 ; Vol. 57, No. 1. pp. 64-71.
@article{9779a15338e54abd9b5ad58fac277711,
title = "Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection",
abstract = "Objective: Stent graft-induced new entry (SINE) has been increasingly observed after thoracic endovascular aortic repair (TEVAR) for aortic dissection. We investigated the mechanism of late distal SINE, prevention strategies, proper size selection of the stent graft, and implantation sequence. Methods: From November 2006 to May 2011, 99 patients with aortic dissection underwent TEVAR with Zenith TX2 stent grafts (Cook, Bloomington, Ind) at our center. Among them, 27 distal SINEs were recognized. Eight of these patients with complicated distal SINE required intervention with new distal endografts, and all were enrolled for further analysis. Results: Eight of the 27 patients with distal SINE underwent a secondary endograft procedure from February 2011 to July 2011. All were successfully treated without any complications or deaths. A high taper ratio (35{\%} ± 11{\%}) and excessive oversizing of the true lumen area at the distal stent level (293{\%} ± 76{\%}) were noted among these patients. Conclusions: The incidence of distal SINE seemed to be high; however, there were also low rates of death and complications after TEVAR for aortic dissection using stainless steel-based stent grafts. Complicated distal SINE can successfully be resolved by distal endograft implantation. Excessive oversizing of the distal stent graft, as measured by the true lumen area, may be a significant factor causing delayed distal SINE. Precise size selection is crucial for the distal end of the stent, especially for high taper ratio dissection pathology in which the implantation sequence of a distal small-sized stent graft first might be considered to prevent future distal SINE.",
author = "Weng, {Shih Hsien} and Weng, {Chi Feng} and Chen, {Wei Yuan} and Huang, {Chun Yang} and Chen, {I. Ming} and Chen, {Chun Ku} and Hsu, {Chiao Po} and Shih, {Chun Che}",
year = "2013",
month = "1",
day = "1",
doi = "10.1016/j.jvs.2012.07.006",
language = "English",
volume = "57",
pages = "64--71",
journal = "Journal of Vascular Surgery",
issn = "0741-5214",
publisher = "Mosby Inc.",
number = "1",

}

TY - JOUR

T1 - Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection

AU - Weng, Shih Hsien

AU - Weng, Chi Feng

AU - Chen, Wei Yuan

AU - Huang, Chun Yang

AU - Chen, I. Ming

AU - Chen, Chun Ku

AU - Hsu, Chiao Po

AU - Shih, Chun Che

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Objective: Stent graft-induced new entry (SINE) has been increasingly observed after thoracic endovascular aortic repair (TEVAR) for aortic dissection. We investigated the mechanism of late distal SINE, prevention strategies, proper size selection of the stent graft, and implantation sequence. Methods: From November 2006 to May 2011, 99 patients with aortic dissection underwent TEVAR with Zenith TX2 stent grafts (Cook, Bloomington, Ind) at our center. Among them, 27 distal SINEs were recognized. Eight of these patients with complicated distal SINE required intervention with new distal endografts, and all were enrolled for further analysis. Results: Eight of the 27 patients with distal SINE underwent a secondary endograft procedure from February 2011 to July 2011. All were successfully treated without any complications or deaths. A high taper ratio (35% ± 11%) and excessive oversizing of the true lumen area at the distal stent level (293% ± 76%) were noted among these patients. Conclusions: The incidence of distal SINE seemed to be high; however, there were also low rates of death and complications after TEVAR for aortic dissection using stainless steel-based stent grafts. Complicated distal SINE can successfully be resolved by distal endograft implantation. Excessive oversizing of the distal stent graft, as measured by the true lumen area, may be a significant factor causing delayed distal SINE. Precise size selection is crucial for the distal end of the stent, especially for high taper ratio dissection pathology in which the implantation sequence of a distal small-sized stent graft first might be considered to prevent future distal SINE.

AB - Objective: Stent graft-induced new entry (SINE) has been increasingly observed after thoracic endovascular aortic repair (TEVAR) for aortic dissection. We investigated the mechanism of late distal SINE, prevention strategies, proper size selection of the stent graft, and implantation sequence. Methods: From November 2006 to May 2011, 99 patients with aortic dissection underwent TEVAR with Zenith TX2 stent grafts (Cook, Bloomington, Ind) at our center. Among them, 27 distal SINEs were recognized. Eight of these patients with complicated distal SINE required intervention with new distal endografts, and all were enrolled for further analysis. Results: Eight of the 27 patients with distal SINE underwent a secondary endograft procedure from February 2011 to July 2011. All were successfully treated without any complications or deaths. A high taper ratio (35% ± 11%) and excessive oversizing of the true lumen area at the distal stent level (293% ± 76%) were noted among these patients. Conclusions: The incidence of distal SINE seemed to be high; however, there were also low rates of death and complications after TEVAR for aortic dissection using stainless steel-based stent grafts. Complicated distal SINE can successfully be resolved by distal endograft implantation. Excessive oversizing of the distal stent graft, as measured by the true lumen area, may be a significant factor causing delayed distal SINE. Precise size selection is crucial for the distal end of the stent, especially for high taper ratio dissection pathology in which the implantation sequence of a distal small-sized stent graft first might be considered to prevent future distal SINE.

UR - http://www.scopus.com/inward/record.url?scp=84871612909&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84871612909&partnerID=8YFLogxK

U2 - 10.1016/j.jvs.2012.07.006

DO - 10.1016/j.jvs.2012.07.006

M3 - Article

C2 - 23141675

AN - SCOPUS:84871612909

VL - 57

SP - 64

EP - 71

JO - Journal of Vascular Surgery

JF - Journal of Vascular Surgery

SN - 0741-5214

IS - 1

ER -