Beta 1 integrin is a membrane protein responsible for attachment and migration of osteosarcoma cells. In this study, expression of β1 integrin on MG-63 cells, a human osteogenic sarcoma cell line, was monitored using electrochemical impedance spectroscopy (EIS). ITO-based biochips were developed using a semiconductor technique. Differences in electric resistance (ΔR) were measured continuously when cells binding with anti-β1 integrin antibody coagulated with nano-scale gold particles. The results of the EIS system were compared with traditional immunofluorescence staining. We found that sample chambers with higher cell densities had larger ΔR values. When the cell densities increased from 5×10 4 cells/ml to 5×10 5 cells/ml, the ΔR value dose-dependently increased from 14Ω to 37Ω. In addition, a highly linear relationship (correlation coefficient, 0.921) was found between the ΔR values and the corresponding fluorescence intensities (p

Original languageEnglish
Pages (from-to)221-226
Number of pages6
JournalBiosensors and Bioelectronics
Volume28
Issue number1
DOIs
Publication statusPublished - Oct 15 2011

Fingerprint

Dielectric Spectroscopy
Electrochemical impedance spectroscopy
Integrins
Biochips
Osteosarcoma
Antibodies
Cell Count
Gold
Fluorescence
Cells
Semiconductor materials
Integrin beta Chains
Proteins
Membranes
Semiconductors
Membrane Proteins
Electric Impedance
Cell Movement
Fluorescent Antibody Technique
Staining and Labeling

Keywords

  • Electrochemical impedance spectroscopy
  • Immunosensor
  • Integrin
  • ITO
  • MG-63

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering
  • Biotechnology
  • Electrochemistry

Cite this

Real-time detection of β1 integrin expression on MG-63 cells using electrochemical impedance spectroscopy. / Lin, Chun Yen; Teng, Nai Chia; Hsieh, Sung Chih; Lin, Yung Sheng; Chang, Wei Jen; Hsiao, Sheng Yi; Huang, Hui Shun; Huang, Haw Ming.

In: Biosensors and Bioelectronics, Vol. 28, No. 1, 15.10.2011, p. 221-226.

Research output: Contribution to journalArticle

@article{2b0295582d9e459395e75ba3ec6c593e,
title = "Real-time detection of β1 integrin expression on MG-63 cells using electrochemical impedance spectroscopy",
abstract = "Beta 1 integrin is a membrane protein responsible for attachment and migration of osteosarcoma cells. In this study, expression of β1 integrin on MG-63 cells, a human osteogenic sarcoma cell line, was monitored using electrochemical impedance spectroscopy (EIS). ITO-based biochips were developed using a semiconductor technique. Differences in electric resistance (ΔR) were measured continuously when cells binding with anti-β1 integrin antibody coagulated with nano-scale gold particles. The results of the EIS system were compared with traditional immunofluorescence staining. We found that sample chambers with higher cell densities had larger ΔR values. When the cell densities increased from 5×10 4 cells/ml to 5×10 5 cells/ml, the ΔR value dose-dependently increased from 14Ω to 37Ω. In addition, a highly linear relationship (correlation coefficient, 0.921) was found between the ΔR values and the corresponding fluorescence intensities (p",
keywords = "Electrochemical impedance spectroscopy, Immunosensor, Integrin, ITO, MG-63",
author = "Lin, {Chun Yen} and Teng, {Nai Chia} and Hsieh, {Sung Chih} and Lin, {Yung Sheng} and Chang, {Wei Jen} and Hsiao, {Sheng Yi} and Huang, {Hui Shun} and Huang, {Haw Ming}",
year = "2011",
month = "10",
day = "15",
doi = "10.1016/j.bios.2011.07.022",
language = "English",
volume = "28",
pages = "221--226",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "1",

}

TY - JOUR

T1 - Real-time detection of β1 integrin expression on MG-63 cells using electrochemical impedance spectroscopy

AU - Lin, Chun Yen

AU - Teng, Nai Chia

AU - Hsieh, Sung Chih

AU - Lin, Yung Sheng

AU - Chang, Wei Jen

AU - Hsiao, Sheng Yi

AU - Huang, Hui Shun

AU - Huang, Haw Ming

PY - 2011/10/15

Y1 - 2011/10/15

N2 - Beta 1 integrin is a membrane protein responsible for attachment and migration of osteosarcoma cells. In this study, expression of β1 integrin on MG-63 cells, a human osteogenic sarcoma cell line, was monitored using electrochemical impedance spectroscopy (EIS). ITO-based biochips were developed using a semiconductor technique. Differences in electric resistance (ΔR) were measured continuously when cells binding with anti-β1 integrin antibody coagulated with nano-scale gold particles. The results of the EIS system were compared with traditional immunofluorescence staining. We found that sample chambers with higher cell densities had larger ΔR values. When the cell densities increased from 5×10 4 cells/ml to 5×10 5 cells/ml, the ΔR value dose-dependently increased from 14Ω to 37Ω. In addition, a highly linear relationship (correlation coefficient, 0.921) was found between the ΔR values and the corresponding fluorescence intensities (p

AB - Beta 1 integrin is a membrane protein responsible for attachment and migration of osteosarcoma cells. In this study, expression of β1 integrin on MG-63 cells, a human osteogenic sarcoma cell line, was monitored using electrochemical impedance spectroscopy (EIS). ITO-based biochips were developed using a semiconductor technique. Differences in electric resistance (ΔR) were measured continuously when cells binding with anti-β1 integrin antibody coagulated with nano-scale gold particles. The results of the EIS system were compared with traditional immunofluorescence staining. We found that sample chambers with higher cell densities had larger ΔR values. When the cell densities increased from 5×10 4 cells/ml to 5×10 5 cells/ml, the ΔR value dose-dependently increased from 14Ω to 37Ω. In addition, a highly linear relationship (correlation coefficient, 0.921) was found between the ΔR values and the corresponding fluorescence intensities (p

KW - Electrochemical impedance spectroscopy

KW - Immunosensor

KW - Integrin

KW - ITO

KW - MG-63

UR - http://www.scopus.com/inward/record.url?scp=80052362563&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052362563&partnerID=8YFLogxK

U2 - 10.1016/j.bios.2011.07.022

DO - 10.1016/j.bios.2011.07.022

M3 - Article

C2 - 21816605

AN - SCOPUS:80052362563

VL - 28

SP - 221

EP - 226

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 1

ER -