Quantitation and method validation for the determination of flurbiprofen by high performance liquid chromatography

Chiwei Lo, Yibo Liou, Yiehiun You, An-Bang Wu

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Flurbiprofen (FB) is one of photosensitizing non-steroidal anti-inflammatory drugs (NSAIDs). When FB was irradiated by low pressure mercury lamp in methanol, 3 photoproducts could be observed, respectively. A sensitive, and accurate stability-indicating high performance liquid chromatography for determining the photodegradation of FB was developed and validated with linear regression of calibration curve, intra-day test, inter-day test. The RSDs of intra-day and inter-day tests were lower than 1.1% and 1.7%, respectively. The percent recovery was between 98.2% and 102. 0%. These results show that good selectivity and specificity can be obtained by our established high performance liquid chromatographic method. With different alcoholic solvents, photo-kinetic of FB was observed. In the experiment, the results of using three alcoholic solvents were presented non-significant difference.

Original languageEnglish
Pages (from-to)1327-1330
Number of pages4
JournalFenxi Huaxue
Volume34
Issue number9
Publication statusPublished - Sep 2006

Fingerprint

Flurbiprofen
High performance liquid chromatography
Mercury vapor lamps
Photodegradation
Linear regression
Methanol
Anti-Inflammatory Agents
Calibration
Recovery
Kinetics
Liquids
Pharmaceutical Preparations
Experiments

Keywords

  • Flurbiprofen
  • High performance liquid chromatography
  • Photo-kinetic
  • Photodegradation

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Quantitation and method validation for the determination of flurbiprofen by high performance liquid chromatography. / Lo, Chiwei; Liou, Yibo; You, Yiehiun; Wu, An-Bang.

In: Fenxi Huaxue, Vol. 34, No. 9, 09.2006, p. 1327-1330.

Research output: Contribution to journalArticle

Lo, Chiwei ; Liou, Yibo ; You, Yiehiun ; Wu, An-Bang. / Quantitation and method validation for the determination of flurbiprofen by high performance liquid chromatography. In: Fenxi Huaxue. 2006 ; Vol. 34, No. 9. pp. 1327-1330.
@article{2a2685c1ea1f4672a716b9c1123983e6,
title = "Quantitation and method validation for the determination of flurbiprofen by high performance liquid chromatography",
abstract = "Flurbiprofen (FB) is one of photosensitizing non-steroidal anti-inflammatory drugs (NSAIDs). When FB was irradiated by low pressure mercury lamp in methanol, 3 photoproducts could be observed, respectively. A sensitive, and accurate stability-indicating high performance liquid chromatography for determining the photodegradation of FB was developed and validated with linear regression of calibration curve, intra-day test, inter-day test. The RSDs of intra-day and inter-day tests were lower than 1.1{\%} and 1.7{\%}, respectively. The percent recovery was between 98.2{\%} and 102. 0{\%}. These results show that good selectivity and specificity can be obtained by our established high performance liquid chromatographic method. With different alcoholic solvents, photo-kinetic of FB was observed. In the experiment, the results of using three alcoholic solvents were presented non-significant difference.",
keywords = "Flurbiprofen, High performance liquid chromatography, Photo-kinetic, Photodegradation",
author = "Chiwei Lo and Yibo Liou and Yiehiun You and An-Bang Wu",
year = "2006",
month = "9",
language = "English",
volume = "34",
pages = "1327--1330",
journal = "Fenxi Huaxue",
issn = "0253-3820",
publisher = "Chinese Academy of Sciences",
number = "9",

}

TY - JOUR

T1 - Quantitation and method validation for the determination of flurbiprofen by high performance liquid chromatography

AU - Lo, Chiwei

AU - Liou, Yibo

AU - You, Yiehiun

AU - Wu, An-Bang

PY - 2006/9

Y1 - 2006/9

N2 - Flurbiprofen (FB) is one of photosensitizing non-steroidal anti-inflammatory drugs (NSAIDs). When FB was irradiated by low pressure mercury lamp in methanol, 3 photoproducts could be observed, respectively. A sensitive, and accurate stability-indicating high performance liquid chromatography for determining the photodegradation of FB was developed and validated with linear regression of calibration curve, intra-day test, inter-day test. The RSDs of intra-day and inter-day tests were lower than 1.1% and 1.7%, respectively. The percent recovery was between 98.2% and 102. 0%. These results show that good selectivity and specificity can be obtained by our established high performance liquid chromatographic method. With different alcoholic solvents, photo-kinetic of FB was observed. In the experiment, the results of using three alcoholic solvents were presented non-significant difference.

AB - Flurbiprofen (FB) is one of photosensitizing non-steroidal anti-inflammatory drugs (NSAIDs). When FB was irradiated by low pressure mercury lamp in methanol, 3 photoproducts could be observed, respectively. A sensitive, and accurate stability-indicating high performance liquid chromatography for determining the photodegradation of FB was developed and validated with linear regression of calibration curve, intra-day test, inter-day test. The RSDs of intra-day and inter-day tests were lower than 1.1% and 1.7%, respectively. The percent recovery was between 98.2% and 102. 0%. These results show that good selectivity and specificity can be obtained by our established high performance liquid chromatographic method. With different alcoholic solvents, photo-kinetic of FB was observed. In the experiment, the results of using three alcoholic solvents were presented non-significant difference.

KW - Flurbiprofen

KW - High performance liquid chromatography

KW - Photo-kinetic

KW - Photodegradation

UR - http://www.scopus.com/inward/record.url?scp=67650550488&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67650550488&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:67650550488

VL - 34

SP - 1327

EP - 1330

JO - Fenxi Huaxue

JF - Fenxi Huaxue

SN - 0253-3820

IS - 9

ER -