Abstract

Traumatic brain injury (TBI) typically causes permanent brain tissue damage, which leads to permanent severe voiding dysfunction. Urinary retention is often refractory to standard therapies, and most patients require self-catheterization, which results in frequent urinary tract infections and reduces quality of life. Deep brain stimulation (DBS) might be a feasible alternative approach for treating bladder disorders in patients with TBI. In this study, we developed a DBS system with a closed-loop control strategy and determined the feasibility of this DBS system for improving bladder voiding function in a TBI animal model. A prototype of the DBS system was designed, fabricated and integrated with a closed-loop control algorithm based on the real-time external urethral sphincter-electromyogram feedback. A series of animal experiments was conducted to determine whether the feedback algorithm accurately detects the bladder status during cystometric measurements. Subsequent animal experiments were conducted to implement this DBS system and determine the performance of the closed-loop strategy for improving bladder functions in the TBI animal model. We successfully implemented a closed-loop algorithm for DBS control, and the accuracy of the bladder voiding phase detection was > 90%. Our system significantly improved the voiding efficiency in TBI rats from 22 to 74%. Although the prototype of the DBS feedback system was fabricated with surface-mounted device components and mounted on a 3D printed circuit board, the design principles and animal experience gathered from this research can serve as a basis for developing a new implantable bladder controller in the future.

Original languageEnglish
Pages (from-to)337-349
Number of pages13
JournalJournal of Medical and Biological Engineering
Volume38
Issue number3
DOIs
Publication statusPublished - Jun 1 2018

Fingerprint

Feedback control
Brain
Animals
Feedback
Surface mount technology
Printed circuit boards
Refractory materials
Rats
Experiments
Tissue
Controllers

Keywords

  • Closed-loop
  • Deep brain stimulation
  • Electromyogram
  • Traumatic brain injury
  • Urinary retention

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Prototype Deep Brain Stimulation System with Closed-Loop Control Feedback for Modulating Bladder Functions in Traumatic Brain Injured Animals. / Jen, En; Lin, Chii Wann; Hsieh, Tsung Hsun; Chiu, Yi Chun; Lu, Tsung Che; Chen, Shih Ching; Chen, Meng Chao; Peng, Chih Wei.

In: Journal of Medical and Biological Engineering, Vol. 38, No. 3, 01.06.2018, p. 337-349.

Research output: Contribution to journalArticle

@article{8ab399ec653b421cb7506270d7545b70,
title = "Prototype Deep Brain Stimulation System with Closed-Loop Control Feedback for Modulating Bladder Functions in Traumatic Brain Injured Animals",
abstract = "Traumatic brain injury (TBI) typically causes permanent brain tissue damage, which leads to permanent severe voiding dysfunction. Urinary retention is often refractory to standard therapies, and most patients require self-catheterization, which results in frequent urinary tract infections and reduces quality of life. Deep brain stimulation (DBS) might be a feasible alternative approach for treating bladder disorders in patients with TBI. In this study, we developed a DBS system with a closed-loop control strategy and determined the feasibility of this DBS system for improving bladder voiding function in a TBI animal model. A prototype of the DBS system was designed, fabricated and integrated with a closed-loop control algorithm based on the real-time external urethral sphincter-electromyogram feedback. A series of animal experiments was conducted to determine whether the feedback algorithm accurately detects the bladder status during cystometric measurements. Subsequent animal experiments were conducted to implement this DBS system and determine the performance of the closed-loop strategy for improving bladder functions in the TBI animal model. We successfully implemented a closed-loop algorithm for DBS control, and the accuracy of the bladder voiding phase detection was > 90{\%}. Our system significantly improved the voiding efficiency in TBI rats from 22 to 74{\%}. Although the prototype of the DBS feedback system was fabricated with surface-mounted device components and mounted on a 3D printed circuit board, the design principles and animal experience gathered from this research can serve as a basis for developing a new implantable bladder controller in the future.",
keywords = "Closed-loop, Deep brain stimulation, Electromyogram, Traumatic brain injury, Urinary retention",
author = "En Jen and Lin, {Chii Wann} and Hsieh, {Tsung Hsun} and Chiu, {Yi Chun} and Lu, {Tsung Che} and Chen, {Shih Ching} and Chen, {Meng Chao} and Peng, {Chih Wei}",
year = "2018",
month = "6",
day = "1",
doi = "10.1007/s40846-017-0326-1",
language = "English",
volume = "38",
pages = "337--349",
journal = "Journal of Medical and Biological Engineering",
issn = "1609-0985",
publisher = "中華民國生物醫學工程學會",
number = "3",

}

TY - JOUR

T1 - Prototype Deep Brain Stimulation System with Closed-Loop Control Feedback for Modulating Bladder Functions in Traumatic Brain Injured Animals

AU - Jen, En

AU - Lin, Chii Wann

AU - Hsieh, Tsung Hsun

AU - Chiu, Yi Chun

AU - Lu, Tsung Che

AU - Chen, Shih Ching

AU - Chen, Meng Chao

AU - Peng, Chih Wei

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Traumatic brain injury (TBI) typically causes permanent brain tissue damage, which leads to permanent severe voiding dysfunction. Urinary retention is often refractory to standard therapies, and most patients require self-catheterization, which results in frequent urinary tract infections and reduces quality of life. Deep brain stimulation (DBS) might be a feasible alternative approach for treating bladder disorders in patients with TBI. In this study, we developed a DBS system with a closed-loop control strategy and determined the feasibility of this DBS system for improving bladder voiding function in a TBI animal model. A prototype of the DBS system was designed, fabricated and integrated with a closed-loop control algorithm based on the real-time external urethral sphincter-electromyogram feedback. A series of animal experiments was conducted to determine whether the feedback algorithm accurately detects the bladder status during cystometric measurements. Subsequent animal experiments were conducted to implement this DBS system and determine the performance of the closed-loop strategy for improving bladder functions in the TBI animal model. We successfully implemented a closed-loop algorithm for DBS control, and the accuracy of the bladder voiding phase detection was > 90%. Our system significantly improved the voiding efficiency in TBI rats from 22 to 74%. Although the prototype of the DBS feedback system was fabricated with surface-mounted device components and mounted on a 3D printed circuit board, the design principles and animal experience gathered from this research can serve as a basis for developing a new implantable bladder controller in the future.

AB - Traumatic brain injury (TBI) typically causes permanent brain tissue damage, which leads to permanent severe voiding dysfunction. Urinary retention is often refractory to standard therapies, and most patients require self-catheterization, which results in frequent urinary tract infections and reduces quality of life. Deep brain stimulation (DBS) might be a feasible alternative approach for treating bladder disorders in patients with TBI. In this study, we developed a DBS system with a closed-loop control strategy and determined the feasibility of this DBS system for improving bladder voiding function in a TBI animal model. A prototype of the DBS system was designed, fabricated and integrated with a closed-loop control algorithm based on the real-time external urethral sphincter-electromyogram feedback. A series of animal experiments was conducted to determine whether the feedback algorithm accurately detects the bladder status during cystometric measurements. Subsequent animal experiments were conducted to implement this DBS system and determine the performance of the closed-loop strategy for improving bladder functions in the TBI animal model. We successfully implemented a closed-loop algorithm for DBS control, and the accuracy of the bladder voiding phase detection was > 90%. Our system significantly improved the voiding efficiency in TBI rats from 22 to 74%. Although the prototype of the DBS feedback system was fabricated with surface-mounted device components and mounted on a 3D printed circuit board, the design principles and animal experience gathered from this research can serve as a basis for developing a new implantable bladder controller in the future.

KW - Closed-loop

KW - Deep brain stimulation

KW - Electromyogram

KW - Traumatic brain injury

KW - Urinary retention

UR - http://www.scopus.com/inward/record.url?scp=85047264341&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85047264341&partnerID=8YFLogxK

U2 - 10.1007/s40846-017-0326-1

DO - 10.1007/s40846-017-0326-1

M3 - Article

VL - 38

SP - 337

EP - 349

JO - Journal of Medical and Biological Engineering

JF - Journal of Medical and Biological Engineering

SN - 1609-0985

IS - 3

ER -