Porous polyethylene implants in orbital floor reconstruction

I. Chan Lin, Shu Lang Liao, L. L K Lin

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

Background/Purpose: Various alloplastic materials are used in orbital wall reconstruction. This study investigated the outcome of patients treated with porous polyethylene sheet implants in the reconstruction of orbital floor fracture. Methods: Twenty-one patients who underwent orbital reconstructions using 0.85-mm porous polyethylene sheets for the repair of orbital floor fracture were included. A transconjunctival approach was used in all patients. The mean duration of postoperative follow-up was 29.7±12.3 months. Postoperatively, results and complications such as infection and implant extrusion were followed-up on the first day, the first week, monthly for the first 3 months and then every 3-6 months thereafter. Results: All 21 patients had symptomatic diplopia before surgery. The diplopia resolved in 14 patients and improved in seven patients within the first month after surgery. All patients except one were free from diplopia at follow-up periods exceeding 6 months. Preoperative enophthalmos resolved in four of seven patients and improved in three. None of the patients developed orbital infection, implant exposure or migration, worsening diplopia, infraorbital anesthesia or loss of vision during follow-up. Conclusion: The study demonstrated that porous polyethylene implants in the repair of orbital wall fractures had good results with few complications.

Original languageEnglish
Pages (from-to)51-57
Number of pages7
JournalJournal of the Formosan Medical Association = Taiwan yi zhi
Volume106
Issue number1
Publication statusPublished - Jan 2007
Externally publishedYes

Fingerprint

Orbital Implants
Polyethylene
Diplopia
Orbital Fractures
Enophthalmos
Infection
Anesthesia
Outcome Assessment (Health Care)

Keywords

  • Blowout fracture
  • Orbital implant
  • Porous polyethylene

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Porous polyethylene implants in orbital floor reconstruction. / Lin, I. Chan; Liao, Shu Lang; Lin, L. L K.

In: Journal of the Formosan Medical Association = Taiwan yi zhi, Vol. 106, No. 1, 01.2007, p. 51-57.

Research output: Contribution to journalArticle

@article{62d3bb20068944bf9b4fe0f494d475ea,
title = "Porous polyethylene implants in orbital floor reconstruction",
abstract = "Background/Purpose: Various alloplastic materials are used in orbital wall reconstruction. This study investigated the outcome of patients treated with porous polyethylene sheet implants in the reconstruction of orbital floor fracture. Methods: Twenty-one patients who underwent orbital reconstructions using 0.85-mm porous polyethylene sheets for the repair of orbital floor fracture were included. A transconjunctival approach was used in all patients. The mean duration of postoperative follow-up was 29.7±12.3 months. Postoperatively, results and complications such as infection and implant extrusion were followed-up on the first day, the first week, monthly for the first 3 months and then every 3-6 months thereafter. Results: All 21 patients had symptomatic diplopia before surgery. The diplopia resolved in 14 patients and improved in seven patients within the first month after surgery. All patients except one were free from diplopia at follow-up periods exceeding 6 months. Preoperative enophthalmos resolved in four of seven patients and improved in three. None of the patients developed orbital infection, implant exposure or migration, worsening diplopia, infraorbital anesthesia or loss of vision during follow-up. Conclusion: The study demonstrated that porous polyethylene implants in the repair of orbital wall fractures had good results with few complications.",
keywords = "Blowout fracture, Orbital implant, Porous polyethylene",
author = "Lin, {I. Chan} and Liao, {Shu Lang} and Lin, {L. L K}",
year = "2007",
month = "1",
language = "English",
volume = "106",
pages = "51--57",
journal = "Journal of the Formosan Medical Association",
issn = "0929-6646",
publisher = "Elsevier Science Publishers B.V.",
number = "1",

}

TY - JOUR

T1 - Porous polyethylene implants in orbital floor reconstruction

AU - Lin, I. Chan

AU - Liao, Shu Lang

AU - Lin, L. L K

PY - 2007/1

Y1 - 2007/1

N2 - Background/Purpose: Various alloplastic materials are used in orbital wall reconstruction. This study investigated the outcome of patients treated with porous polyethylene sheet implants in the reconstruction of orbital floor fracture. Methods: Twenty-one patients who underwent orbital reconstructions using 0.85-mm porous polyethylene sheets for the repair of orbital floor fracture were included. A transconjunctival approach was used in all patients. The mean duration of postoperative follow-up was 29.7±12.3 months. Postoperatively, results and complications such as infection and implant extrusion were followed-up on the first day, the first week, monthly for the first 3 months and then every 3-6 months thereafter. Results: All 21 patients had symptomatic diplopia before surgery. The diplopia resolved in 14 patients and improved in seven patients within the first month after surgery. All patients except one were free from diplopia at follow-up periods exceeding 6 months. Preoperative enophthalmos resolved in four of seven patients and improved in three. None of the patients developed orbital infection, implant exposure or migration, worsening diplopia, infraorbital anesthesia or loss of vision during follow-up. Conclusion: The study demonstrated that porous polyethylene implants in the repair of orbital wall fractures had good results with few complications.

AB - Background/Purpose: Various alloplastic materials are used in orbital wall reconstruction. This study investigated the outcome of patients treated with porous polyethylene sheet implants in the reconstruction of orbital floor fracture. Methods: Twenty-one patients who underwent orbital reconstructions using 0.85-mm porous polyethylene sheets for the repair of orbital floor fracture were included. A transconjunctival approach was used in all patients. The mean duration of postoperative follow-up was 29.7±12.3 months. Postoperatively, results and complications such as infection and implant extrusion were followed-up on the first day, the first week, monthly for the first 3 months and then every 3-6 months thereafter. Results: All 21 patients had symptomatic diplopia before surgery. The diplopia resolved in 14 patients and improved in seven patients within the first month after surgery. All patients except one were free from diplopia at follow-up periods exceeding 6 months. Preoperative enophthalmos resolved in four of seven patients and improved in three. None of the patients developed orbital infection, implant exposure or migration, worsening diplopia, infraorbital anesthesia or loss of vision during follow-up. Conclusion: The study demonstrated that porous polyethylene implants in the repair of orbital wall fractures had good results with few complications.

KW - Blowout fracture

KW - Orbital implant

KW - Porous polyethylene

UR - http://www.scopus.com/inward/record.url?scp=33846880291&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846880291&partnerID=8YFLogxK

M3 - Article

VL - 106

SP - 51

EP - 57

JO - Journal of the Formosan Medical Association

JF - Journal of the Formosan Medical Association