Modeling the formation and assessing the risk of disinfection by-products in water distribution systems

E. E. Chang, Hsiu Chi Guo, I. Shu Li, Pen Chi Chiang, Chin Pao Huang

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The effect of water quality parameters and operation conditions of water treatment on the formation of trihalomethanes (THM) and haloacetic acids (HAA) in pilot-scale reactor and water distribution system were investigated. Results indicated that dissolved organic carbon and THM formation increased while the concentration of free chlorine decreased along the length of pipeline from the water treatment plant; but HAA formation showed no relationship with the pipeline length. THM concentration was predicted with hydraulic analytic software, namely WaterCAD. The predicted THM data were within ±10% of measurements; HAA had a relatively high error of ±16% due to complex bio-decomposition reactions occurred in the distribution system. Both the hazardous quotient and cancer risk of THM in the water distribution system of an advanced water treatment plant were much lower than those of a conventional water treatment plant; there was no significant difference in hazard quotient and cancer risk of HAA in the above two water distribution systems.

Original languageEnglish
Pages (from-to)1185-1194
Number of pages10
JournalJournal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering
Volume45
Issue number10
DOIs
Publication statusPublished - Aug 2010

Fingerprint

Water distribution systems
Disinfection
Water treatment plants
Byproducts
Acids
Pipelines
Organic carbon
Water treatment
Chlorine
Water quality
Hazards
Hydraulics
Decomposition

Keywords

  • disinfection by-product formation
  • hazard quotient
  • overall cancer risk
  • Pilot-scale reactor
  • risk assessment
  • water distribution system

ASJC Scopus subject areas

  • Environmental Engineering

Cite this

Modeling the formation and assessing the risk of disinfection by-products in water distribution systems. / Chang, E. E.; Guo, Hsiu Chi; Li, I. Shu; Chiang, Pen Chi; Huang, Chin Pao.

In: Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, Vol. 45, No. 10, 08.2010, p. 1185-1194.

Research output: Contribution to journalArticle

@article{f068ce1c42384fb9996e96dc1f1abda0,
title = "Modeling the formation and assessing the risk of disinfection by-products in water distribution systems",
abstract = "The effect of water quality parameters and operation conditions of water treatment on the formation of trihalomethanes (THM) and haloacetic acids (HAA) in pilot-scale reactor and water distribution system were investigated. Results indicated that dissolved organic carbon and THM formation increased while the concentration of free chlorine decreased along the length of pipeline from the water treatment plant; but HAA formation showed no relationship with the pipeline length. THM concentration was predicted with hydraulic analytic software, namely WaterCAD. The predicted THM data were within ±10{\%} of measurements; HAA had a relatively high error of ±16{\%} due to complex bio-decomposition reactions occurred in the distribution system. Both the hazardous quotient and cancer risk of THM in the water distribution system of an advanced water treatment plant were much lower than those of a conventional water treatment plant; there was no significant difference in hazard quotient and cancer risk of HAA in the above two water distribution systems.",
keywords = "disinfection by-product formation, hazard quotient, overall cancer risk, Pilot-scale reactor, risk assessment, water distribution system",
author = "Chang, {E. E.} and Guo, {Hsiu Chi} and Li, {I. Shu} and Chiang, {Pen Chi} and Huang, {Chin Pao}",
year = "2010",
month = "8",
doi = "10.1080/10934529.2010.493776",
language = "English",
volume = "45",
pages = "1185--1194",
journal = "Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering",
issn = "1093-4529",
publisher = "Taylor and Francis Ltd.",
number = "10",

}

TY - JOUR

T1 - Modeling the formation and assessing the risk of disinfection by-products in water distribution systems

AU - Chang, E. E.

AU - Guo, Hsiu Chi

AU - Li, I. Shu

AU - Chiang, Pen Chi

AU - Huang, Chin Pao

PY - 2010/8

Y1 - 2010/8

N2 - The effect of water quality parameters and operation conditions of water treatment on the formation of trihalomethanes (THM) and haloacetic acids (HAA) in pilot-scale reactor and water distribution system were investigated. Results indicated that dissolved organic carbon and THM formation increased while the concentration of free chlorine decreased along the length of pipeline from the water treatment plant; but HAA formation showed no relationship with the pipeline length. THM concentration was predicted with hydraulic analytic software, namely WaterCAD. The predicted THM data were within ±10% of measurements; HAA had a relatively high error of ±16% due to complex bio-decomposition reactions occurred in the distribution system. Both the hazardous quotient and cancer risk of THM in the water distribution system of an advanced water treatment plant were much lower than those of a conventional water treatment plant; there was no significant difference in hazard quotient and cancer risk of HAA in the above two water distribution systems.

AB - The effect of water quality parameters and operation conditions of water treatment on the formation of trihalomethanes (THM) and haloacetic acids (HAA) in pilot-scale reactor and water distribution system were investigated. Results indicated that dissolved organic carbon and THM formation increased while the concentration of free chlorine decreased along the length of pipeline from the water treatment plant; but HAA formation showed no relationship with the pipeline length. THM concentration was predicted with hydraulic analytic software, namely WaterCAD. The predicted THM data were within ±10% of measurements; HAA had a relatively high error of ±16% due to complex bio-decomposition reactions occurred in the distribution system. Both the hazardous quotient and cancer risk of THM in the water distribution system of an advanced water treatment plant were much lower than those of a conventional water treatment plant; there was no significant difference in hazard quotient and cancer risk of HAA in the above two water distribution systems.

KW - disinfection by-product formation

KW - hazard quotient

KW - overall cancer risk

KW - Pilot-scale reactor

KW - risk assessment

KW - water distribution system

UR - http://www.scopus.com/inward/record.url?scp=77953856944&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953856944&partnerID=8YFLogxK

U2 - 10.1080/10934529.2010.493776

DO - 10.1080/10934529.2010.493776

M3 - Article

C2 - 20563912

AN - SCOPUS:77953856944

VL - 45

SP - 1185

EP - 1194

JO - Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering

JF - Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering

SN - 1093-4529

IS - 10

ER -