Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA

Kuo Hsiang Chuang, Shey Cherng Tzou, Ta Chun Cheng, Chien Han Kao, Wei Lung Tseng, Jentale Shiea, Kuang Wen Liao, Yun Ming Wang, Ya Chen Chang, Bo Jyun Huango, Chang Jer Wu, Pei Yu Chu, Steve R. Roffler, Tian Lu Cheng

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Polyethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/αPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification. The αPEG cell-coated plate bound biotinylated PEG5K (CH3-PEG5K-biotin) and CH3-PEG5k- 131I more effectively than did a traditional anti-PEG antibody-coated plate. Competitive binding between PEG (2, 5,10, or 20 kDa) and a known amount of CH3-PEG5K-biotin allowed construction of a reproducible competition curve. The αPEG cellbased competition ELISA measured small molecules derivatized by PEG 2K, PEG5K, PEG10k, PEG20k. and PEG5k at concentrations as low as 58.6,14.6,3.7,3.7, and 14.6 ng/mL, respectively. Notably, the presence of serum or bovine serum albumin enhanced PEG measurement by the αPEG cell-based competition ELISA. Finally, we show here that the αPEG cell-based competition ELISA accurately delineated the pharmacokinetics of PEG5K, comparable to those determined by direct measurement of radioactivity in blood after intravenous injection of CH3- PEG5K- 131I into mice. This quantitative strategy may provide a simple and sensitive method for quantifying PEG and PEGylated small molecules in vivo.

Original languageEnglish
Pages (from-to)2355-2362
Number of pages8
JournalAnalytical Chemistry
Volume82
Issue number6
DOIs
Publication statusPublished - Mar 15 2010
Externally publishedYes

Fingerprint

Immunosorbents
Polyethylene glycols
Assays
Enzymes
Biotin
Molecules
Pharmacokinetics
Antibodies
Radioactivity
Bovine Serum Albumin
Medicine

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Chuang, K. H., Tzou, S. C., Cheng, T. C., Kao, C. H., Tseng, W. L., Shiea, J., ... Cheng, T. L. (2010). Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA. Analytical Chemistry, 82(6), 2355-2362. https://doi.org/10.1021/ac902548m

Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA. / Chuang, Kuo Hsiang; Tzou, Shey Cherng; Cheng, Ta Chun; Kao, Chien Han; Tseng, Wei Lung; Shiea, Jentale; Liao, Kuang Wen; Wang, Yun Ming; Chang, Ya Chen; Huango, Bo Jyun; Wu, Chang Jer; Chu, Pei Yu; Roffler, Steve R.; Cheng, Tian Lu.

In: Analytical Chemistry, Vol. 82, No. 6, 15.03.2010, p. 2355-2362.

Research output: Contribution to journalArticle

Chuang, KH, Tzou, SC, Cheng, TC, Kao, CH, Tseng, WL, Shiea, J, Liao, KW, Wang, YM, Chang, YC, Huango, BJ, Wu, CJ, Chu, PY, Roffler, SR & Cheng, TL 2010, 'Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA', Analytical Chemistry, vol. 82, no. 6, pp. 2355-2362. https://doi.org/10.1021/ac902548m
Chuang, Kuo Hsiang ; Tzou, Shey Cherng ; Cheng, Ta Chun ; Kao, Chien Han ; Tseng, Wei Lung ; Shiea, Jentale ; Liao, Kuang Wen ; Wang, Yun Ming ; Chang, Ya Chen ; Huango, Bo Jyun ; Wu, Chang Jer ; Chu, Pei Yu ; Roffler, Steve R. ; Cheng, Tian Lu. / Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA. In: Analytical Chemistry. 2010 ; Vol. 82, No. 6. pp. 2355-2362.
@article{047e3c4d353f41eb917a70051d158a0e,
title = "Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA",
abstract = "Polyethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/αPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification. The αPEG cell-coated plate bound biotinylated PEG5K (CH3-PEG5K-biotin) and CH3-PEG5k- 131I more effectively than did a traditional anti-PEG antibody-coated plate. Competitive binding between PEG (2, 5,10, or 20 kDa) and a known amount of CH3-PEG5K-biotin allowed construction of a reproducible competition curve. The αPEG cellbased competition ELISA measured small molecules derivatized by PEG 2K, PEG5K, PEG10k, PEG20k. and PEG5k at concentrations as low as 58.6,14.6,3.7,3.7, and 14.6 ng/mL, respectively. Notably, the presence of serum or bovine serum albumin enhanced PEG measurement by the αPEG cell-based competition ELISA. Finally, we show here that the αPEG cell-based competition ELISA accurately delineated the pharmacokinetics of PEG5K, comparable to those determined by direct measurement of radioactivity in blood after intravenous injection of CH3- PEG5K- 131I into mice. This quantitative strategy may provide a simple and sensitive method for quantifying PEG and PEGylated small molecules in vivo.",
author = "Chuang, {Kuo Hsiang} and Tzou, {Shey Cherng} and Cheng, {Ta Chun} and Kao, {Chien Han} and Tseng, {Wei Lung} and Jentale Shiea and Liao, {Kuang Wen} and Wang, {Yun Ming} and Chang, {Ya Chen} and Huango, {Bo Jyun} and Wu, {Chang Jer} and Chu, {Pei Yu} and Roffler, {Steve R.} and Cheng, {Tian Lu}",
year = "2010",
month = "3",
day = "15",
doi = "10.1021/ac902548m",
language = "English",
volume = "82",
pages = "2355--2362",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "6",

}

TY - JOUR

T1 - Measurement of Poly(ethylene glycol) by Cell-Based Anti-poly(ethylene glycol) ELISA

AU - Chuang, Kuo Hsiang

AU - Tzou, Shey Cherng

AU - Cheng, Ta Chun

AU - Kao, Chien Han

AU - Tseng, Wei Lung

AU - Shiea, Jentale

AU - Liao, Kuang Wen

AU - Wang, Yun Ming

AU - Chang, Ya Chen

AU - Huango, Bo Jyun

AU - Wu, Chang Jer

AU - Chu, Pei Yu

AU - Roffler, Steve R.

AU - Cheng, Tian Lu

PY - 2010/3/15

Y1 - 2010/3/15

N2 - Polyethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/αPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification. The αPEG cell-coated plate bound biotinylated PEG5K (CH3-PEG5K-biotin) and CH3-PEG5k- 131I more effectively than did a traditional anti-PEG antibody-coated plate. Competitive binding between PEG (2, 5,10, or 20 kDa) and a known amount of CH3-PEG5K-biotin allowed construction of a reproducible competition curve. The αPEG cellbased competition ELISA measured small molecules derivatized by PEG 2K, PEG5K, PEG10k, PEG20k. and PEG5k at concentrations as low as 58.6,14.6,3.7,3.7, and 14.6 ng/mL, respectively. Notably, the presence of serum or bovine serum albumin enhanced PEG measurement by the αPEG cell-based competition ELISA. Finally, we show here that the αPEG cell-based competition ELISA accurately delineated the pharmacokinetics of PEG5K, comparable to those determined by direct measurement of radioactivity in blood after intravenous injection of CH3- PEG5K- 131I into mice. This quantitative strategy may provide a simple and sensitive method for quantifying PEG and PEGylated small molecules in vivo.

AB - Polyethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/αPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification. The αPEG cell-coated plate bound biotinylated PEG5K (CH3-PEG5K-biotin) and CH3-PEG5k- 131I more effectively than did a traditional anti-PEG antibody-coated plate. Competitive binding between PEG (2, 5,10, or 20 kDa) and a known amount of CH3-PEG5K-biotin allowed construction of a reproducible competition curve. The αPEG cellbased competition ELISA measured small molecules derivatized by PEG 2K, PEG5K, PEG10k, PEG20k. and PEG5k at concentrations as low as 58.6,14.6,3.7,3.7, and 14.6 ng/mL, respectively. Notably, the presence of serum or bovine serum albumin enhanced PEG measurement by the αPEG cell-based competition ELISA. Finally, we show here that the αPEG cell-based competition ELISA accurately delineated the pharmacokinetics of PEG5K, comparable to those determined by direct measurement of radioactivity in blood after intravenous injection of CH3- PEG5K- 131I into mice. This quantitative strategy may provide a simple and sensitive method for quantifying PEG and PEGylated small molecules in vivo.

UR - http://www.scopus.com/inward/record.url?scp=77949840263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77949840263&partnerID=8YFLogxK

U2 - 10.1021/ac902548m

DO - 10.1021/ac902548m

M3 - Article

C2 - 20178318

AN - SCOPUS:77949840263

VL - 82

SP - 2355

EP - 2362

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 6

ER -