Lower prevalence of depression in hemodialysis patients who use polysulfone dialyzers

Heng Jung Hsu, Chih Ken Chen, Mai Szu Wu

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Background: Depression is common in dialysis patients and is also associated with the presence of chronic inflammation. Dialysis patients who use polysulfone dialyzers are less likely to have inflammation. It is unknown whether the use of polysulfone dialyzers is associated with lower prevalence of depression. Method: The aim of this cross-sectional study is to examine the association between the use of polysulfone dialyzers and depression in dialysis patients. This association was examined by use of univariate and multivariate analysis. Results: Depression affected 35% of our hemodialysis patients. Compared with nondepressed patients, depressed patients were more likely to be male, thinner (lower body mass index), and have more comorbidities. Depression was also associated with the use of cellulose derivative dialyzers (p = 0.008). In multivariate analysis with stepwise regression, gender, albumin, number of comorbidities, and BMI lost their significance. However, the use of polysulfone dialyzers remained correlated with a lower prevalence of depression (odds ratio 0.063, 95% confidence interval 0.01-0.43; p = 0.005). This indicates that the type of dialyzer is independently associated with depression in these hemodialysis patients. Conclusion: The prevalence of depression was lower in patients using polysulfone dialyzers than cellulose derivative dialyzers. Using more biocompatible dialyzers appears to be associated with better mental health in hemodialysis patients.

Original languageEnglish
Pages (from-to)592-597
Number of pages6
JournalAmerican Journal of Nephrology
Volume29
Issue number6
DOIs
Publication statusPublished - Jun 2009
Externally publishedYes

Fingerprint

Renal Dialysis
Depression
Dialysis
Cellulose
Comorbidity
Multivariate Analysis
Inflammation
polysulfone P 1700
Albumins
Mental Health
Body Mass Index
Cross-Sectional Studies
Odds Ratio
Confidence Intervals

Keywords

  • Depression
  • Dialyzer
  • End-stage renal disease
  • Hemodialysis
  • Polysulfone

ASJC Scopus subject areas

  • Nephrology

Cite this

Lower prevalence of depression in hemodialysis patients who use polysulfone dialyzers. / Hsu, Heng Jung; Chen, Chih Ken; Wu, Mai Szu.

In: American Journal of Nephrology, Vol. 29, No. 6, 06.2009, p. 592-597.

Research output: Contribution to journalArticle

@article{0503ea185c404357967fa9b52833f931,
title = "Lower prevalence of depression in hemodialysis patients who use polysulfone dialyzers",
abstract = "Background: Depression is common in dialysis patients and is also associated with the presence of chronic inflammation. Dialysis patients who use polysulfone dialyzers are less likely to have inflammation. It is unknown whether the use of polysulfone dialyzers is associated with lower prevalence of depression. Method: The aim of this cross-sectional study is to examine the association between the use of polysulfone dialyzers and depression in dialysis patients. This association was examined by use of univariate and multivariate analysis. Results: Depression affected 35{\%} of our hemodialysis patients. Compared with nondepressed patients, depressed patients were more likely to be male, thinner (lower body mass index), and have more comorbidities. Depression was also associated with the use of cellulose derivative dialyzers (p = 0.008). In multivariate analysis with stepwise regression, gender, albumin, number of comorbidities, and BMI lost their significance. However, the use of polysulfone dialyzers remained correlated with a lower prevalence of depression (odds ratio 0.063, 95{\%} confidence interval 0.01-0.43; p = 0.005). This indicates that the type of dialyzer is independently associated with depression in these hemodialysis patients. Conclusion: The prevalence of depression was lower in patients using polysulfone dialyzers than cellulose derivative dialyzers. Using more biocompatible dialyzers appears to be associated with better mental health in hemodialysis patients.",
keywords = "Depression, Dialyzer, End-stage renal disease, Hemodialysis, Polysulfone",
author = "Hsu, {Heng Jung} and Chen, {Chih Ken} and Wu, {Mai Szu}",
year = "2009",
month = "6",
doi = "10.1159/000193144",
language = "English",
volume = "29",
pages = "592--597",
journal = "American Journal of Nephrology",
issn = "0250-8095",
publisher = "S. Karger AG",
number = "6",

}

TY - JOUR

T1 - Lower prevalence of depression in hemodialysis patients who use polysulfone dialyzers

AU - Hsu, Heng Jung

AU - Chen, Chih Ken

AU - Wu, Mai Szu

PY - 2009/6

Y1 - 2009/6

N2 - Background: Depression is common in dialysis patients and is also associated with the presence of chronic inflammation. Dialysis patients who use polysulfone dialyzers are less likely to have inflammation. It is unknown whether the use of polysulfone dialyzers is associated with lower prevalence of depression. Method: The aim of this cross-sectional study is to examine the association between the use of polysulfone dialyzers and depression in dialysis patients. This association was examined by use of univariate and multivariate analysis. Results: Depression affected 35% of our hemodialysis patients. Compared with nondepressed patients, depressed patients were more likely to be male, thinner (lower body mass index), and have more comorbidities. Depression was also associated with the use of cellulose derivative dialyzers (p = 0.008). In multivariate analysis with stepwise regression, gender, albumin, number of comorbidities, and BMI lost their significance. However, the use of polysulfone dialyzers remained correlated with a lower prevalence of depression (odds ratio 0.063, 95% confidence interval 0.01-0.43; p = 0.005). This indicates that the type of dialyzer is independently associated with depression in these hemodialysis patients. Conclusion: The prevalence of depression was lower in patients using polysulfone dialyzers than cellulose derivative dialyzers. Using more biocompatible dialyzers appears to be associated with better mental health in hemodialysis patients.

AB - Background: Depression is common in dialysis patients and is also associated with the presence of chronic inflammation. Dialysis patients who use polysulfone dialyzers are less likely to have inflammation. It is unknown whether the use of polysulfone dialyzers is associated with lower prevalence of depression. Method: The aim of this cross-sectional study is to examine the association between the use of polysulfone dialyzers and depression in dialysis patients. This association was examined by use of univariate and multivariate analysis. Results: Depression affected 35% of our hemodialysis patients. Compared with nondepressed patients, depressed patients were more likely to be male, thinner (lower body mass index), and have more comorbidities. Depression was also associated with the use of cellulose derivative dialyzers (p = 0.008). In multivariate analysis with stepwise regression, gender, albumin, number of comorbidities, and BMI lost their significance. However, the use of polysulfone dialyzers remained correlated with a lower prevalence of depression (odds ratio 0.063, 95% confidence interval 0.01-0.43; p = 0.005). This indicates that the type of dialyzer is independently associated with depression in these hemodialysis patients. Conclusion: The prevalence of depression was lower in patients using polysulfone dialyzers than cellulose derivative dialyzers. Using more biocompatible dialyzers appears to be associated with better mental health in hemodialysis patients.

KW - Depression

KW - Dialyzer

KW - End-stage renal disease

KW - Hemodialysis

KW - Polysulfone

UR - http://www.scopus.com/inward/record.url?scp=58149476413&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58149476413&partnerID=8YFLogxK

U2 - 10.1159/000193144

DO - 10.1159/000193144

M3 - Article

C2 - 19145074

AN - SCOPUS:58149476413

VL - 29

SP - 592

EP - 597

JO - American Journal of Nephrology

JF - American Journal of Nephrology

SN - 0250-8095

IS - 6

ER -