Intralesional photocoagulation of vascular anomalies of the tongue

Cheng Jen Chang, David M. Fisher, Yu Ray Chen

Research output: Contribution to journalArticle

50 Citations (Scopus)

Abstract

Vascular anomalies remain a challenge for patients and reconstructive surgeons. Recently, promising results have been reported using intralesional photocoagulation (ILP) to treat large, deep vascular lesions. We report our experience in treating 12 patients with vascular anomalies of the tongue (10 venous malformations and two haemangiomas) using intralesional photocoagulation. All patients were treated with a Nd:YAG (neodymium:yttrium-aluminium-garnet) (1064 nm) laser (Sharplan, Inc., NJ, USA) delivered with a 600 μm optical fibre. Laser power was set at 7 or 10 W, delivered with a pulse duration of 10 s. Laser energy was delivered to all areas of the vascular lesion. Heat, visible shrinkage and firmness of the lesion signalled the end-point of treatment. The mean follow-up period was 9.5 months (range 3-20 months). All patients demonstrated improvement as judged by a clinical assessment of the reduction in lesion size (mean reduction = 87%, range 60-100%). Three patients (25%) had complications attributed to photocoagulation. Energy delivered too superficially resulted in ulceration or scarring. These complications should be avoidable if this potential for harm is kept in mind.

Original languageEnglish
Pages (from-to)178-181
Number of pages4
JournalBritish Journal of Plastic Surgery
Volume52
Issue number3
DOIs
Publication statusPublished - Jan 1 1999
Externally publishedYes

Fingerprint

Light Coagulation
Tongue
Blood Vessels
Lasers
Neodymium
Optical Fibers
Hemangioma
Cicatrix
Hot Temperature

Keywords

  • Haemangioma
  • Laser
  • Tongue
  • Vascular malformation

ASJC Scopus subject areas

  • Surgery
  • Otorhinolaryngology

Cite this

Intralesional photocoagulation of vascular anomalies of the tongue. / Chang, Cheng Jen; Fisher, David M.; Chen, Yu Ray.

In: British Journal of Plastic Surgery, Vol. 52, No. 3, 01.01.1999, p. 178-181.

Research output: Contribution to journalArticle

Chang, Cheng Jen ; Fisher, David M. ; Chen, Yu Ray. / Intralesional photocoagulation of vascular anomalies of the tongue. In: British Journal of Plastic Surgery. 1999 ; Vol. 52, No. 3. pp. 178-181.
@article{127a2bddabff4a65837de50375ec5b1b,
title = "Intralesional photocoagulation of vascular anomalies of the tongue",
abstract = "Vascular anomalies remain a challenge for patients and reconstructive surgeons. Recently, promising results have been reported using intralesional photocoagulation (ILP) to treat large, deep vascular lesions. We report our experience in treating 12 patients with vascular anomalies of the tongue (10 venous malformations and two haemangiomas) using intralesional photocoagulation. All patients were treated with a Nd:YAG (neodymium:yttrium-aluminium-garnet) (1064 nm) laser (Sharplan, Inc., NJ, USA) delivered with a 600 μm optical fibre. Laser power was set at 7 or 10 W, delivered with a pulse duration of 10 s. Laser energy was delivered to all areas of the vascular lesion. Heat, visible shrinkage and firmness of the lesion signalled the end-point of treatment. The mean follow-up period was 9.5 months (range 3-20 months). All patients demonstrated improvement as judged by a clinical assessment of the reduction in lesion size (mean reduction = 87{\%}, range 60-100{\%}). Three patients (25{\%}) had complications attributed to photocoagulation. Energy delivered too superficially resulted in ulceration or scarring. These complications should be avoidable if this potential for harm is kept in mind.",
keywords = "Haemangioma, Laser, Tongue, Vascular malformation",
author = "Chang, {Cheng Jen} and Fisher, {David M.} and Chen, {Yu Ray}",
year = "1999",
month = "1",
day = "1",
doi = "10.1054/bjps.1998.3056",
language = "English",
volume = "52",
pages = "178--181",
journal = "Journal of Plastic, Reconstructive and Aesthetic Surgery",
issn = "1748-6815",
publisher = "Churchill Livingstone",
number = "3",

}

TY - JOUR

T1 - Intralesional photocoagulation of vascular anomalies of the tongue

AU - Chang, Cheng Jen

AU - Fisher, David M.

AU - Chen, Yu Ray

PY - 1999/1/1

Y1 - 1999/1/1

N2 - Vascular anomalies remain a challenge for patients and reconstructive surgeons. Recently, promising results have been reported using intralesional photocoagulation (ILP) to treat large, deep vascular lesions. We report our experience in treating 12 patients with vascular anomalies of the tongue (10 venous malformations and two haemangiomas) using intralesional photocoagulation. All patients were treated with a Nd:YAG (neodymium:yttrium-aluminium-garnet) (1064 nm) laser (Sharplan, Inc., NJ, USA) delivered with a 600 μm optical fibre. Laser power was set at 7 or 10 W, delivered with a pulse duration of 10 s. Laser energy was delivered to all areas of the vascular lesion. Heat, visible shrinkage and firmness of the lesion signalled the end-point of treatment. The mean follow-up period was 9.5 months (range 3-20 months). All patients demonstrated improvement as judged by a clinical assessment of the reduction in lesion size (mean reduction = 87%, range 60-100%). Three patients (25%) had complications attributed to photocoagulation. Energy delivered too superficially resulted in ulceration or scarring. These complications should be avoidable if this potential for harm is kept in mind.

AB - Vascular anomalies remain a challenge for patients and reconstructive surgeons. Recently, promising results have been reported using intralesional photocoagulation (ILP) to treat large, deep vascular lesions. We report our experience in treating 12 patients with vascular anomalies of the tongue (10 venous malformations and two haemangiomas) using intralesional photocoagulation. All patients were treated with a Nd:YAG (neodymium:yttrium-aluminium-garnet) (1064 nm) laser (Sharplan, Inc., NJ, USA) delivered with a 600 μm optical fibre. Laser power was set at 7 or 10 W, delivered with a pulse duration of 10 s. Laser energy was delivered to all areas of the vascular lesion. Heat, visible shrinkage and firmness of the lesion signalled the end-point of treatment. The mean follow-up period was 9.5 months (range 3-20 months). All patients demonstrated improvement as judged by a clinical assessment of the reduction in lesion size (mean reduction = 87%, range 60-100%). Three patients (25%) had complications attributed to photocoagulation. Energy delivered too superficially resulted in ulceration or scarring. These complications should be avoidable if this potential for harm is kept in mind.

KW - Haemangioma

KW - Laser

KW - Tongue

KW - Vascular malformation

UR - http://www.scopus.com/inward/record.url?scp=0033119822&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033119822&partnerID=8YFLogxK

U2 - 10.1054/bjps.1998.3056

DO - 10.1054/bjps.1998.3056

M3 - Article

C2 - 10474467

AN - SCOPUS:0033119822

VL - 52

SP - 178

EP - 181

JO - Journal of Plastic, Reconstructive and Aesthetic Surgery

JF - Journal of Plastic, Reconstructive and Aesthetic Surgery

SN - 1748-6815

IS - 3

ER -