Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging

Hsiu Mei Wu, David M. Yousem, Hsiao Wen Chung, Wan Yuo Guo, Cheng Yen Chang, Cheng Yu Chen

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

BACKGROUND AND PURPOSE: High-intensity CSF artifacts at the basal cisterns on MR images are often seen when a fast fluid-attenuated inversion recovery (FLAIR) technique is used. We investigated the influences of four optional fast-FLAIR sequence parameters on the high-intensity CSF artifacts. METHODS: A total of 377 patients (age range, 1 week to 91 years; mean 40.6 years; 186 female, 191 male) were examined with axial fast-FLAIR images obtained (TR/TEeff/TI, 8800/133/2200) with a 1.5-T system during 6 months. The effects of the optional addition of inferior inflow saturation (thickness, 80 mm), section flow compensation, and tailored radiofrequency (TRF) pulses, plus the choice of interleaving acquisition factors of 2 or 3, were evaluated for the presence of high-intensity CSF artifacts on the fast-FLAIR images. Two radiologists independently reviewed the fast-FLAIR images in 76 patients; afterward, a single observer reviewed the remainder of the images. RESULTS: The interobserver agreement rate in 76 cases was more than 90%. The use of TRF and/or three interleaving acquisitions resulted in a substantial reduction in the incidence of high-intensity CSF artifacts from about 80% to 40% (P <.05, two-sample two-sided Z test). Inferior inflow saturation and section flow compensation did not significantly improve image quality (P > .05). The results were consistent with the image quality ranking obtained in five healthy volunteers. CONCLUSION: The appropriate choice of sequence parameters in fast-FLAIR imaging reduces the incidence of high-intensity CSF artifacts that are frequently encountered in the presence of rapid CSF flow.

Original languageEnglish
Pages (from-to)393-399
Number of pages7
JournalAmerican Journal of Neuroradiology
Volume23
Issue number3
Publication statusPublished - 2002
Externally publishedYes

Fingerprint

Artifacts
Cerebrospinal Fluid
Sequence Inversion
Incidence
Healthy Volunteers

ASJC Scopus subject areas

  • Clinical Neurology
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging. / Wu, Hsiu Mei; Yousem, David M.; Chung, Hsiao Wen; Guo, Wan Yuo; Chang, Cheng Yen; Chen, Cheng Yu.

In: American Journal of Neuroradiology, Vol. 23, No. 3, 2002, p. 393-399.

Research output: Contribution to journalArticle

Wu, Hsiu Mei ; Yousem, David M. ; Chung, Hsiao Wen ; Guo, Wan Yuo ; Chang, Cheng Yen ; Chen, Cheng Yu. / Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging. In: American Journal of Neuroradiology. 2002 ; Vol. 23, No. 3. pp. 393-399.
@article{76d2e231b25a4f9db04c442a62dfad3b,
title = "Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging",
abstract = "BACKGROUND AND PURPOSE: High-intensity CSF artifacts at the basal cisterns on MR images are often seen when a fast fluid-attenuated inversion recovery (FLAIR) technique is used. We investigated the influences of four optional fast-FLAIR sequence parameters on the high-intensity CSF artifacts. METHODS: A total of 377 patients (age range, 1 week to 91 years; mean 40.6 years; 186 female, 191 male) were examined with axial fast-FLAIR images obtained (TR/TEeff/TI, 8800/133/2200) with a 1.5-T system during 6 months. The effects of the optional addition of inferior inflow saturation (thickness, 80 mm), section flow compensation, and tailored radiofrequency (TRF) pulses, plus the choice of interleaving acquisition factors of 2 or 3, were evaluated for the presence of high-intensity CSF artifacts on the fast-FLAIR images. Two radiologists independently reviewed the fast-FLAIR images in 76 patients; afterward, a single observer reviewed the remainder of the images. RESULTS: The interobserver agreement rate in 76 cases was more than 90{\%}. The use of TRF and/or three interleaving acquisitions resulted in a substantial reduction in the incidence of high-intensity CSF artifacts from about 80{\%} to 40{\%} (P <.05, two-sample two-sided Z test). Inferior inflow saturation and section flow compensation did not significantly improve image quality (P > .05). The results were consistent with the image quality ranking obtained in five healthy volunteers. CONCLUSION: The appropriate choice of sequence parameters in fast-FLAIR imaging reduces the incidence of high-intensity CSF artifacts that are frequently encountered in the presence of rapid CSF flow.",
author = "Wu, {Hsiu Mei} and Yousem, {David M.} and Chung, {Hsiao Wen} and Guo, {Wan Yuo} and Chang, {Cheng Yen} and Chen, {Cheng Yu}",
year = "2002",
language = "English",
volume = "23",
pages = "393--399",
journal = "American Journal of Neuroradiology",
issn = "0195-6108",
publisher = "American Society of Neuroradiology",
number = "3",

}

TY - JOUR

T1 - Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging

AU - Wu, Hsiu Mei

AU - Yousem, David M.

AU - Chung, Hsiao Wen

AU - Guo, Wan Yuo

AU - Chang, Cheng Yen

AU - Chen, Cheng Yu

PY - 2002

Y1 - 2002

N2 - BACKGROUND AND PURPOSE: High-intensity CSF artifacts at the basal cisterns on MR images are often seen when a fast fluid-attenuated inversion recovery (FLAIR) technique is used. We investigated the influences of four optional fast-FLAIR sequence parameters on the high-intensity CSF artifacts. METHODS: A total of 377 patients (age range, 1 week to 91 years; mean 40.6 years; 186 female, 191 male) were examined with axial fast-FLAIR images obtained (TR/TEeff/TI, 8800/133/2200) with a 1.5-T system during 6 months. The effects of the optional addition of inferior inflow saturation (thickness, 80 mm), section flow compensation, and tailored radiofrequency (TRF) pulses, plus the choice of interleaving acquisition factors of 2 or 3, were evaluated for the presence of high-intensity CSF artifacts on the fast-FLAIR images. Two radiologists independently reviewed the fast-FLAIR images in 76 patients; afterward, a single observer reviewed the remainder of the images. RESULTS: The interobserver agreement rate in 76 cases was more than 90%. The use of TRF and/or three interleaving acquisitions resulted in a substantial reduction in the incidence of high-intensity CSF artifacts from about 80% to 40% (P <.05, two-sample two-sided Z test). Inferior inflow saturation and section flow compensation did not significantly improve image quality (P > .05). The results were consistent with the image quality ranking obtained in five healthy volunteers. CONCLUSION: The appropriate choice of sequence parameters in fast-FLAIR imaging reduces the incidence of high-intensity CSF artifacts that are frequently encountered in the presence of rapid CSF flow.

AB - BACKGROUND AND PURPOSE: High-intensity CSF artifacts at the basal cisterns on MR images are often seen when a fast fluid-attenuated inversion recovery (FLAIR) technique is used. We investigated the influences of four optional fast-FLAIR sequence parameters on the high-intensity CSF artifacts. METHODS: A total of 377 patients (age range, 1 week to 91 years; mean 40.6 years; 186 female, 191 male) were examined with axial fast-FLAIR images obtained (TR/TEeff/TI, 8800/133/2200) with a 1.5-T system during 6 months. The effects of the optional addition of inferior inflow saturation (thickness, 80 mm), section flow compensation, and tailored radiofrequency (TRF) pulses, plus the choice of interleaving acquisition factors of 2 or 3, were evaluated for the presence of high-intensity CSF artifacts on the fast-FLAIR images. Two radiologists independently reviewed the fast-FLAIR images in 76 patients; afterward, a single observer reviewed the remainder of the images. RESULTS: The interobserver agreement rate in 76 cases was more than 90%. The use of TRF and/or three interleaving acquisitions resulted in a substantial reduction in the incidence of high-intensity CSF artifacts from about 80% to 40% (P <.05, two-sample two-sided Z test). Inferior inflow saturation and section flow compensation did not significantly improve image quality (P > .05). The results were consistent with the image quality ranking obtained in five healthy volunteers. CONCLUSION: The appropriate choice of sequence parameters in fast-FLAIR imaging reduces the incidence of high-intensity CSF artifacts that are frequently encountered in the presence of rapid CSF flow.

UR - http://www.scopus.com/inward/record.url?scp=0036127690&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036127690&partnerID=8YFLogxK

M3 - Article

VL - 23

SP - 393

EP - 399

JO - American Journal of Neuroradiology

JF - American Journal of Neuroradiology

SN - 0195-6108

IS - 3