Improvement in resolution of laser capture microdissection using near-field probe to capture nanoparticles

Chien Ming Chen, Jen Ai Lee, Chi Fu Yen

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Purpose: A modified laser capture microdissection (LCM) system is developed to improve resolution to 400 nm, using a laser light (808 nm) transmitted by a near-field tip probe. Materials and methods: Using a 150-nm aperture to heat an ethylene vinyl acetate (EVA) film, melted spots on the average of 400 nm in diameter are generated on the underlying target composed of a 20-nm gold-particle monolayer. The near-field tip probe composed of fiber is set on a 2-D nanometer piezoactuator (PZT) for precise capturing of the monolayer of gold particles.The monolayer of gold particles under the target is bound to the EVA film using a laser, while the remaining EVA film stays on the monolayer. Results: The diameter of the melted spots as small as 400 nm are produced and details are provided that demonstrate the feasibility of the nanooperation of this new LCMsystem. Conclusion: The new LCMsystem successfully captures nanoparticles and improves resolution of microdissection to 400 nm. With this LCM system, the isolation of a single organelle or bacterium is possible.

Original languageEnglish
Article number4806083
Pages (from-to)113-119
Number of pages7
JournalIEEE Transactions on Nanobioscience
Volume8
Issue number2
DOIs
Publication statusPublished - Jun 2009

Fingerprint

Microdissection
Laser Capture Microdissection
Gold
Nanoparticles
Monolayers
Ethylene
Lasers
Organelles
Hot Temperature
Bacteria
Light
vinyl acetate
ethylene
Fibers

Keywords

  • Laser capturemicrodissection (LCM)
  • Nanooperation
  • Near-field fiber probe

ASJC Scopus subject areas

  • Pharmaceutical Science
  • Medicine (miscellaneous)
  • Bioengineering
  • Computer Science Applications
  • Biotechnology
  • Biomedical Engineering
  • Electrical and Electronic Engineering

Cite this

Improvement in resolution of laser capture microdissection using near-field probe to capture nanoparticles. / Chen, Chien Ming; Lee, Jen Ai; Yen, Chi Fu.

In: IEEE Transactions on Nanobioscience, Vol. 8, No. 2, 4806083, 06.2009, p. 113-119.

Research output: Contribution to journalArticle

@article{249be403017f45ee9e4a3a702c46dbd5,
title = "Improvement in resolution of laser capture microdissection using near-field probe to capture nanoparticles",
abstract = "Purpose: A modified laser capture microdissection (LCM) system is developed to improve resolution to 400 nm, using a laser light (808 nm) transmitted by a near-field tip probe. Materials and methods: Using a 150-nm aperture to heat an ethylene vinyl acetate (EVA) film, melted spots on the average of 400 nm in diameter are generated on the underlying target composed of a 20-nm gold-particle monolayer. The near-field tip probe composed of fiber is set on a 2-D nanometer piezoactuator (PZT) for precise capturing of the monolayer of gold particles.The monolayer of gold particles under the target is bound to the EVA film using a laser, while the remaining EVA film stays on the monolayer. Results: The diameter of the melted spots as small as 400 nm are produced and details are provided that demonstrate the feasibility of the nanooperation of this new LCMsystem. Conclusion: The new LCMsystem successfully captures nanoparticles and improves resolution of microdissection to 400 nm. With this LCM system, the isolation of a single organelle or bacterium is possible.",
keywords = "Laser capturemicrodissection (LCM), Nanooperation, Near-field fiber probe",
author = "Chen, {Chien Ming} and Lee, {Jen Ai} and Yen, {Chi Fu}",
year = "2009",
month = "6",
doi = "10.1109/TNB.2009.2019698",
language = "English",
volume = "8",
pages = "113--119",
journal = "IEEE Transactions on Nanobioscience",
issn = "1536-1241",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

TY - JOUR

T1 - Improvement in resolution of laser capture microdissection using near-field probe to capture nanoparticles

AU - Chen, Chien Ming

AU - Lee, Jen Ai

AU - Yen, Chi Fu

PY - 2009/6

Y1 - 2009/6

N2 - Purpose: A modified laser capture microdissection (LCM) system is developed to improve resolution to 400 nm, using a laser light (808 nm) transmitted by a near-field tip probe. Materials and methods: Using a 150-nm aperture to heat an ethylene vinyl acetate (EVA) film, melted spots on the average of 400 nm in diameter are generated on the underlying target composed of a 20-nm gold-particle monolayer. The near-field tip probe composed of fiber is set on a 2-D nanometer piezoactuator (PZT) for precise capturing of the monolayer of gold particles.The monolayer of gold particles under the target is bound to the EVA film using a laser, while the remaining EVA film stays on the monolayer. Results: The diameter of the melted spots as small as 400 nm are produced and details are provided that demonstrate the feasibility of the nanooperation of this new LCMsystem. Conclusion: The new LCMsystem successfully captures nanoparticles and improves resolution of microdissection to 400 nm. With this LCM system, the isolation of a single organelle or bacterium is possible.

AB - Purpose: A modified laser capture microdissection (LCM) system is developed to improve resolution to 400 nm, using a laser light (808 nm) transmitted by a near-field tip probe. Materials and methods: Using a 150-nm aperture to heat an ethylene vinyl acetate (EVA) film, melted spots on the average of 400 nm in diameter are generated on the underlying target composed of a 20-nm gold-particle monolayer. The near-field tip probe composed of fiber is set on a 2-D nanometer piezoactuator (PZT) for precise capturing of the monolayer of gold particles.The monolayer of gold particles under the target is bound to the EVA film using a laser, while the remaining EVA film stays on the monolayer. Results: The diameter of the melted spots as small as 400 nm are produced and details are provided that demonstrate the feasibility of the nanooperation of this new LCMsystem. Conclusion: The new LCMsystem successfully captures nanoparticles and improves resolution of microdissection to 400 nm. With this LCM system, the isolation of a single organelle or bacterium is possible.

KW - Laser capturemicrodissection (LCM)

KW - Nanooperation

KW - Near-field fiber probe

UR - http://www.scopus.com/inward/record.url?scp=68949094508&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=68949094508&partnerID=8YFLogxK

U2 - 10.1109/TNB.2009.2019698

DO - 10.1109/TNB.2009.2019698

M3 - Article

C2 - 19336290

AN - SCOPUS:68949094508

VL - 8

SP - 113

EP - 119

JO - IEEE Transactions on Nanobioscience

JF - IEEE Transactions on Nanobioscience

SN - 1536-1241

IS - 2

M1 - 4806083

ER -