Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T

Ming Long Wu, Pei Hsin Wu, Teng Yi Huang, Yi Yu Shih, Ming Chung Chou, Hua Shan Liu, Hsiao Wen Chung, Cheng Yu Chen

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

The steady-state free precession (SSFP) method has been shown to exhibit strong potential for distortion-free functional magnetic resonance imaging (fMRI). One major challenge of SSFP fMRI is that the frequency band corresponding to the highest functional sensitivity is extremely narrow, leading to substantial loss of functional contrast in the presence of magnetic field drifts. In this study we propose a frequency stabilization scheme whereby an RF pulse with small flip angle is applied before each image scan, and the initial phase of the free induction decay (FID) signals is extracted to reflect temporal field drifts. A simple infinite impulse response (IIR) filter is further employed to obtain a low-pass-filtered estimate of the central reference frequency for the upcoming scan. Experimental results suggest that the proposed scheme can stabilize the frequency settings in accordance with field drifts, with oscillation amplitudes of

Original languageEnglish
Pages (from-to)369-379
Number of pages11
JournalMagnetic Resonance in Medicine
Volume57
Issue number2
DOIs
Publication statusPublished - Feb 2007
Externally publishedYes

Fingerprint

Magnetic Resonance Imaging
Magnetic Fields

Keywords

  • Balanced steady-state free precession
  • Blood oxygenation-sensitive steady state
  • Frequency stabilization
  • Functional magnetic resonance imaging
  • IIR filter

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T. / Wu, Ming Long; Wu, Pei Hsin; Huang, Teng Yi; Shih, Yi Yu; Chou, Ming Chung; Liu, Hua Shan; Chung, Hsiao Wen; Chen, Cheng Yu.

In: Magnetic Resonance in Medicine, Vol. 57, No. 2, 02.2007, p. 369-379.

Research output: Contribution to journalArticle

Wu, Ming Long ; Wu, Pei Hsin ; Huang, Teng Yi ; Shih, Yi Yu ; Chou, Ming Chung ; Liu, Hua Shan ; Chung, Hsiao Wen ; Chen, Cheng Yu. / Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T. In: Magnetic Resonance in Medicine. 2007 ; Vol. 57, No. 2. pp. 369-379.
@article{9e39c2baa67e40938e1e04ee4c0d8c45,
title = "Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T",
abstract = "The steady-state free precession (SSFP) method has been shown to exhibit strong potential for distortion-free functional magnetic resonance imaging (fMRI). One major challenge of SSFP fMRI is that the frequency band corresponding to the highest functional sensitivity is extremely narrow, leading to substantial loss of functional contrast in the presence of magnetic field drifts. In this study we propose a frequency stabilization scheme whereby an RF pulse with small flip angle is applied before each image scan, and the initial phase of the free induction decay (FID) signals is extracted to reflect temporal field drifts. A simple infinite impulse response (IIR) filter is further employed to obtain a low-pass-filtered estimate of the central reference frequency for the upcoming scan. Experimental results suggest that the proposed scheme can stabilize the frequency settings in accordance with field drifts, with oscillation amplitudes of",
keywords = "Balanced steady-state free precession, Blood oxygenation-sensitive steady state, Frequency stabilization, Functional magnetic resonance imaging, IIR filter",
author = "Wu, {Ming Long} and Wu, {Pei Hsin} and Huang, {Teng Yi} and Shih, {Yi Yu} and Chou, {Ming Chung} and Liu, {Hua Shan} and Chung, {Hsiao Wen} and Chen, {Cheng Yu}",
year = "2007",
month = "2",
doi = "10.1002/mrm.21138",
language = "English",
volume = "57",
pages = "369--379",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T

AU - Wu, Ming Long

AU - Wu, Pei Hsin

AU - Huang, Teng Yi

AU - Shih, Yi Yu

AU - Chou, Ming Chung

AU - Liu, Hua Shan

AU - Chung, Hsiao Wen

AU - Chen, Cheng Yu

PY - 2007/2

Y1 - 2007/2

N2 - The steady-state free precession (SSFP) method has been shown to exhibit strong potential for distortion-free functional magnetic resonance imaging (fMRI). One major challenge of SSFP fMRI is that the frequency band corresponding to the highest functional sensitivity is extremely narrow, leading to substantial loss of functional contrast in the presence of magnetic field drifts. In this study we propose a frequency stabilization scheme whereby an RF pulse with small flip angle is applied before each image scan, and the initial phase of the free induction decay (FID) signals is extracted to reflect temporal field drifts. A simple infinite impulse response (IIR) filter is further employed to obtain a low-pass-filtered estimate of the central reference frequency for the upcoming scan. Experimental results suggest that the proposed scheme can stabilize the frequency settings in accordance with field drifts, with oscillation amplitudes of

AB - The steady-state free precession (SSFP) method has been shown to exhibit strong potential for distortion-free functional magnetic resonance imaging (fMRI). One major challenge of SSFP fMRI is that the frequency band corresponding to the highest functional sensitivity is extremely narrow, leading to substantial loss of functional contrast in the presence of magnetic field drifts. In this study we propose a frequency stabilization scheme whereby an RF pulse with small flip angle is applied before each image scan, and the initial phase of the free induction decay (FID) signals is extracted to reflect temporal field drifts. A simple infinite impulse response (IIR) filter is further employed to obtain a low-pass-filtered estimate of the central reference frequency for the upcoming scan. Experimental results suggest that the proposed scheme can stabilize the frequency settings in accordance with field drifts, with oscillation amplitudes of

KW - Balanced steady-state free precession

KW - Blood oxygenation-sensitive steady state

KW - Frequency stabilization

KW - Functional magnetic resonance imaging

KW - IIR filter

UR - http://www.scopus.com/inward/record.url?scp=33846839591&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846839591&partnerID=8YFLogxK

U2 - 10.1002/mrm.21138

DO - 10.1002/mrm.21138

M3 - Article

VL - 57

SP - 369

EP - 379

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -