台北市長期照護機構生物性環境暴露評估

Translated title of the contribution: Exposure Assessment of Biological Contaminants in Five Long-Term Care Facilities in Taipei, Taiwan

吳 欣橋(Hsin-Chiao Wu), Hsing-Jasmine Chao, Ruey-Yu Chen, 張 振平(Cheng-Ping Chang), 于 台珊(Tai-Shan Yu)

Research output: Contribution to journalArticle

Abstract

We investigated five long-term care facilities in Taipei, Taiwan to determine the distribution of biological contaminants and to assess worker' exposure to these contaminants. A one-week intensive environmental sampling was performed at each study facility. We mouitored culturable fungi and bacteria in indoor air, near AC (air conditioning) diffusers, and outdoors as well as temperature, relative humidity, and CO2 levels. Facilities D and E had the highest (1444.32 CFU/m^3) and lowest (426.69 CFU/m^3) fungal concentrations respectively among the study facilities. Facilities C and D had higher bacterial levels (811.83 CFU/m^3 and 802.42 CFU/m^3, respectively) than other study facilities, and facility E had the lowest bacterial level (282.12 CFU /m^3). Based on the multiple regression analyses, fungal levels were associated with relative humidity, sampling time, and building age; bacterial concentrations correlated with CO2 levels, number of people, and facilities. In summary, biological exposure in long-term care facilities mainly results from inadequate environment and AC/HVAC (Heating, Ventilating and Air Conditioning) system cleaning and insufficient ventilation rates. Therefore, better AC/HVAC (Heating, V'entilating and Air Conditioning) cleaning and proper ventilation should be implemented in long term care facilities to decrease the biological exposure of residents and workers.
Original languageTraditional Chinese
Pages (from-to)138-145
Number of pages8
Journal勞工安全衛生研究季刊
Volume15
Issue number2
Publication statusPublished - Jun 1 2007

Fingerprint

air conditioning
pollutant
ventilation
relative humidity
heating
sampling
indoor air
multiple regression
exposure
fungus
bacterium
temperature

Keywords

  • Long-term care facilities
  • Exposure assessment
  • Occupational health
  • Culturable fungi
  • Culturable bacteria

Cite this

吳欣橋(Hsin-Chiao W, Chao, H-J., Chen, R-Y., 張振平(Cheng-Ping C, & 于台珊(Tai-Shan Y (2007). 台北市長期照護機構生物性環境暴露評估. 勞工安全衛生研究季刊, 15(2), 138-145.

台北市長期照護機構生物性環境暴露評估. / 吳欣橋(Hsin-Chiao Wu); Chao, Hsing-Jasmine; Chen, Ruey-Yu; 張振平(Cheng-Ping Chang); 于台珊(Tai-Shan Yu).

In: 勞工安全衛生研究季刊, Vol. 15, No. 2, 01.06.2007, p. 138-145.

Research output: Contribution to journalArticle

吳欣橋(Hsin-ChiaoW, Chao, H-J, Chen, R-Y, 張振平(Cheng-PingC & 于台珊(Tai-ShanY 2007, '台北市長期照護機構生物性環境暴露評估', 勞工安全衛生研究季刊, vol. 15, no. 2, pp. 138-145.
吳欣橋(Hsin-ChiaoW, Chao H-J, Chen R-Y, 張振平(Cheng-PingC, 于台珊(Tai-ShanY. 台北市長期照護機構生物性環境暴露評估. 勞工安全衛生研究季刊. 2007 Jun 1;15(2):138-145.
吳欣橋(Hsin-Chiao Wu) ; Chao, Hsing-Jasmine ; Chen, Ruey-Yu ; 張振平(Cheng-Ping Chang) ; 于台珊(Tai-Shan Yu). / 台北市長期照護機構生物性環境暴露評估. In: 勞工安全衛生研究季刊. 2007 ; Vol. 15, No. 2. pp. 138-145.
@article{2f419019f0f74063b638b76023d642c8,
title = "台北市長期照護機構生物性環境暴露評估",
abstract = "本研究針對台北市長期照護機構進行環境暴露評估,以瞭解工作環境中生物性污染物的分佈情形及員工暴露狀況。我們針對五家同意參與計畫之長期照護機構分別進行一個星期的密集環境採樣,採樣項目包括室內空氣中、空調通風系統出風口、以及室外空氣中的可培養性真菌和細菌,採樣同時並測量溫度、相對濕度和二氧化碳濃度。根據研究結果發現,室內平均總真菌濃度最高及最低的機構分別是機構D(1444.32 CFU/立方公尺)及機構B (426.69 CFU/立方公尺);室內平均總細菌濃度較高的為機構C(811.83 CFU/立方公尺)及D(802.42 CFU/立方公尺),最低的為機構E(282.12 CFU/立方公尺)。根據多變項迴歸分析,真菌濃度與相對濕度、上午或下午採樣、以及建築年齡有顯著相關,而細菌濃度則與二氧化碳濃度、採樣點人數、以及機構別有顯著相關。綜合研究結果發現,長期照護機構的生物性暴露主要應是環境及空調通風系統清潔不佳,以及通風量過低所致。因此建議長期照護機構應有完善的環境清潔程序及計畫,並且提供機構內各區域適當的戶外新鮮空氣,以降低員工及住民的生物性暴露。",
keywords = "長期照護機構, 暴露評估, 職業衛生, 可培養性真菌, 可培養性細菌, Long-term care facilities, Exposure assessment, Occupational health , Culturable fungi, Culturable bacteria",
author = "吳, {欣橋(Hsin-Chiao Wu)} and Hsing-Jasmine Chao and Ruey-Yu Chen and 張, {振平(Cheng-Ping Chang)} and 于, {台珊(Tai-Shan Yu)}",
year = "2007",
month = "6",
day = "1",
language = "繁體中文",
volume = "15",
pages = "138--145",
journal = "勞工安全衛生研究季刊",
issn = "1024-9877",
publisher = "行政院勞工委員會勞工安全衛生研究所",
number = "2",

}

TY - JOUR

T1 - 台北市長期照護機構生物性環境暴露評估

AU - 吳, 欣橋(Hsin-Chiao Wu)

AU - Chao, Hsing-Jasmine

AU - Chen, Ruey-Yu

AU - 張, 振平(Cheng-Ping Chang)

AU - 于, 台珊(Tai-Shan Yu)

PY - 2007/6/1

Y1 - 2007/6/1

N2 - 本研究針對台北市長期照護機構進行環境暴露評估,以瞭解工作環境中生物性污染物的分佈情形及員工暴露狀況。我們針對五家同意參與計畫之長期照護機構分別進行一個星期的密集環境採樣,採樣項目包括室內空氣中、空調通風系統出風口、以及室外空氣中的可培養性真菌和細菌,採樣同時並測量溫度、相對濕度和二氧化碳濃度。根據研究結果發現,室內平均總真菌濃度最高及最低的機構分別是機構D(1444.32 CFU/立方公尺)及機構B (426.69 CFU/立方公尺);室內平均總細菌濃度較高的為機構C(811.83 CFU/立方公尺)及D(802.42 CFU/立方公尺),最低的為機構E(282.12 CFU/立方公尺)。根據多變項迴歸分析,真菌濃度與相對濕度、上午或下午採樣、以及建築年齡有顯著相關,而細菌濃度則與二氧化碳濃度、採樣點人數、以及機構別有顯著相關。綜合研究結果發現,長期照護機構的生物性暴露主要應是環境及空調通風系統清潔不佳,以及通風量過低所致。因此建議長期照護機構應有完善的環境清潔程序及計畫,並且提供機構內各區域適當的戶外新鮮空氣,以降低員工及住民的生物性暴露。

AB - 本研究針對台北市長期照護機構進行環境暴露評估,以瞭解工作環境中生物性污染物的分佈情形及員工暴露狀況。我們針對五家同意參與計畫之長期照護機構分別進行一個星期的密集環境採樣,採樣項目包括室內空氣中、空調通風系統出風口、以及室外空氣中的可培養性真菌和細菌,採樣同時並測量溫度、相對濕度和二氧化碳濃度。根據研究結果發現,室內平均總真菌濃度最高及最低的機構分別是機構D(1444.32 CFU/立方公尺)及機構B (426.69 CFU/立方公尺);室內平均總細菌濃度較高的為機構C(811.83 CFU/立方公尺)及D(802.42 CFU/立方公尺),最低的為機構E(282.12 CFU/立方公尺)。根據多變項迴歸分析,真菌濃度與相對濕度、上午或下午採樣、以及建築年齡有顯著相關,而細菌濃度則與二氧化碳濃度、採樣點人數、以及機構別有顯著相關。綜合研究結果發現,長期照護機構的生物性暴露主要應是環境及空調通風系統清潔不佳,以及通風量過低所致。因此建議長期照護機構應有完善的環境清潔程序及計畫,並且提供機構內各區域適當的戶外新鮮空氣,以降低員工及住民的生物性暴露。

KW - 長期照護機構

KW - 暴露評估

KW - 職業衛生

KW - 可培養性真菌

KW - 可培養性細菌

KW - Long-term care facilities

KW - Exposure assessment

KW - Occupational health

KW - Culturable fungi

KW - Culturable bacteria

M3 - 文章

VL - 15

SP - 138

EP - 145

JO - 勞工安全衛生研究季刊

JF - 勞工安全衛生研究季刊

SN - 1024-9877

IS - 2

ER -