Effects of two surface finishes on the color of cemented and colored anatomic-contour zirconia crowns

Wei Fang Lee, Sheng-Wei Feng, Yi Jie Lu, Hsin Jui Wu, Pei Wen Peng

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Statement of problem: The esthetic appearance of anatomic-contour zirconia restorations is influenced by the shade of the coloring liquid and the optical properties of the luting cements. However, few studies are available on the effects of surface-finishing methods and luting cements on colored anatomic-contour zirconia restorations. Purpose: The purpose of this in vitro study was to investigate the effects of surface finishing methods on the color distribution of colored anatomic-contour zirconia crowns before and after being cemented onto abutments. Material and methods: Implant-supported anatomic-contour zirconia premolar crowns were fabricated and immersed in A3-coloring liquid for 30 seconds. The colored zirconia crowns were separated into 3 groups according to the method of surface treatment: no treatment (N), polishing (P), and glazing (G). The zirconia crowns without coloring liquid application served as the control group. CIELab color coordinates were obtained, and color differences (δE) between shaded crowns were calculated with a spectrophotometer. The color stability of the crown before and after cement application was also investigated. Results: Before cement application, the mean color difference between groups N and P was 2.85 δE units, whereas the mean δE value between groups N and G was 3.27. Mean δE values with and without cement application among groups ranged from 2.75 to 3.45 δE units. Conclusions: The color appearance of the colored zirconia crowns was strongly influenced by the surface-finishing methods and luting cement application.

Original languageEnglish
JournalJournal of Prosthetic Dentistry
DOIs
Publication statusAccepted/In press - 2016

Fingerprint

Crowns
Color
Bicuspid
zirconium oxide
Esthetics
Control Groups

ASJC Scopus subject areas

  • Oral Surgery

Cite this

@article{8c12ea16361447f6b3780dd492178bf7,
title = "Effects of two surface finishes on the color of cemented and colored anatomic-contour zirconia crowns",
abstract = "Statement of problem: The esthetic appearance of anatomic-contour zirconia restorations is influenced by the shade of the coloring liquid and the optical properties of the luting cements. However, few studies are available on the effects of surface-finishing methods and luting cements on colored anatomic-contour zirconia restorations. Purpose: The purpose of this in vitro study was to investigate the effects of surface finishing methods on the color distribution of colored anatomic-contour zirconia crowns before and after being cemented onto abutments. Material and methods: Implant-supported anatomic-contour zirconia premolar crowns were fabricated and immersed in A3-coloring liquid for 30 seconds. The colored zirconia crowns were separated into 3 groups according to the method of surface treatment: no treatment (N), polishing (P), and glazing (G). The zirconia crowns without coloring liquid application served as the control group. CIELab color coordinates were obtained, and color differences (δE) between shaded crowns were calculated with a spectrophotometer. The color stability of the crown before and after cement application was also investigated. Results: Before cement application, the mean color difference between groups N and P was 2.85 δE units, whereas the mean δE value between groups N and G was 3.27. Mean δE values with and without cement application among groups ranged from 2.75 to 3.45 δE units. Conclusions: The color appearance of the colored zirconia crowns was strongly influenced by the surface-finishing methods and luting cement application.",
author = "Lee, {Wei Fang} and Sheng-Wei Feng and Lu, {Yi Jie} and Wu, {Hsin Jui} and Peng, {Pei Wen}",
year = "2016",
doi = "10.1016/j.prosdent.2015.12.012",
language = "English",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",

}

TY - JOUR

T1 - Effects of two surface finishes on the color of cemented and colored anatomic-contour zirconia crowns

AU - Lee, Wei Fang

AU - Feng, Sheng-Wei

AU - Lu, Yi Jie

AU - Wu, Hsin Jui

AU - Peng, Pei Wen

PY - 2016

Y1 - 2016

N2 - Statement of problem: The esthetic appearance of anatomic-contour zirconia restorations is influenced by the shade of the coloring liquid and the optical properties of the luting cements. However, few studies are available on the effects of surface-finishing methods and luting cements on colored anatomic-contour zirconia restorations. Purpose: The purpose of this in vitro study was to investigate the effects of surface finishing methods on the color distribution of colored anatomic-contour zirconia crowns before and after being cemented onto abutments. Material and methods: Implant-supported anatomic-contour zirconia premolar crowns were fabricated and immersed in A3-coloring liquid for 30 seconds. The colored zirconia crowns were separated into 3 groups according to the method of surface treatment: no treatment (N), polishing (P), and glazing (G). The zirconia crowns without coloring liquid application served as the control group. CIELab color coordinates were obtained, and color differences (δE) between shaded crowns were calculated with a spectrophotometer. The color stability of the crown before and after cement application was also investigated. Results: Before cement application, the mean color difference between groups N and P was 2.85 δE units, whereas the mean δE value between groups N and G was 3.27. Mean δE values with and without cement application among groups ranged from 2.75 to 3.45 δE units. Conclusions: The color appearance of the colored zirconia crowns was strongly influenced by the surface-finishing methods and luting cement application.

AB - Statement of problem: The esthetic appearance of anatomic-contour zirconia restorations is influenced by the shade of the coloring liquid and the optical properties of the luting cements. However, few studies are available on the effects of surface-finishing methods and luting cements on colored anatomic-contour zirconia restorations. Purpose: The purpose of this in vitro study was to investigate the effects of surface finishing methods on the color distribution of colored anatomic-contour zirconia crowns before and after being cemented onto abutments. Material and methods: Implant-supported anatomic-contour zirconia premolar crowns were fabricated and immersed in A3-coloring liquid for 30 seconds. The colored zirconia crowns were separated into 3 groups according to the method of surface treatment: no treatment (N), polishing (P), and glazing (G). The zirconia crowns without coloring liquid application served as the control group. CIELab color coordinates were obtained, and color differences (δE) between shaded crowns were calculated with a spectrophotometer. The color stability of the crown before and after cement application was also investigated. Results: Before cement application, the mean color difference between groups N and P was 2.85 δE units, whereas the mean δE value between groups N and G was 3.27. Mean δE values with and without cement application among groups ranged from 2.75 to 3.45 δE units. Conclusions: The color appearance of the colored zirconia crowns was strongly influenced by the surface-finishing methods and luting cement application.

UR - http://www.scopus.com/inward/record.url?scp=84962140499&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962140499&partnerID=8YFLogxK

U2 - 10.1016/j.prosdent.2015.12.012

DO - 10.1016/j.prosdent.2015.12.012

M3 - Article

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

ER -