Effect of cooling on electrical field stimulation and norepinephrine-induced contraction in isolated hypertrophic human nasal mucosa

Yueng Hsiang Chu, Chin Chen Wu, Hsing Won Wang

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Background: Exposure to cold causes cutaneous vasoconstriction to reduce body heat loss, while the nasal cavity warms up the inspired cold air. This suggests cooling might evoke a different response in nasal mucosa blood vessels than in cutaneous blood vessels. Thus, the aim of this study was to evaluate the effect of cooling (to 24°C) on the vascular response of isolated nasal mucosa. Methods: An in vitro isometric contraction of nasal mucosa excised from patients suffered from chronic nasal congestion was continuously recorded. Either electrical field stimulation (EFS) or exogenous norepinephrine (NE) was applied to the turbinate mucosa strip at 37 and 24°C, and the influence of cooling (to 24°C) was evaluated. Results: EFS (1, 2, 4, and 8 Hz) produced frequency-dependent contractions at 37 and 24°C. Cooling did not alter the magnitude but significantly prolonged the duration of EFS-induced contraction. Exogenous NE (10 -8 to 10 -4 M) produced concentration-dependent contractions at 37 and 24°C. Cooling significantly enhanced the contractile responses evoked by NE between 3 × 10 -6 and 1 × 10 -4 M. Conclusion: Cooling (to 24°C) prolonged the EFS-induced and enhanced NE (3 × 10 -6 to 1 × 10 -4 M)-induced contraction of isolated human nasal mucosa.

Original languageEnglish
Pages (from-to)471-475
Number of pages5
JournalAmerican Journal of Rhinology
Volume20
Issue number5
DOIs
Publication statusPublished - Sep 2006
Externally publishedYes

Fingerprint

Nasal Mucosa
Electric Stimulation
Norepinephrine
Blood Vessels
Turbinates
Skin
Isometric Contraction
Nasal Cavity
Vasoconstriction
Nose
Mucous Membrane
Hot Temperature
Air

ASJC Scopus subject areas

  • Otorhinolaryngology

Cite this

Effect of cooling on electrical field stimulation and norepinephrine-induced contraction in isolated hypertrophic human nasal mucosa. / Chu, Yueng Hsiang; Wu, Chin Chen; Wang, Hsing Won.

In: American Journal of Rhinology, Vol. 20, No. 5, 09.2006, p. 471-475.

Research output: Contribution to journalArticle

@article{786dc2f2ba194dd18c244e9ea5fe7bf7,
title = "Effect of cooling on electrical field stimulation and norepinephrine-induced contraction in isolated hypertrophic human nasal mucosa",
abstract = "Background: Exposure to cold causes cutaneous vasoconstriction to reduce body heat loss, while the nasal cavity warms up the inspired cold air. This suggests cooling might evoke a different response in nasal mucosa blood vessels than in cutaneous blood vessels. Thus, the aim of this study was to evaluate the effect of cooling (to 24°C) on the vascular response of isolated nasal mucosa. Methods: An in vitro isometric contraction of nasal mucosa excised from patients suffered from chronic nasal congestion was continuously recorded. Either electrical field stimulation (EFS) or exogenous norepinephrine (NE) was applied to the turbinate mucosa strip at 37 and 24°C, and the influence of cooling (to 24°C) was evaluated. Results: EFS (1, 2, 4, and 8 Hz) produced frequency-dependent contractions at 37 and 24°C. Cooling did not alter the magnitude but significantly prolonged the duration of EFS-induced contraction. Exogenous NE (10 -8 to 10 -4 M) produced concentration-dependent contractions at 37 and 24°C. Cooling significantly enhanced the contractile responses evoked by NE between 3 × 10 -6 and 1 × 10 -4 M. Conclusion: Cooling (to 24°C) prolonged the EFS-induced and enhanced NE (3 × 10 -6 to 1 × 10 -4 M)-induced contraction of isolated human nasal mucosa.",
author = "Chu, {Yueng Hsiang} and Wu, {Chin Chen} and Wang, {Hsing Won}",
year = "2006",
month = "9",
doi = "10.2500/ajr.2006.20.2942",
language = "English",
volume = "20",
pages = "471--475",
journal = "American Journal of Rhinology and Allergy",
issn = "1945-8924",
publisher = "OceanSide Publications Inc.",
number = "5",

}

TY - JOUR

T1 - Effect of cooling on electrical field stimulation and norepinephrine-induced contraction in isolated hypertrophic human nasal mucosa

AU - Chu, Yueng Hsiang

AU - Wu, Chin Chen

AU - Wang, Hsing Won

PY - 2006/9

Y1 - 2006/9

N2 - Background: Exposure to cold causes cutaneous vasoconstriction to reduce body heat loss, while the nasal cavity warms up the inspired cold air. This suggests cooling might evoke a different response in nasal mucosa blood vessels than in cutaneous blood vessels. Thus, the aim of this study was to evaluate the effect of cooling (to 24°C) on the vascular response of isolated nasal mucosa. Methods: An in vitro isometric contraction of nasal mucosa excised from patients suffered from chronic nasal congestion was continuously recorded. Either electrical field stimulation (EFS) or exogenous norepinephrine (NE) was applied to the turbinate mucosa strip at 37 and 24°C, and the influence of cooling (to 24°C) was evaluated. Results: EFS (1, 2, 4, and 8 Hz) produced frequency-dependent contractions at 37 and 24°C. Cooling did not alter the magnitude but significantly prolonged the duration of EFS-induced contraction. Exogenous NE (10 -8 to 10 -4 M) produced concentration-dependent contractions at 37 and 24°C. Cooling significantly enhanced the contractile responses evoked by NE between 3 × 10 -6 and 1 × 10 -4 M. Conclusion: Cooling (to 24°C) prolonged the EFS-induced and enhanced NE (3 × 10 -6 to 1 × 10 -4 M)-induced contraction of isolated human nasal mucosa.

AB - Background: Exposure to cold causes cutaneous vasoconstriction to reduce body heat loss, while the nasal cavity warms up the inspired cold air. This suggests cooling might evoke a different response in nasal mucosa blood vessels than in cutaneous blood vessels. Thus, the aim of this study was to evaluate the effect of cooling (to 24°C) on the vascular response of isolated nasal mucosa. Methods: An in vitro isometric contraction of nasal mucosa excised from patients suffered from chronic nasal congestion was continuously recorded. Either electrical field stimulation (EFS) or exogenous norepinephrine (NE) was applied to the turbinate mucosa strip at 37 and 24°C, and the influence of cooling (to 24°C) was evaluated. Results: EFS (1, 2, 4, and 8 Hz) produced frequency-dependent contractions at 37 and 24°C. Cooling did not alter the magnitude but significantly prolonged the duration of EFS-induced contraction. Exogenous NE (10 -8 to 10 -4 M) produced concentration-dependent contractions at 37 and 24°C. Cooling significantly enhanced the contractile responses evoked by NE between 3 × 10 -6 and 1 × 10 -4 M. Conclusion: Cooling (to 24°C) prolonged the EFS-induced and enhanced NE (3 × 10 -6 to 1 × 10 -4 M)-induced contraction of isolated human nasal mucosa.

UR - http://www.scopus.com/inward/record.url?scp=33750061299&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750061299&partnerID=8YFLogxK

U2 - 10.2500/ajr.2006.20.2942

DO - 10.2500/ajr.2006.20.2942

M3 - Article

C2 - 17063740

AN - SCOPUS:33750061299

VL - 20

SP - 471

EP - 475

JO - American Journal of Rhinology and Allergy

JF - American Journal of Rhinology and Allergy

SN - 1945-8924

IS - 5

ER -