Effect of collagen on the mechanical properties of hydroxyapatite coatings

Keng Liang Ou, Ren Jei Chung, Fu Yi Tsai, Pei Yu Liang, Shih Wei Huang, Shou Yi Chang

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

In this study, the mechanical properties of bioactive coatings on Ti6Al4V substrates were investigated using instrumented nanoindentation. The aim was to observe the differences in the mechanical properties before and after immersion in collagen solution. The hydroxyapatite coatings were prepared through two processes: self-assembly in simulated body fluid and a hydrothermal method. Sintered hydroxyapatite disks were used as controls. The test samples were then incubated in a dilute collagen solution for 24 hours to produce composite coatings. The materials were investigated using XRD, SEM and nanoindentation. The results showed that the grain sizes of the hydroxyapatite coatings formed using two processes were 1 μm and 10 μm, respectively. The Young's modulus of the pure hydroxyapatite, the disk and the coatings, was 3.6 GPa. After collagen incubation treatment, the composites had a Young's modulus of 7.5 GPa. The results also showed that the strengthening phenomena of collagen were more obvious for homogeneous and small-grain hydroxyapatite coatings. These results suggest that there are similarities between these HAp/collagen composited and natural composite materials, such as teeth and bones.

Original languageEnglish
Pages (from-to)618-624
Number of pages7
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume4
Issue number4
DOIs
Publication statusPublished - May 2011

Fingerprint

Durapatite
Hydroxyapatite
Collagen
Coatings
Mechanical properties
Nanoindentation
Elastic moduli
Composite coatings
Body fluids
Composite materials
Self assembly
Bone
Scanning electron microscopy
Substrates

Keywords

  • Collagen
  • Hydroxyapatite coatings
  • Mechanical properties
  • Nanoindentation

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering
  • Mechanics of Materials

Cite this

Effect of collagen on the mechanical properties of hydroxyapatite coatings. / Ou, Keng Liang; Chung, Ren Jei; Tsai, Fu Yi; Liang, Pei Yu; Huang, Shih Wei; Chang, Shou Yi.

In: Journal of the Mechanical Behavior of Biomedical Materials, Vol. 4, No. 4, 05.2011, p. 618-624.

Research output: Contribution to journalArticle

Ou, Keng Liang ; Chung, Ren Jei ; Tsai, Fu Yi ; Liang, Pei Yu ; Huang, Shih Wei ; Chang, Shou Yi. / Effect of collagen on the mechanical properties of hydroxyapatite coatings. In: Journal of the Mechanical Behavior of Biomedical Materials. 2011 ; Vol. 4, No. 4. pp. 618-624.
@article{7f7976d49ee247efb8084ed8ce4801f1,
title = "Effect of collagen on the mechanical properties of hydroxyapatite coatings",
abstract = "In this study, the mechanical properties of bioactive coatings on Ti6Al4V substrates were investigated using instrumented nanoindentation. The aim was to observe the differences in the mechanical properties before and after immersion in collagen solution. The hydroxyapatite coatings were prepared through two processes: self-assembly in simulated body fluid and a hydrothermal method. Sintered hydroxyapatite disks were used as controls. The test samples were then incubated in a dilute collagen solution for 24 hours to produce composite coatings. The materials were investigated using XRD, SEM and nanoindentation. The results showed that the grain sizes of the hydroxyapatite coatings formed using two processes were 1 μm and 10 μm, respectively. The Young's modulus of the pure hydroxyapatite, the disk and the coatings, was 3.6 GPa. After collagen incubation treatment, the composites had a Young's modulus of 7.5 GPa. The results also showed that the strengthening phenomena of collagen were more obvious for homogeneous and small-grain hydroxyapatite coatings. These results suggest that there are similarities between these HAp/collagen composited and natural composite materials, such as teeth and bones.",
keywords = "Collagen, Hydroxyapatite coatings, Mechanical properties, Nanoindentation",
author = "Ou, {Keng Liang} and Chung, {Ren Jei} and Tsai, {Fu Yi} and Liang, {Pei Yu} and Huang, {Shih Wei} and Chang, {Shou Yi}",
year = "2011",
month = "5",
doi = "10.1016/j.jmbbm.2011.02.001",
language = "English",
volume = "4",
pages = "618--624",
journal = "Journal of the Mechanical Behavior of Biomedical Materials",
issn = "1751-6161",
publisher = "Elsevier BV",
number = "4",

}

TY - JOUR

T1 - Effect of collagen on the mechanical properties of hydroxyapatite coatings

AU - Ou, Keng Liang

AU - Chung, Ren Jei

AU - Tsai, Fu Yi

AU - Liang, Pei Yu

AU - Huang, Shih Wei

AU - Chang, Shou Yi

PY - 2011/5

Y1 - 2011/5

N2 - In this study, the mechanical properties of bioactive coatings on Ti6Al4V substrates were investigated using instrumented nanoindentation. The aim was to observe the differences in the mechanical properties before and after immersion in collagen solution. The hydroxyapatite coatings were prepared through two processes: self-assembly in simulated body fluid and a hydrothermal method. Sintered hydroxyapatite disks were used as controls. The test samples were then incubated in a dilute collagen solution for 24 hours to produce composite coatings. The materials were investigated using XRD, SEM and nanoindentation. The results showed that the grain sizes of the hydroxyapatite coatings formed using two processes were 1 μm and 10 μm, respectively. The Young's modulus of the pure hydroxyapatite, the disk and the coatings, was 3.6 GPa. After collagen incubation treatment, the composites had a Young's modulus of 7.5 GPa. The results also showed that the strengthening phenomena of collagen were more obvious for homogeneous and small-grain hydroxyapatite coatings. These results suggest that there are similarities between these HAp/collagen composited and natural composite materials, such as teeth and bones.

AB - In this study, the mechanical properties of bioactive coatings on Ti6Al4V substrates were investigated using instrumented nanoindentation. The aim was to observe the differences in the mechanical properties before and after immersion in collagen solution. The hydroxyapatite coatings were prepared through two processes: self-assembly in simulated body fluid and a hydrothermal method. Sintered hydroxyapatite disks were used as controls. The test samples were then incubated in a dilute collagen solution for 24 hours to produce composite coatings. The materials were investigated using XRD, SEM and nanoindentation. The results showed that the grain sizes of the hydroxyapatite coatings formed using two processes were 1 μm and 10 μm, respectively. The Young's modulus of the pure hydroxyapatite, the disk and the coatings, was 3.6 GPa. After collagen incubation treatment, the composites had a Young's modulus of 7.5 GPa. The results also showed that the strengthening phenomena of collagen were more obvious for homogeneous and small-grain hydroxyapatite coatings. These results suggest that there are similarities between these HAp/collagen composited and natural composite materials, such as teeth and bones.

KW - Collagen

KW - Hydroxyapatite coatings

KW - Mechanical properties

KW - Nanoindentation

UR - http://www.scopus.com/inward/record.url?scp=79952485103&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79952485103&partnerID=8YFLogxK

U2 - 10.1016/j.jmbbm.2011.02.001

DO - 10.1016/j.jmbbm.2011.02.001

M3 - Article

C2 - 21396611

AN - SCOPUS:79952485103

VL - 4

SP - 618

EP - 624

JO - Journal of the Mechanical Behavior of Biomedical Materials

JF - Journal of the Mechanical Behavior of Biomedical Materials

SN - 1751-6161

IS - 4

ER -