Early diagnosis of osteoarthritis using cathepsin B sensitive near-infrared fluorescent probes

Wen Fu T Lai, Chung Hsun Chang, Yi Tang, Roederick Bronson, Ching Hsuan Tung

Research output: Contribution to journalArticle

64 Citations (Scopus)

Abstract

Objective: Osteoarthritis is currently diagnosed utilizing X-ray and MRI-techniques, both of which are based on the morphological changes of tissue. However, once changes are detected, the tissue has an irreversible defect. This study investigates early diagnosis of OA on a molecular basis using a recently developed cathepsin B sensitive near-infrared (NIR) fluorescent probe, Method: Twelve male nude mice were induced osteoarthritis by intra-articular injection of collagenase (1.0%, w/v) into the right knee joint. The left knee joint served as the negative control. The cathepsin B NIR probe is activated by arthritis-associated cathepsin B, thus resulting in the emission of an intensive NIR fluorescence signal which can be detected in vivo. NIR fluorescence signals were acquired on an optical imaging system using an excitation wavelength of 610-650 nm and an emission wavelength of 680-720 nm. Results: Mild to moderate degenerative cartilage was observed 1 month after collagenase injection. NIR fluorescence imaging of mice showed approximately a 3-fold difference in signal intensity between osteoarthritic and normal joints 24 h after intravenous injection of the reporter probe. Immunohistochemical evaluation also revealed cathepsin B expression in the arthritic lesion of femorotibia joints, and not in the control contra-lateral knee joints. Conclusion: As the cathepsin B activatable NIR fluorescent imaging showed a significant difference between the osteoarthritic and normal joints, the cathepsin B activatable NIR fluorescent probe thus offers a potential new imaging technology for early OA diagnosis.

Original languageEnglish
Pages (from-to)239-244
Number of pages6
JournalOsteoarthritis and Cartilage
Volume12
Issue number3
DOIs
Publication statusPublished - Mar 2004

Fingerprint

Cathepsin B
Fluorescent Dyes
Osteoarthritis
Early Diagnosis
Infrared radiation
Knee Joint
Joints
Optical Imaging
Collagenases
Fluorescence
Arthritis
Imaging techniques
Intra-Articular Injections
Optical Devices
Tissue
Wavelength
Nude Mice
Intravenous Injections
Cartilage
Cathepsins

Keywords

  • Cathepsin B
  • Collagenase
  • Imaging
  • Near-infrared fluorescence
  • Osteoarthritis

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Early diagnosis of osteoarthritis using cathepsin B sensitive near-infrared fluorescent probes. / Lai, Wen Fu T; Chang, Chung Hsun; Tang, Yi; Bronson, Roederick; Tung, Ching Hsuan.

In: Osteoarthritis and Cartilage, Vol. 12, No. 3, 03.2004, p. 239-244.

Research output: Contribution to journalArticle

Lai, Wen Fu T ; Chang, Chung Hsun ; Tang, Yi ; Bronson, Roederick ; Tung, Ching Hsuan. / Early diagnosis of osteoarthritis using cathepsin B sensitive near-infrared fluorescent probes. In: Osteoarthritis and Cartilage. 2004 ; Vol. 12, No. 3. pp. 239-244.
@article{07aaa0d56fcc4c6db1f6d9b5a4160698,
title = "Early diagnosis of osteoarthritis using cathepsin B sensitive near-infrared fluorescent probes",
abstract = "Objective: Osteoarthritis is currently diagnosed utilizing X-ray and MRI-techniques, both of which are based on the morphological changes of tissue. However, once changes are detected, the tissue has an irreversible defect. This study investigates early diagnosis of OA on a molecular basis using a recently developed cathepsin B sensitive near-infrared (NIR) fluorescent probe, Method: Twelve male nude mice were induced osteoarthritis by intra-articular injection of collagenase (1.0{\%}, w/v) into the right knee joint. The left knee joint served as the negative control. The cathepsin B NIR probe is activated by arthritis-associated cathepsin B, thus resulting in the emission of an intensive NIR fluorescence signal which can be detected in vivo. NIR fluorescence signals were acquired on an optical imaging system using an excitation wavelength of 610-650 nm and an emission wavelength of 680-720 nm. Results: Mild to moderate degenerative cartilage was observed 1 month after collagenase injection. NIR fluorescence imaging of mice showed approximately a 3-fold difference in signal intensity between osteoarthritic and normal joints 24 h after intravenous injection of the reporter probe. Immunohistochemical evaluation also revealed cathepsin B expression in the arthritic lesion of femorotibia joints, and not in the control contra-lateral knee joints. Conclusion: As the cathepsin B activatable NIR fluorescent imaging showed a significant difference between the osteoarthritic and normal joints, the cathepsin B activatable NIR fluorescent probe thus offers a potential new imaging technology for early OA diagnosis.",
keywords = "Cathepsin B, Collagenase, Imaging, Near-infrared fluorescence, Osteoarthritis",
author = "Lai, {Wen Fu T} and Chang, {Chung Hsun} and Yi Tang and Roederick Bronson and Tung, {Ching Hsuan}",
year = "2004",
month = "3",
doi = "10.1016/j.joca.2003.11.005",
language = "English",
volume = "12",
pages = "239--244",
journal = "Osteoarthritis and Cartilage",
issn = "1063-4584",
publisher = "W.B. Saunders Ltd",
number = "3",

}

TY - JOUR

T1 - Early diagnosis of osteoarthritis using cathepsin B sensitive near-infrared fluorescent probes

AU - Lai, Wen Fu T

AU - Chang, Chung Hsun

AU - Tang, Yi

AU - Bronson, Roederick

AU - Tung, Ching Hsuan

PY - 2004/3

Y1 - 2004/3

N2 - Objective: Osteoarthritis is currently diagnosed utilizing X-ray and MRI-techniques, both of which are based on the morphological changes of tissue. However, once changes are detected, the tissue has an irreversible defect. This study investigates early diagnosis of OA on a molecular basis using a recently developed cathepsin B sensitive near-infrared (NIR) fluorescent probe, Method: Twelve male nude mice were induced osteoarthritis by intra-articular injection of collagenase (1.0%, w/v) into the right knee joint. The left knee joint served as the negative control. The cathepsin B NIR probe is activated by arthritis-associated cathepsin B, thus resulting in the emission of an intensive NIR fluorescence signal which can be detected in vivo. NIR fluorescence signals were acquired on an optical imaging system using an excitation wavelength of 610-650 nm and an emission wavelength of 680-720 nm. Results: Mild to moderate degenerative cartilage was observed 1 month after collagenase injection. NIR fluorescence imaging of mice showed approximately a 3-fold difference in signal intensity between osteoarthritic and normal joints 24 h after intravenous injection of the reporter probe. Immunohistochemical evaluation also revealed cathepsin B expression in the arthritic lesion of femorotibia joints, and not in the control contra-lateral knee joints. Conclusion: As the cathepsin B activatable NIR fluorescent imaging showed a significant difference between the osteoarthritic and normal joints, the cathepsin B activatable NIR fluorescent probe thus offers a potential new imaging technology for early OA diagnosis.

AB - Objective: Osteoarthritis is currently diagnosed utilizing X-ray and MRI-techniques, both of which are based on the morphological changes of tissue. However, once changes are detected, the tissue has an irreversible defect. This study investigates early diagnosis of OA on a molecular basis using a recently developed cathepsin B sensitive near-infrared (NIR) fluorescent probe, Method: Twelve male nude mice were induced osteoarthritis by intra-articular injection of collagenase (1.0%, w/v) into the right knee joint. The left knee joint served as the negative control. The cathepsin B NIR probe is activated by arthritis-associated cathepsin B, thus resulting in the emission of an intensive NIR fluorescence signal which can be detected in vivo. NIR fluorescence signals were acquired on an optical imaging system using an excitation wavelength of 610-650 nm and an emission wavelength of 680-720 nm. Results: Mild to moderate degenerative cartilage was observed 1 month after collagenase injection. NIR fluorescence imaging of mice showed approximately a 3-fold difference in signal intensity between osteoarthritic and normal joints 24 h after intravenous injection of the reporter probe. Immunohistochemical evaluation also revealed cathepsin B expression in the arthritic lesion of femorotibia joints, and not in the control contra-lateral knee joints. Conclusion: As the cathepsin B activatable NIR fluorescent imaging showed a significant difference between the osteoarthritic and normal joints, the cathepsin B activatable NIR fluorescent probe thus offers a potential new imaging technology for early OA diagnosis.

KW - Cathepsin B

KW - Collagenase

KW - Imaging

KW - Near-infrared fluorescence

KW - Osteoarthritis

UR - http://www.scopus.com/inward/record.url?scp=1342304427&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1342304427&partnerID=8YFLogxK

U2 - 10.1016/j.joca.2003.11.005

DO - 10.1016/j.joca.2003.11.005

M3 - Article

C2 - 14972341

AN - SCOPUS:1342304427

VL - 12

SP - 239

EP - 244

JO - Osteoarthritis and Cartilage

JF - Osteoarthritis and Cartilage

SN - 1063-4584

IS - 3

ER -