Abstract

The direct air-liquid interface (ALI) in vitro exposure method are used for high-throughput screening of nanoparticle toxicity, due to the relatively low capital required and the low cost of labor compared to animal and in vivo experiments. In this study, a new ALI exposure chamber using an electrostatic precipitator (ESP-ALI) was designed to improve the nano- and submicron-sized particle collection efficiency on the air-liquid exposure interface. Particle penetration tests were performed to characterize the performance under different operating conditions. The effects of different geometric dimensions and operating conditions were explored, and the similarity-scaling process was applied to reveal the hidden effects underlying the experimental data. The penetration results show that the developed electrostatic precipitator is able to efficiently collect particles with a size of up to 300. nm under a DC electric field of 5.0. kV/cm and at a flow rate of up to 1.5. lpm. The electrospray charging technique was also tested with this ESP-ALI system and proved to enhance the ALI collection efficiency without ozone generation. In addition, the particles collected on the exposure interface are uniformly distributed under various operating conditions, as supported by consistent dimensionless precipitation densities.

Original languageEnglish
Pages (from-to)1-9
JournalJournal of the Taiwan Institute of Chemical Engineers
Volume72
DOIs
Publication statusPublished - Mar 1 2017

Fingerprint

Electrostatic precipitators
Aerosols
Toxicity
Liquids
Air
Ozone
Screening
Animals
Electric fields
Flow rate
Throughput
Personnel
Nanoparticles
Costs
Experiments

Keywords

  • Air-liquid interface
  • Dosimetry
  • Electrospray
  • Electrostatic precipitator (ESP)
  • Nanoparticle exposure

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Development and collection efficiency of an electrostatic precipitator for in-vitro toxicity studies of nano- and submicron-sized aerosols. / Hsiao, Ta Chih; Chuang, Hsiao Chi; Chen, Chun Wan; Cheng, Tsun Jen; Chang Chien, Ya Chien.

In: Journal of the Taiwan Institute of Chemical Engineers, Vol. 72, 01.03.2017, p. 1-9.

Research output: Contribution to journalArticle

@article{36a8070b361945ad83a85ef59065a61a,
title = "Development and collection efficiency of an electrostatic precipitator for in-vitro toxicity studies of nano- and submicron-sized aerosols",
abstract = "The direct air-liquid interface (ALI) in vitro exposure method are used for high-throughput screening of nanoparticle toxicity, due to the relatively low capital required and the low cost of labor compared to animal and in vivo experiments. In this study, a new ALI exposure chamber using an electrostatic precipitator (ESP-ALI) was designed to improve the nano- and submicron-sized particle collection efficiency on the air-liquid exposure interface. Particle penetration tests were performed to characterize the performance under different operating conditions. The effects of different geometric dimensions and operating conditions were explored, and the similarity-scaling process was applied to reveal the hidden effects underlying the experimental data. The penetration results show that the developed electrostatic precipitator is able to efficiently collect particles with a size of up to 300. nm under a DC electric field of 5.0. kV/cm and at a flow rate of up to 1.5. lpm. The electrospray charging technique was also tested with this ESP-ALI system and proved to enhance the ALI collection efficiency without ozone generation. In addition, the particles collected on the exposure interface are uniformly distributed under various operating conditions, as supported by consistent dimensionless precipitation densities.",
keywords = "Air-liquid interface, Dosimetry, Electrospray, Electrostatic precipitator (ESP), Nanoparticle exposure",
author = "Hsiao, {Ta Chih} and Chuang, {Hsiao Chi} and Chen, {Chun Wan} and Cheng, {Tsun Jen} and {Chang Chien}, {Ya Chien}",
year = "2017",
month = "3",
day = "1",
doi = "10.1016/j.jtice.2017.01.003",
language = "English",
volume = "72",
pages = "1--9",
journal = "Journal of the Taiwan Institute of Chemical Engineers",
issn = "1876-1070",
publisher = "Taiwan Institute of Chemical Engineers",

}

TY - JOUR

T1 - Development and collection efficiency of an electrostatic precipitator for in-vitro toxicity studies of nano- and submicron-sized aerosols

AU - Hsiao, Ta Chih

AU - Chuang, Hsiao Chi

AU - Chen, Chun Wan

AU - Cheng, Tsun Jen

AU - Chang Chien, Ya Chien

PY - 2017/3/1

Y1 - 2017/3/1

N2 - The direct air-liquid interface (ALI) in vitro exposure method are used for high-throughput screening of nanoparticle toxicity, due to the relatively low capital required and the low cost of labor compared to animal and in vivo experiments. In this study, a new ALI exposure chamber using an electrostatic precipitator (ESP-ALI) was designed to improve the nano- and submicron-sized particle collection efficiency on the air-liquid exposure interface. Particle penetration tests were performed to characterize the performance under different operating conditions. The effects of different geometric dimensions and operating conditions were explored, and the similarity-scaling process was applied to reveal the hidden effects underlying the experimental data. The penetration results show that the developed electrostatic precipitator is able to efficiently collect particles with a size of up to 300. nm under a DC electric field of 5.0. kV/cm and at a flow rate of up to 1.5. lpm. The electrospray charging technique was also tested with this ESP-ALI system and proved to enhance the ALI collection efficiency without ozone generation. In addition, the particles collected on the exposure interface are uniformly distributed under various operating conditions, as supported by consistent dimensionless precipitation densities.

AB - The direct air-liquid interface (ALI) in vitro exposure method are used for high-throughput screening of nanoparticle toxicity, due to the relatively low capital required and the low cost of labor compared to animal and in vivo experiments. In this study, a new ALI exposure chamber using an electrostatic precipitator (ESP-ALI) was designed to improve the nano- and submicron-sized particle collection efficiency on the air-liquid exposure interface. Particle penetration tests were performed to characterize the performance under different operating conditions. The effects of different geometric dimensions and operating conditions were explored, and the similarity-scaling process was applied to reveal the hidden effects underlying the experimental data. The penetration results show that the developed electrostatic precipitator is able to efficiently collect particles with a size of up to 300. nm under a DC electric field of 5.0. kV/cm and at a flow rate of up to 1.5. lpm. The electrospray charging technique was also tested with this ESP-ALI system and proved to enhance the ALI collection efficiency without ozone generation. In addition, the particles collected on the exposure interface are uniformly distributed under various operating conditions, as supported by consistent dimensionless precipitation densities.

KW - Air-liquid interface

KW - Dosimetry

KW - Electrospray

KW - Electrostatic precipitator (ESP)

KW - Nanoparticle exposure

UR - http://www.scopus.com/inward/record.url?scp=85011074106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85011074106&partnerID=8YFLogxK

U2 - 10.1016/j.jtice.2017.01.003

DO - 10.1016/j.jtice.2017.01.003

M3 - Article

AN - SCOPUS:85011074106

VL - 72

SP - 1

EP - 9

JO - Journal of the Taiwan Institute of Chemical Engineers

JF - Journal of the Taiwan Institute of Chemical Engineers

SN - 1876-1070

ER -