Development and Application of a Versatile FES System

Shih Ching Chen, Jer Junn Luh, Yu Luen Chen, Cheng Liang Liu, Chung Huang Yu, Han Chang Wu, Chun Hao Chen, Yasunobu Handa, Shuenn Tsong Young, Te Son Kuo, Jin Shin Lai

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The purpose of this study was to develop a versatile Functional Electrical Stimulation (FES) system and to perform clinical applications to restore the functions of decentralized and paralyzed limbs. The development of the electrical stimulator, core of the FES system, is based on the element-envelope method. A direct-synthesized arbitrary waveform is generated by a digital signal processor, and bi-phasic, voltage-controlled, constant current stimuli are provided by an analog output circuit. The pattern generators receive the commands, coming from a patient-driven input device or a closed-loop feedback sensing device, to synthesize the required waveforms and elicit the required functions. In clinical application, a pedal cycling FES system, a patient-driven hand grasping FES system with a closed-loop feedback controller and an ankle motion FES system with a neural network and fuzzy controller were tested. The results showed that the proposed stimulator could be considered as a full-featured electrical stimulator for various FES applications with its flexibility in pattern generation and feedback processing capabilities. All of the clinical applications showed satisfactory results in the restoration and control of some specific functions.

Original languageEnglish
Pages (from-to)37-43
Number of pages7
JournalJournal of Medical and Biological Engineering
Volume24
Issue number1
Publication statusPublished - Mar 2004

Fingerprint

Electric Stimulation
Feedback
Controllers
Digital signal processors
Restoration
Equipment and Supplies
Neural networks
Ankle
Networks (circuits)
Foot
Electric potential
Extremities
Hand
Processing

Keywords

  • Ankle motion
  • Constant current
  • Feedback control
  • Functional electrical stimulation (FES)
  • Hand grasping
  • Pedal cycling

ASJC Scopus subject areas

  • Biophysics

Cite this

Chen, S. C., Luh, J. J., Chen, Y. L., Liu, C. L., Yu, C. H., Wu, H. C., ... Lai, J. S. (2004). Development and Application of a Versatile FES System. Journal of Medical and Biological Engineering, 24(1), 37-43.

Development and Application of a Versatile FES System. / Chen, Shih Ching; Luh, Jer Junn; Chen, Yu Luen; Liu, Cheng Liang; Yu, Chung Huang; Wu, Han Chang; Chen, Chun Hao; Handa, Yasunobu; Young, Shuenn Tsong; Kuo, Te Son; Lai, Jin Shin.

In: Journal of Medical and Biological Engineering, Vol. 24, No. 1, 03.2004, p. 37-43.

Research output: Contribution to journalArticle

Chen, SC, Luh, JJ, Chen, YL, Liu, CL, Yu, CH, Wu, HC, Chen, CH, Handa, Y, Young, ST, Kuo, TS & Lai, JS 2004, 'Development and Application of a Versatile FES System', Journal of Medical and Biological Engineering, vol. 24, no. 1, pp. 37-43.
Chen SC, Luh JJ, Chen YL, Liu CL, Yu CH, Wu HC et al. Development and Application of a Versatile FES System. Journal of Medical and Biological Engineering. 2004 Mar;24(1):37-43.
Chen, Shih Ching ; Luh, Jer Junn ; Chen, Yu Luen ; Liu, Cheng Liang ; Yu, Chung Huang ; Wu, Han Chang ; Chen, Chun Hao ; Handa, Yasunobu ; Young, Shuenn Tsong ; Kuo, Te Son ; Lai, Jin Shin. / Development and Application of a Versatile FES System. In: Journal of Medical and Biological Engineering. 2004 ; Vol. 24, No. 1. pp. 37-43.
@article{84d21e370ba04057a4cb3ecef28e28f6,
title = "Development and Application of a Versatile FES System",
abstract = "The purpose of this study was to develop a versatile Functional Electrical Stimulation (FES) system and to perform clinical applications to restore the functions of decentralized and paralyzed limbs. The development of the electrical stimulator, core of the FES system, is based on the element-envelope method. A direct-synthesized arbitrary waveform is generated by a digital signal processor, and bi-phasic, voltage-controlled, constant current stimuli are provided by an analog output circuit. The pattern generators receive the commands, coming from a patient-driven input device or a closed-loop feedback sensing device, to synthesize the required waveforms and elicit the required functions. In clinical application, a pedal cycling FES system, a patient-driven hand grasping FES system with a closed-loop feedback controller and an ankle motion FES system with a neural network and fuzzy controller were tested. The results showed that the proposed stimulator could be considered as a full-featured electrical stimulator for various FES applications with its flexibility in pattern generation and feedback processing capabilities. All of the clinical applications showed satisfactory results in the restoration and control of some specific functions.",
keywords = "Ankle motion, Constant current, Feedback control, Functional electrical stimulation (FES), Hand grasping, Pedal cycling",
author = "Chen, {Shih Ching} and Luh, {Jer Junn} and Chen, {Yu Luen} and Liu, {Cheng Liang} and Yu, {Chung Huang} and Wu, {Han Chang} and Chen, {Chun Hao} and Yasunobu Handa and Young, {Shuenn Tsong} and Kuo, {Te Son} and Lai, {Jin Shin}",
year = "2004",
month = "3",
language = "English",
volume = "24",
pages = "37--43",
journal = "Journal of Medical and Biological Engineering",
issn = "1609-0985",
publisher = "中華民國生物醫學工程學會",
number = "1",

}

TY - JOUR

T1 - Development and Application of a Versatile FES System

AU - Chen, Shih Ching

AU - Luh, Jer Junn

AU - Chen, Yu Luen

AU - Liu, Cheng Liang

AU - Yu, Chung Huang

AU - Wu, Han Chang

AU - Chen, Chun Hao

AU - Handa, Yasunobu

AU - Young, Shuenn Tsong

AU - Kuo, Te Son

AU - Lai, Jin Shin

PY - 2004/3

Y1 - 2004/3

N2 - The purpose of this study was to develop a versatile Functional Electrical Stimulation (FES) system and to perform clinical applications to restore the functions of decentralized and paralyzed limbs. The development of the electrical stimulator, core of the FES system, is based on the element-envelope method. A direct-synthesized arbitrary waveform is generated by a digital signal processor, and bi-phasic, voltage-controlled, constant current stimuli are provided by an analog output circuit. The pattern generators receive the commands, coming from a patient-driven input device or a closed-loop feedback sensing device, to synthesize the required waveforms and elicit the required functions. In clinical application, a pedal cycling FES system, a patient-driven hand grasping FES system with a closed-loop feedback controller and an ankle motion FES system with a neural network and fuzzy controller were tested. The results showed that the proposed stimulator could be considered as a full-featured electrical stimulator for various FES applications with its flexibility in pattern generation and feedback processing capabilities. All of the clinical applications showed satisfactory results in the restoration and control of some specific functions.

AB - The purpose of this study was to develop a versatile Functional Electrical Stimulation (FES) system and to perform clinical applications to restore the functions of decentralized and paralyzed limbs. The development of the electrical stimulator, core of the FES system, is based on the element-envelope method. A direct-synthesized arbitrary waveform is generated by a digital signal processor, and bi-phasic, voltage-controlled, constant current stimuli are provided by an analog output circuit. The pattern generators receive the commands, coming from a patient-driven input device or a closed-loop feedback sensing device, to synthesize the required waveforms and elicit the required functions. In clinical application, a pedal cycling FES system, a patient-driven hand grasping FES system with a closed-loop feedback controller and an ankle motion FES system with a neural network and fuzzy controller were tested. The results showed that the proposed stimulator could be considered as a full-featured electrical stimulator for various FES applications with its flexibility in pattern generation and feedback processing capabilities. All of the clinical applications showed satisfactory results in the restoration and control of some specific functions.

KW - Ankle motion

KW - Constant current

KW - Feedback control

KW - Functional electrical stimulation (FES)

KW - Hand grasping

KW - Pedal cycling

UR - http://www.scopus.com/inward/record.url?scp=11144354210&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=11144354210&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:11144354210

VL - 24

SP - 37

EP - 43

JO - Journal of Medical and Biological Engineering

JF - Journal of Medical and Biological Engineering

SN - 1609-0985

IS - 1

ER -