Abstract

An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2% chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5%. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10%. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits.

Original languageEnglish
Pages (from-to)379-382
Number of pages4
JournalJournal of Chromatography B: Biomedical Applications
Volume685
Issue number2
DOIs
Publication statusPublished - Oct 25 1996

Fingerprint

High performance liquid chromatography
Plasmas
Chloroform
Pharmacokinetics
Solvent extraction
Silicon Dioxide
Organic solvents
butylidenephthalide
Assays
Recovery

Keywords

  • Z-Butylidenephthalide

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Determination of Z-butylidenephthalide in plasma by high-performance liquid chromatography. / Ko, Wun Chang; Yang, Jen Y.; Chen, Chi Ming.

In: Journal of Chromatography B: Biomedical Applications, Vol. 685, No. 2, 25.10.1996, p. 379-382.

Research output: Contribution to journalArticle

@article{40b371b199844c8ca227777184f3f1cb,
title = "Determination of Z-butylidenephthalide in plasma by high-performance liquid chromatography",
abstract = "An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2{\%} chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5{\%}. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10{\%}. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits.",
keywords = "Z-Butylidenephthalide",
author = "Ko, {Wun Chang} and Yang, {Jen Y.} and Chen, {Chi Ming}",
year = "1996",
month = "10",
day = "25",
doi = "10.1016/S0378-4347(96)00201-0",
language = "English",
volume = "685",
pages = "379--382",
journal = "Journal of Chromatography B: Biomedical Sciences and Applications",
issn = "0378-4347",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Determination of Z-butylidenephthalide in plasma by high-performance liquid chromatography

AU - Ko, Wun Chang

AU - Yang, Jen Y.

AU - Chen, Chi Ming

PY - 1996/10/25

Y1 - 1996/10/25

N2 - An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2% chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5%. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10%. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits.

AB - An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2% chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5%. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10%. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits.

KW - Z-Butylidenephthalide

UR - http://www.scopus.com/inward/record.url?scp=0030601648&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030601648&partnerID=8YFLogxK

U2 - 10.1016/S0378-4347(96)00201-0

DO - 10.1016/S0378-4347(96)00201-0

M3 - Article

VL - 685

SP - 379

EP - 382

JO - Journal of Chromatography B: Biomedical Sciences and Applications

JF - Journal of Chromatography B: Biomedical Sciences and Applications

SN - 0378-4347

IS - 2

ER -