Determination of transdermal sildenafil in nude mouse skin by reversed-phase high-performance liquid chromatography

Jiahorng Liaw, Ting Wei Chang

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

A simple and sensitive high-performance liquid chromatographic method was developed for the determination of sildenafil transdermal permeation of nude mouse skin. A reversed-phase column with UV detection at 224 nm was used for chromatographic separation. The mobile phase consisted of 32% acetonitrile with 0.2% phosphoric acid in water at pH 5.3 adjusted with 10 M NaOH with the flow-rate set at 1.0 ml/min. The limit of quantitation achieved was 5 ng/ml, and the calibration curve showed good linearity over the concentration range of 5-500 ng/ml. The relative standard deviations of within- and between-day analyses were all within 15%. Sildenafil was found to be stable between pH 3 and 12 during 24-h incubation with skin. After transdermal administration of 15.8 μg/ml of sildenafil to nude mouse skin, it was detected as early as 15 min. The transport amount of sildenafil could be quantitated and, at pH 8-11, had the highest permeation rate in nude mouse skin.

Original languageEnglish
Pages (from-to)161-166
Number of pages6
JournalJournal of Chromatography B: Biomedical Sciences and Applications
Volume765
Issue number2
DOIs
Publication statusPublished - Dec 25 2001

Fingerprint

High performance liquid chromatography
Skin
Permeation
Flow rate
Calibration
Sildenafil Citrate
Water
Liquids

Keywords

  • Permeability
  • Sildenafil
  • Transdermal

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

@article{d443e1d1c5274a8ebab8f4513f1a3e1b,
title = "Determination of transdermal sildenafil in nude mouse skin by reversed-phase high-performance liquid chromatography",
abstract = "A simple and sensitive high-performance liquid chromatographic method was developed for the determination of sildenafil transdermal permeation of nude mouse skin. A reversed-phase column with UV detection at 224 nm was used for chromatographic separation. The mobile phase consisted of 32{\%} acetonitrile with 0.2{\%} phosphoric acid in water at pH 5.3 adjusted with 10 M NaOH with the flow-rate set at 1.0 ml/min. The limit of quantitation achieved was 5 ng/ml, and the calibration curve showed good linearity over the concentration range of 5-500 ng/ml. The relative standard deviations of within- and between-day analyses were all within 15{\%}. Sildenafil was found to be stable between pH 3 and 12 during 24-h incubation with skin. After transdermal administration of 15.8 μg/ml of sildenafil to nude mouse skin, it was detected as early as 15 min. The transport amount of sildenafil could be quantitated and, at pH 8-11, had the highest permeation rate in nude mouse skin.",
keywords = "Permeability, Sildenafil, Transdermal",
author = "Jiahorng Liaw and Chang, {Ting Wei}",
year = "2001",
month = "12",
day = "25",
doi = "10.1016/S0378-4347(01)00421-2",
language = "English",
volume = "765",
pages = "161--166",
journal = "Journal of Chromatography B: Biomedical Sciences and Applications",
issn = "0378-4347",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Determination of transdermal sildenafil in nude mouse skin by reversed-phase high-performance liquid chromatography

AU - Liaw, Jiahorng

AU - Chang, Ting Wei

PY - 2001/12/25

Y1 - 2001/12/25

N2 - A simple and sensitive high-performance liquid chromatographic method was developed for the determination of sildenafil transdermal permeation of nude mouse skin. A reversed-phase column with UV detection at 224 nm was used for chromatographic separation. The mobile phase consisted of 32% acetonitrile with 0.2% phosphoric acid in water at pH 5.3 adjusted with 10 M NaOH with the flow-rate set at 1.0 ml/min. The limit of quantitation achieved was 5 ng/ml, and the calibration curve showed good linearity over the concentration range of 5-500 ng/ml. The relative standard deviations of within- and between-day analyses were all within 15%. Sildenafil was found to be stable between pH 3 and 12 during 24-h incubation with skin. After transdermal administration of 15.8 μg/ml of sildenafil to nude mouse skin, it was detected as early as 15 min. The transport amount of sildenafil could be quantitated and, at pH 8-11, had the highest permeation rate in nude mouse skin.

AB - A simple and sensitive high-performance liquid chromatographic method was developed for the determination of sildenafil transdermal permeation of nude mouse skin. A reversed-phase column with UV detection at 224 nm was used for chromatographic separation. The mobile phase consisted of 32% acetonitrile with 0.2% phosphoric acid in water at pH 5.3 adjusted with 10 M NaOH with the flow-rate set at 1.0 ml/min. The limit of quantitation achieved was 5 ng/ml, and the calibration curve showed good linearity over the concentration range of 5-500 ng/ml. The relative standard deviations of within- and between-day analyses were all within 15%. Sildenafil was found to be stable between pH 3 and 12 during 24-h incubation with skin. After transdermal administration of 15.8 μg/ml of sildenafil to nude mouse skin, it was detected as early as 15 min. The transport amount of sildenafil could be quantitated and, at pH 8-11, had the highest permeation rate in nude mouse skin.

KW - Permeability

KW - Sildenafil

KW - Transdermal

UR - http://www.scopus.com/inward/record.url?scp=0035951027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035951027&partnerID=8YFLogxK

U2 - 10.1016/S0378-4347(01)00421-2

DO - 10.1016/S0378-4347(01)00421-2

M3 - Article

C2 - 11767309

AN - SCOPUS:0035951027

VL - 765

SP - 161

EP - 166

JO - Journal of Chromatography B: Biomedical Sciences and Applications

JF - Journal of Chromatography B: Biomedical Sciences and Applications

SN - 0378-4347

IS - 2

ER -